ACTIVE LINE MODULE
SINAMICS S120
ACTIVE LINE MODULE
INPUT: 3-PH380-480V, 50/60HZ
OUTPUT: 600 V DC, 549 A,
300KW
INTERNAL AIR COOLING INCL
DRIVE-CLIQCABLE
MPC4 machinery protection card
Number of inputs : 4 per MPC4 card
DC range : 0 to +20 V or 0 to −20 V
AC range : ±10 V max.
Common mode voltage range : −50 to +50 VC
MRR : >60 dB at 50 Hz
Crosstalk : −72 dB
Input impedance : 200 kΩ
DC signals : 0 to 25 mA
AC signals : ±8 mA max
4 Channel Relay Output Module
Channel-to-Channel: 1500 VAC
Field-to-System: Reinforced isolation :2500 VAC
Per Channel: 1–2 W
Total: ≤ 8 W
Operating Temperature: -40°C to +70°C (industrial-grade)
Storage Temperature: -50°C to +85°C
Humidity: 0–95% (non-condensing)
SINAMICS Control unit
The Power Module:DC 24 V
External power supply:DC 20 ... 29 V
Max. power consumption:2.00 A
Power loss 12.00 W
Number:2
Output (resistive load):DC 30 V, 0.5 A
Number 15
Switching level: 0→1 11 V
Switching level: 1→0 5 V
PowerFlex 753 AC Drive
Bulletin Number:PowerFlex 753 AC Drive
with Embedded I/O
Corrosive Gas Protection and Cooling Type:
Standard Protection, Forced Air
Voltage Class:400 VAC, 3 PH
Output Current:205 Amps, 110kW ND, 90kW HD
Enclosure Type:Open Type
Input Type:AC Input with Precharge, no DC Terminals
Frame Size:Frame 6
EMC Filtering Options:Filtered
CM jumper installed (preferred)
PowerFlex 753 AC Drive
Bulletin Number:PowerFlex 753 AC Drive
with Embedded I/O
Corrosive Gas Protection and Cooling Type
Standard Protection, Forced Air
Voltage Class:400 VAC, 3 PH
Output Current:205 Amps, 110kW ND, 90kW HD
Enclosure Type:Open Type
Input Type:AC Input with Precharge, no DC Terminals
Frame Size:Frame 6
EMC Filtering Options:Filtered
CM jumper installed (preferred)
PowerFlex 753 AC Drive
Bulletin Number:PowerFlex 753 AC Drive
with Embedded I/O
Corrosive Gas Protection and Cooling Type:
Standard Protection, Forced Air
Voltage Class:400 VAC, 3 PH
Output Current:170 Amps, 90kW ND, 75kW HD
Enclosure Type:Open Type
Input Type:AC Input with Precharge, no DC Terminals
Frame Size:Frame 6
EMC Filtering Options:Filtered
CM jumper installed (preferred)
PowerFlex 753 AC Drive
Bulletin Number:PowerFlex 753 AC Drive
with Embedded I/O
Corrosive Gas Protection and Cooling Type:
Standard Protection, Forced Air
Voltage Class:400 VAC, 3 PH
Output Current:170 Amps, 90kW ND, 75kW HD
Enclosure Type:Open Type
Input Type:AC Input with Precharge, no DC Terminals
Frame Size:Frame 6
EMC Filtering Options:Filtered
M jumper installed (preferred)
Dynamic Braking:DB Transistor
HIM Blank (No HIM)
PowerFlex 753 AC Drive
Bulletin Number:PowerFlex 753 AC Drive
with Embedded I/O
Corrosive Gas Protection and Cooling Type:
Standard Protection, Forced Air
Voltage Class:400 VAC, 3 PH
Output Current:140 Amps, 75kW ND, 55kW HD
Enclosure Type:Open Type
Input Type:AC Input with Precharge, no DC Terminals
Frame Size:Frame 6
EMC Filtering Options:Filtered
CM jumper installed (preferred)
Dynamic Braking:DB Transistor
PowerFlex 753 AC Drive
Bulletin Number:PowerFlex 753 AC Drive
with Embedded I/O
Corrosive Gas Protection and Cooling Type:
Standard Protection, Forced Air
Voltage Class:400 VAC, 3 PH
Output Current:140 Amps, 75kW ND, 55kW HD
Enclosure Type:Open Type
Input Type:AC Input with Precharge, no DC Terminals
Frame Size:Frame 6
EMC Filtering Options:Filtered
CM jumper installed (preferred)
Dynamic Braking:None
Control panel
Type: LCD or TFT color touchscreen
Operating Voltage: 24 VDC (±10%) or 110–230 VAC
Power Consumption: 10–20 W
Operating Temperature: -10°C to +55°C
Storage Temperature: -40°C to +70°C
Humidity: 5–95% (non-condensing)
