I/O Pack processor board
Processor Type:Mark VI
Backplane Power: +5 VDC
Analog: ±10 V, 4–20 mA
Digital: 24 V DC
Processing Speed: 100–200 MHz
Non-Volatile Memory (Flash):16–64 MB
Safe loop-monitored digital output module
Ability to de-energizel
Ability to de-energize via secondary meansl
Cross talk between outputsl
Function of the suppression diodesl
Lead breakage in the (external) output wiringl
Short circuit of the outputs
3300 XL 8 mm Proximity Probes
330101 3300 XL 8 mm Probe
3/8-24 UNFthread, without armor
Minimum unthreaded length: 0.0 in
Minimum case length: 2.5 in
10 1.0 meter (3.3 feet)
02 Miniature coaxial ClickLocconnector
standard cable
00 Not required
3300 XL 8 mm Proximity Probes
330101 3300 XL 8 mm Probe
3/8-24 UNFthread, without armor
Minimum unthreaded length: 0.0 in
Minimum case length: 1.8 in
10 1.0 meter (3.3 feet)
12 Miniature coaxial ClickLocconnector
FluidLoc cable
00 Not required
Velomitor CT
00 No stud
00 MIL-C-5015 connection interface
05 CSA/NRTL/C
Velomitor CT Transducer
3300 NSv Proximity Probes
330901 3300 NSv Probe
1/4-28 UNF thread,without armor
Minimum unthreaded length: 2.2 in
Minimum case length: 4.0 in
10 1.0 meter (39 in)
01Miniature coaxial ClickLoc connector
with connector protector, standardcable
05 Multiple Approvals
Analog Input Module
Points:32, commoned
Nominal input current:4–20 mA DC
Operational current range:2–22 mA DC
Absolute maximum field voltage:33 V DC
Absolute maximum reverse field voltage:– 0.6 V DC
Absolute maximum input current:50 mA DC
Input bandwidth (3dB):16 Hz
Source impedance:180 Ω
Resolution:12 bits
Absolute error:0.15% of full scale (20 mA)
Diagnostic:Force-to-value diagnostic (FVD)
Digital Input Module
Points:32, commoned
Nominal input voltage:24 V DC
Operational voltage range:15–30 V DC
Absolute maximum input voltage:33 V DC
Absolute maximum reverse input voltage:–0.6 V DC
Input delay:<10 ms, On to Off or Off to On
ADC scan time:<1 ms for all 32 points
Analog Output Module
Type:TMR
Resolution:12 bits
Diagnostic:Forced-switch diagnostic (FSD)
Points:4, commoned-return
Output current range:4–20 mA output, controlled
External loop power:32 V DC, maximum24 V DC, nominal
Digital Output Module
Points:16, commoned
Nominal output voltage:24 VDC
Specified operational voltage range:15 to 30 VDC
Absolute maximum output voltage:33 VDC
Absolute maximum reverse input voltage:– 0.6 VDC
Leakage to load (Off state):<1 mA
Diagnostic glitch duration <2 ms, maximum:500 Ps, typical
On state voltage drop:<1.0 VDC @ 1.5 A
Interconnection Cable
Length:10 meters
Shielding:Dual/triple shielding
Wire Gauge:22-24 AWG
Voltage Rating:300V AC/DC
Fieldbus Communication Interface
CI810B AF100 Fieldbus Communication Interface
2*AF100 Twisted Pair Modems.
Including:
1 pce Power Supply Connector 3BSC840098R1
1 pce TB807 Modulebus Terminator 3BSE008538R1
2 pcs Terminal Blocks 3BSC840098R1
Embedded CPU Board
Motorola PowerPC
SDRAM: 128 MB–1 GB
Non-Volatile Storage: 4–32 MB Flash
1–2 x 10/100BASE-T Ethernet
2–4 x RS-232/422/485
CRT/VGA output
Single-board
Processor Module Assembly
10/100 Ethernet (RJ-45)
2–4 x RS-232/422/485
Support for MIL-STD-1553
Clock Speed: 500 MHz–1.2 GHz
VMEbus Interface: VME64x
Interconnection Cable
Direct connection between two
FS-CP series process controllers
10 meters long
Shielded twisted pair design
Easy to install and use
Hot-pluggable
CPU RAM backup battery
AUXILARY BATTERY MODULE
15.0 AMP-HOURS
COMPATIBLE WITH ALL BATTERY
CONNECTORS ON IC693 POWER SUPPLIES
MEMORY BACKUP BATTERY
Remote I/O Controller Module
I/O Channels: 4–20 mA
Scalability: 8–16 I/O points per module
Data Transfer Speed: Up to 100 Mbps
Voltage: 18–32 VDC
Current Draw: <2 A typical
Operating Temperature: –40°C to +70°C
Storage Temperature: –50°C to +85°C
Humidity: 5–95% RH (non-condensing)
Industrial Motherboard
Slots: 1–2 x SODIMM slots
Capacity: Up to 16–32 GB
Chipset: Intel H110/Q170 or AMD
Network:2–4 x Gigabit Ethernet
Power Input:12–24 V DC
Wide operating temperature:(-40°C to +85°C with proper airflow)
Humidity tolerance: 5–95% (non-condensing)
Ethernet network interface unit
RX3I NIU WITH TWO SERIAL PORTS
20K OF LOCAL LOGIC
MODULE REQUIRES UNIVERSAL BASE (IC695CHSXXX)
REQUIRES ETHERNET MODULE (IC695ETM001)
NIU SUPPORTS ALL RX3I I/O MODULES
Communication Module
Communication Protocol:Modbus TCP/IP, DeviceNet
Data Rate:Up to 1 Mbps
Power Consumption:L ess than 4W
Operating Temperature:-40C to +70°C
Mounting Type:Panel Mount
SMC Flex Interface Board
INTERFACE BOARD
SMC FLEX INTERFACE PCB BOARD
FOR SOFTSTART
Input Voltage:24V DC
Communication Ports:RS-485, EtherNet/IP
Current/Power Ratings:5A at 240V AC
Analog I/O: Standard 0-10V
Processor module
AC500-eCo Processor module
Memory 4MB
12 DI 24 VDC. 6 DO-Relay
2 DC 24 VDC
Ethernet interface
3 option slots
LV AC industrial single drive module
ACS880-04 drives
3AXD10000497831
LV AC industrial single drive module
IEC: Pn 500 kW, 715 A, 500 V
UL: Pld 600 Hp, 705 A, 460 V
Number of Phases:3-phase
Enclosure Type NEMA:Open Type
Operating Humidity (RHamb):5 ... 95
Sound dB (A):72 dB(A
Frequency (f): 47.5 ... 63 Hz
Frame Size: R11
Input Voltage (Uin):380 ... 500 V

Copyright Notice © 2004-2024 amikong.com All rights reserved
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.