General Purpose Equipment Monitor
Vibration Variables ±1% of full-scale range
SpeedVariables:± 0.5 RPM + 0.015% ofreading
Speed Up to 4 speed measurements
Speed 100 - 100,000 rpm
Direct 100 to 500 μm (3 to 20 mils) peak-topeak
PCBA CIRCUIT BOARD
Voltage: 24V DC or 48V DC
Power Consumption: 10–50W
Protection: Overvoltage/overcurrent protection
Semiconductor Circuit Board
Power Requirements: 24V DC
Signaling Interfaces: Communication protocols
Operating Temperature: 0–50°C
Protection Rating: IP20
VELOMITER TERMINAL CARD CIRCUIT BOARD ASSEMBLY
Series: Velomitor Terminal Card
Operating Temperature: Typically -20°C to +65°C
Humidity: Up to 95% non-condensing
Dual Velocity Monitor
Channel Input Option(01): Dual Velocity Inputs,
Channels A & B indicate in peak velocity
Transducer Type Option(04): Velomitor 100 mV/in/s
Channel A Full-scale Range Option(02): 0 - 1 in/s pk
Channel B Full-scale Range Option(02): 0 - 1 in/s pk
Agency Approval Option(01): CSA/NRTL/C
Intrinsic Safety Barrier Option(00): None
Alarm Relay Option(06): Hermetically-Sealed (Velomitor)
Trip Multiply Option(00): None
Control Board
Operating Voltage: Typically 24 V DC
Input Voltage: 380-460 VAC
Output Voltage: 0-460 VAC
Output Frequency: 0-60 Hz
Output Power: 1.5 kW
Efficiency: Up to 98%
3300 NSv Proximity Probes
3300 NSv Probe
1/4-28 UNF thread, withoutarmor
1 0 1.0 metre (39 in)
0 2 Miniature coaxial ClickLocconnector
standard cable
0 5 Multiple Approvals
3300 NSv Proximity Probes
3300 NSv Probe
1/4-28 UNF thread, withoutarmor
1 0 1.0 metre (39 in)
0 2 Miniature coaxial ClickLocconnector
standard cable
0 5 Multiple Approvals
Digital Output Module
Output Channels:32
Output Type:SINK (Open Drain)
Load Voltage:15 30 VDC Maximum
Load Current:0.1 A per channel (Max)
On-State Voltage:0v VDC
Off-State Voltage:24 V (typ)
Off-State Leak Curren:100 µA (max)
Turn-On/Turn-Off Time:10 ms (max)
Revision C IO Link Cable
Type: IO Link Cable
Part Number: 51202341-102 Revision C
Country of Origin: USA
Cable Length: 1 meter
Shielding: Shielded
HORIZONTAL BACK PLANE PWA
Operating Voltage: 24 V DC
Input Current: 1 A
Output Power: 20 W
Bus Interface: RS-485
Operating Temperature: -20°C to +70°C
Humidity Range: 5% to 95% non-condensing
Certifications: CE, UL, ISO 9001
IOL FOE PM VIOLET - 0.5M
Cable Type: Fiber Optic Ethernet.
Connector Type: IOL (Input/Output Link) connectors.
Length: 0.5 meters
Operating Voltage: 24 VDC.
Operating Current: 0.5 A.
Maximum Power Consumption: 12 W
Trusted CCoat 4 Way Expander Intfc
Voltage Range: 18 Vdc to 32 Vdc
Power Consumption: Maximum 1.7 W
Transmitter Power: Minimum -15 dBm
Receiver Sensitivity: -28 dBm
Maximum Propagation Time Difference: 80 ns
Maximum Fiber Length Difference: 15 m
Operating Temperature: 0°C to 60°C (32°F to 140°F)
Non-Operating Temperature: -25°C to 70°C (-13°F to 158°F)
Relative Humidity: 10% to 95% non-condensing
Trusted CCoat Fiber Tx Rx Unit
Voltage Range: 18 Vdc to 32 Vdc
Power Consumption: Maximum 1.7 W
Transmitter Power: Minimum -15 dBm
Receiver Sensitivity: -28 dBm
Maximum Propagation Time Difference: 80 ns
Maximum Fiber Length Difference: 15 m
Trusted 24V DC Roof Mounted Fan Tray
Simple installation and connection
Capable of moving 69 m3/h (40.6 ft3/min)
24 Vdc operation
Low noise (32 db per fan)
Meets IP20 with roof cowl fitted
Trusted CCoat Expan Proc Module
Supply Ratings:20 - 32 Vdc, 45 W
Backplane (IMB) Supply:20 Vdc to 32 Vdc
Power Dissipation:45 W Backplane Supply
Module Location:T8300 Expander Processor Slot
Fusing Not User Serviceable
Operating Temperature :0 °C to +60 °C (+32 °F to +140 °F)
Storage Temperature: -25 °C to +70 °C (-13 °F to +158 °F)
Relative Humidity :10 % – 95 %, non-condensing
Trusted Power Distribution Unit
Visual indications of input power supply status.
Visual indication of individual fuse status.
Common alarm of fuse status via volt-free contact.
Link selectable supply voltage options
Trusted Power Distribution Unit
Voltage Range 22 Vdc to 28 Vdc
Input Current 60 A max
Conductor Clamping Range (LU10.16) 0.5 mm2 to 16 mm2
Max Switching Voltage 60 Vdc or 125 Vac
Operating Temperature 0 °C to +60 °C (+32 °F to +140 °F)
Non-operating Temperature -25 °C to +70 °C (-13 °F to +158 °F)
Trusted Output Power Distribution Unit
Supports up to three Trusted Sourcing Output Modules.
Dual stud power connection for either single or dual feed.
0 V module reference via BLZ 2-part connectors.
Power Shelf
POWER SHELF 4U MOUNTING KIT POWER PORT MAINS PLUGS
19 inch x 1U chassis
for up to 3 Power Packs.
Includes 4U fixing kit,
Power Port (with push fit BLZF3.5/10 connector),
mains plugs and retaining clips
Trusted TMR I/O SmartSlot Slot Cables
Cable Type: Multi-core shielded cable
Length: 2 meters
Voltage Rating: Typically rated for 300 V AC/DC
Current Capacity:4–20 mA analog
Operating Temperature: -40°C to +85°C
Trusted TMR I/O SmartSlot Slot Cable
Cable Type: Multi-core shielded cable
Length: 2 meters
Voltage Rating: Typically rated for 300 V AC/DC
Current Capacity:4–20 mA analog
Operating Temperature: -40°C to +85°C
Communications Cable
Communications Cable Assembly
From Communication Interface (T8151) to flying leads
Impedance: 100–120 Ω (for twisted-pair cables).
Voltage Rating: 300 V AC/DC (typical).
Data Rate: Up to 1 Gbps
Operating Temperature: -40°C to +85°C
EXPANDED MODULE TRUSTED FIBRE TX RX UNIT
Voltage: 100–240V AC (auto-ranging), 50/60 Hz.
Current: 10A (max at 100V AC)
Efficiency: ≥90%
Operating Temperature: -20°C to +70°C
Humidity: 5–95% non-condensing
Copyright Notice © 2004-2024 amikong.com All rights reserved
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.