FIRING PULSE TRANSFORMER BOARD
Model: SDCS-PIN-H41
Part Number: 3ADT320600R1501
Pulse Voltage: 5–24 V DC
Isolated Pulse Voltage: Typically 10–30 V
Output Current: 1–2 A
Primary-to-Secondary Isolation: ≥2500 V AC
Insulation Resistance: >100 MΩ
Armor ControlLogix Controller
Series:ControlLogix
Module Type:Armor ControlLogix Controller
Standard Memory:4 Megabytes
I/O Memory:0.98 Megabytes
Max Total I/O:128,000
Max Analog I/O:4000
Max Digital I/O:128,000
Ethernet Ports:4 Ethernet M12 Category 5E
USB Ports:USB 1.1 Full Speed (12 Mbps)
Nom Input Voltage:24 Volts DC
Input Voltage Range:18-32 Volts DC
Digital Input Module
Series:ControlLogix
Module Type:Isolated Digital Input Module
Inputs:16 Individually Isolated Inputs
Input Voltage:240 Volts AC
Operating Voltage Range:159-265 Volts AC
Input Delay Time:Programmable 9 or 18 milliseconds
ControlLogix Lithium Battery Assembly
Series:ControlLogix
Battery Type:Externally Mounted
Power Dissipation (Max):4.5 Watts
Mounting:Horizontal
Enclosure:Open
Backplane Current (5 Volts DC):10 amps
Backplane Current (24 Volts DC):2.8 Amps
DC Output Module
Series:ControlLogix
Module Type:Electronic Fused DC Output Module
Outputs:16-Point Electronically Fused
Voltage:12-24 Volts DC
Operating Voltage Range:10-30 Volts DC
Backplane Current at 5 Volts:250 milliamps
ControlLogix Diagnostic DC Output Module
Series:ControlLogix
Module Type:Diagnostic DC Output Module
Outputs:16-Point Diagnostic
Voltage:24 Volts DC Source
Operating Voltage Range:19.2-30 Volts DC
Maximum Output Current Rating-Point:2 Amps at
Power Dissipation (Max):3.3 Watts at 60 Celsius
ControlLogix Processor Module
Series:ControlLogix
Module Type:Processor Module
I-O Memory:0.98 MB
User Memory:8 MB
Maximum I-O:128,000
Maximum Analog I-O:4,000
Maximum Digital I-O:128,000
GuardLogix Controller
Series:ControlLogix
Module Type:GuardLogix Controller
I-O Memory:0.98 MB
User Memory:8 MB
Maximum I-O:128,000
Maximum Analog I-O:4,000
Maximum Digital I-O:128,000
ControlLogix Processor Module
Series:ControlLogix
Module Type:Processor Module
I-O Memory:0.98 MB
User Memory:4 MB
Maximum I-O:128,000
Maximum Analog I-O:4,000
Maximum Digital I-O:128,000
Current Draw (1.2 Volts DC):5 Miliamperes
Current Draw (5.1 Volts DC):800 milliamps
Power Dissipation:2.5 Watts
Thermal Dissipation:8.5 BTU per hour
Isolation Voltage:30 Volts Continuous
ControlLogix Analog module
Series:ControlLogix
Part Number:1756-IT16
Application:Enhanced I/O for advanced control
Module type:Analog input, thermocouple mode
Number of channels:16, non-isolated
Data resolution:24-bit
Enclosure type:None (Open-style)
Mounting:Chassis
Variable speed drive
Easy Altivar 610
Variable speed drive
Fan, pump, compressor, conveyor
ATV610
Standard version
Cabinet mount
Bus Interface Unit
Series:Field Control
Manufacturer:GE Fanuc
Part Number:IC670GBI002D
Series:Field I/O control
Type:Bus interface unit
Part Number:IC670GBI002
CPU Redundancy:Supported
Supply Voltage range:18-30 VDC
Nominal supply voltage:24 VDC
Frequency:47 to 63 Hertz
Power consumption:16.8 Watts
Power Supply Output:6.5 VDC ±5%
PowerFlex 753 AC Drive
AC DRIVE
AIR COOLED
POWERFLEX 753
AC INPUT WITH PRECHARGE
IP54
NEMA TYPE 12
690 VAC / 932 VDC
200 KW / 268 HP
212 AMP
FILTERING
JUMPER INSTALLED
NO INTERNAL TRANSISTOR
PowerFlex 753 AC Drive
AC DRIVE
AIR COOLED
POWERFLEX 753
AC INPUT WITH PRECHARGE
IP54
NEMA TYPE 12
600 VAC / 810 VDC
185 KW / 250 HP
242 AMP
FILTERING
JUMPER REMOVED
NO INTERNAL TRANSISTOR
NO HIM
Copyright Notice © 2004-2024 amikong.com All rights reserved
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.