mooreplc can provide both factory new and surplus SINAMICS drives and accessories.
 



mooreplc can provide both factory new and surplus SINAMICS drives and accessories.
 

special remind


if you don't find the control system components that you need from our website . 
please do not hestitate to contact us . 
we can help you to find new or refurbished control system parts according to your requirments.

The warranty of industry automation components and parts that "amikon" 1-year warranty.

Please click on the part number or image to view product details.
show:
26-50 of 325
< page 2 of 13 >
Siemens

Power block

SINAMICS Replacement power block 
for 510-750 V DC, 1405A
DC Voltage:510–750 V DC
Rated Current:1405 A

Siemens

Power block

SINAMICS Replacement power block 
for 380-480V 3AC, 50/60 Hz, 
745 A AC Drive/Power Module V and W phases 
Painted modules and nickel-plated busbars

Siemens

Fan transformer

SINAMICS replacement fan transformer 
for 500-690V 3AC
50/60 Hz basic line module 
Built-in unit design GB

Siemens

Fan transformer

SINAMICS replacement fan 
transformer for 500-690V 3AC
50/60 Hz Smart Line Module 
Built-in unit design H and J

Siemens

DRIVE BOARD

DRIVE BOARD
MWH
FOR CU2 CONTROL UNIT
SIMOVERT MASTERDRIVES

Siemens

INVERTER INPUT BOARD

Supply Voltage:+24 V DC
Number: 2 
Voltage range: 0–10 V or ±10 V
Current range: 4–20 mA
Input impedance: ≥ 100 kΩ
Number: 4
Logic level: 24 V DC 
Isolation:≥ 1500 Vrms

Siemens

PC BOARD MODULE

Control Inputs:0–10 V
Control‑Side Supply: +24 V DC
Digital I/O:24 V DC logic
Analog I/O:0–10 V
Edge‑card backplane interface
20‑pin low‑voltage I/O header
6‑pin gate‑driver output header

Siemens

SINGLE MOTOR MODULE

SINAMICS S120 
SINGLE MOTOR MODULE 
INPUT: DC 600V 
OUTPUT: 3AC 400V, 60A 
FRAME SIZE: BOOKSIZE C-TYPE 
INTERNAL AIR COOLING OPTIMIZED PULSE SAMPLE 
AND SUPPORT OF THE EXTENDED SAFETY 
INTEGRATED FUNCTIONS 
INCL. DRIVE-CLIQ CABLE

Siemens

VDU RESISTOR

VDU RESISTOR
180R OHM
10 PERCENT

Siemens

Power Driver Board

Input Voltag:15 V – 24 V DC typical
Peak Gate Current: 2 A – 5 A
Isolation Voltage: ≥ 2500 Vrms
Desaturation protection
Under-voltage lockout (UVLO)
Soft turn-off in fault condition
Short-circuit signal feedback

Siemens

Power Driver Board

Operating Voltage: 15 V – 24 V DC 
Peak output current: 2 – 5 A per channel
Isolation Voltage: ≥ 2500 Vrms
Operating Temperature: -10°C to +60°C
Storage Temperature: -25°C to +85°C
Relative Humidity: 5% – 95% (non-condensing)

Siemens

Current Transformer

Nominal Primary Current: 40 A
Nominal Secondary Current: 40 mA
Frequency Range: 0 – 500 Hz
Accuracy Class: Class 1
Rated Burden: ≤ 1 VA
Insulation Voltage: 800 V

Siemens

Power Interface Module

Power Interface 
incl. terminals C98043-A7106-L1 
Functional Safety

Siemens

Power output module

SIMOVERT Masterdrives 
power output module 
PEU5 for devices 6.1 A 
510-62 DC

Siemens

BRAKING RESISTOR

SINAMICS BRAKING RESISTOR 
INPUT: 600 V DC 
OUTPUT: 250KW/15S 200KW/20S 2.2 OHM

Siemens

INVERTER CONTROL MODULE

PC BOARD
INVERTER CONTROL MODULE
IGD8
FOR DEVICES 510-620 VDC
860A

Siemens

BRAKING UNIT

SINAMICS / SIMOVERT MASTERDRIVES 
BRAKING UNIT 510 -650 V DC
170 KW PROTECTION IP20 
DOCUMENTATION ON CD

Siemens

SMART LINE MODULE

SINAMICS LINE 
REACTOR FOR 5 KW 
SMART LINE MODULE 
INPUT: 3-PH 380-480 V
50/60 HZ

Siemens

TSE circuit module

TSE circuit module 
TSE4 For infeed units 
of design E 380-480 V 3 AC
50/60 Hz

Siemens

CONTROL INTERFACE BOARD

Mounting Type: Slot-in module 
Operating Voltage:24 V DC 
Operating: 0°C to +40°C
Storage: -25°C to +70°C

Siemens

CONTROL CARD

CONTROL CARD
CUCP-02

Siemens

CONTROL UNIT

SINAMICS S110 
CONTROL UNIT 
CU305 PN WITHPROFINET 
INTERFACE 
WITHOUT MEMORY CARD

Siemens

Power Drive Board

SIMOVERT MASTERDRIVES 
POWER CONTROLLER
POWER BD
3 PHASE
47 AMP
380-460 VAC

Siemens

Control board

Logic Supply:24 V DC for I/O circuits
Power Consumption:≤ 5 W 
I/O Interfaces:24 V DC
Isolation Rating:1.5 kV AC

Siemens

Frequency converter board

Repetitive Peak Off‑State Voltage:1 600 V DC
Average On‑State Current:460 A
Critical dI/dt:250 A/µs
Non‑Repetitive I²t:1 200 kA²·s
On‑State Voltage Drop:1.44 V 
Turn‑Off Time: ≤ 200 µs
Insulation Test Voltage:1.5 kV AC
Thermal Resistance:0.074 K/W

show:
26-50 of 325
< page 2 of 13 >
All product and service marks contained herein are the trademarks or service marks of their respective owners.