Inverter Power Unit
Perfect Harmony Medium voltage drive
PERFECT HARMONY power cell G4 Cell 200A, 750 V.
Current: 200 A
Voltage (DC Link): 750 V DC
Power: 150 kW
Frequency: Up to 3 kHz
Dead-Time Compensation: <1 μs IGBT offset
Auxiliary Power Input:24 V DC
Robicon G4 Power CELL
Robicon G4 Power CELL, 140A, 750V
Perfect Harmony Medium voltage drive
LDZ10500424.140
Voltage (DC Link): 750 V DC ±10%
Rated Current (Continuous): 140 A
Power Rating: 105 kW
Operating Temp.: Max cell temperature ≤85°C
Capacitors: 12,000 µF ±20% 900 V DC
CPU BOARD
CPU BOARD ELECTRONIC MODULE
FOR CONVERTER
RAM ≤ 256 MB
Flash ≤ 512 MB
Digital I/O:24 VDC, ±10%
Analog Inputs: 0–10 V/4–20 mA
Input Voltage: 24 VDC ±10%
Isolation: Reinforced (3000 VAC)
Max Power Draw: 20–50 W
REPLACEMENT IPD CARD
SINAMICS S120
Replacement IPD card
for air-cooled Basic Line Module
710kW 380-480V 3AC/1500A
FREQUENCY DRIVE POWER BOARD
Range: 320–1244 VDC
Current: 0.2–0.7 A
DC Input: 24 VDC
Output Power: 180 W
Efficiency: Likely ≥85%
Operating Ambient: 0°C to +50°C
Isolation: Input-to-output ≥2500–3000 VAC
Voltage Matching: 24 VDC
GEN5 VFD Power Cell
GEN5 VFD Power Cell
GH180 Medium Voltage Drives
Voltage Class:3.3 kV
DC Link Voltage: Standard 750 V DC
L-L Nominal:3.3 kV–6.9 kV
Continuous Output Current: 240–300 A
Pressure Transmitter
SITRANS P320 Pressure transmitter
7Mf0300-1Qf01-5Sf2-z
Pressure Range: Adjustable span
Accuracy: ±0.075% to ±0.25%
Response Time: ≤30 ms
Output Signal: 4–20 mA HART
Supply Voltage: 10.5–45 V DC
CPU Module
Processor Type: 32-bit or 64-bit RISC-based
Program Memory: 512 KB–8 MB
Data Memory: 64 KB–2 MB
Execution Speed: ~0.1–0.3 μs
Analog I/O:4–20 mA or ±10 V inputs
Voltage Rating: 24 VDC (±15%)
Power Consumption: 10–30 W
Operating Temperature: 0°C to 55°C (32°F to 131°F)
Storage Temperature: -25°C to 75°C (-13°F to 167°F)
3300 NSv Proximity Probes
330901 3300 NSv Probe
1/4-28 UNF thread,without armor
Minimum unthreaded length: 0.4 in
Minimum case length: 3.5 in
50 5.0 meters (16.4 feet)
01Miniature coaxial ClickLoc connector
with connector protector, standardcable
00 Not required
3300 XL 11 mm Proximity Probes
330703 3300 XL 11 mm Probe
M14 x 1.5 thread,without armor
Minimum unthreaded length:0 mm
Minimum length:40 mm
10 1.0 meter (3.3 feet)
01Miniature coaxial ClickLocconnector
with connectorprotector, standard cable
05 Multiple Approvals
3300 XL 8 mm Proximity Probes
330102 3300 XL 8 mm Probe
3/8-24 UNFthread, with armor
Minimum unthreaded length: 0.0 in
Minimum case length: 3.0 in
10 1.0 meter (3.3 feet)
02 Miniature coaxial ClickLocconnector
standard cable
00 Not required
3300 XL 8 mm Proximity Probes
330101 3300 XL 8 mm Probe
3/8-24 UNFthread, without armor
Minimum unthreaded length: 0.0 in
Minimum case length: 3.5 in
10 1.0 meter (3.3 feet)
02 Miniature coaxial ClickLocconnector
standard cable
00 Not required
Interconnect Cable
3-conductor shielded
22 AWG(0.5 mm2) cable
with 3-socketplug at one end
terminal lugs atthe other end
Minimum lengthof 2.0 ft (0.6 m)
maximumlength of 99 ft (30 m)
Velomitor CT Velocity Transducer
08 Plate Stud 3/8-in 24 to 1/2-in 20
00 MIL-C-5015 connection interface
00 No Approvals
Velomitor CT Velocity Transducer
Standard Interconnect Cable
3-conductor shielded
22 AWG (0.5 mm2) cable
with 3-socketplug at one end
terminal lugs at the other end
Minimum lengthof 2.0 ft (0.6 m)
maximum length of 99 ft (30 m)
3300 XL Standard Extension Cable
045 4.5 meters (14.8 feet)
11 Armored FluidLoc cable
05 CSA, ATEX, IECEx Approvals
3300 XL 8 mm Proximity Probes
330102 3300 XL 8 mm Probe
3/8-24 UNFthread, with armor
Minimum unthreaded length: 0.0 in
Minimum case length: 1.2 in
05 0.5 meter (1.6 feet)
02 Miniature coaxial ClickLocconnector
standard cable
05 CSA, ATEX, IECEx Approvals
Perfect Harmony Medium voltage drive
Voltage Class: Medium Voltage
Series: Perfect Harmony GH/VFD 180
Power Range: Up to 50–100 MW
Input Voltage 50/60 Hz, 3-phase
Output Voltage:0–60 Hz variable
Output Current (max):150–3500 A
Control panel
SINAMICS PERFECT HARMONY GH180 Drives CCB
Communication Interfaces:Fiber-optic loops
Input/Output:24-bit I/O
Power Supply:24 V DC (±20%)
Ambient Temp.:0°C – +50°C
Power unit fuses
DC link/integrated power module
Input rectifiers
Output IGBTs in drives
Voltage Rating:690–1000 VDC
Current Rating (Cont.):450–700 A
Interrupting Capacity:≥100–150 kA
CELL WITH SUBMODULE
Series: Innomotics G5 Drive
Function: Power Submodule for MV Drive Systems
Current Rating (Cont.):45 A
Voltage Rating:750 V DC
Overload Capacity:Up to 150% current for 60 s
Switching Frequency:Optimized ≤20 kHz
Topology:IGBT Half-Bridge Module
Air Filter Assembly
Airflow Capacity:≥15–40 m³/h
Filter Class:G4/F9 grade
Temp. Rating:−20°C to +70°C.
Pressure Drop:10–20 Pa
Material Standards UL94-V0
Housing Material:Galvanized steel or high-density plastic
Robicon MV Drive
Input Voltage:3-phase AC 6.6 kV
Output Frequency Range:0.0–120 Hz
Rated Power:5–40 MW
Output Voltage (Motor):3 kV to 6.6 kV
Overload Capacity:120% of rated current
Efficiency:>97%
Operating Temperature:0°C to +40°C
Ambient Humidity:Up to 95% non-condensing
DC Power Supply
Series: NXGPRO Plus NCP
Input Voltage:90 – 290 V AC ³ph
Output Voltage (DC):±24 V/48 V DC
Rated Current Per:Cell ≥200 A
Power Rating:6 kW per cell
Efficiency:≥95%
Resilient Networks: -48 V/24 V
POWER SUPPLY I/O BOARD
GH180 NXGpro USER I/O board
Voltage Input:24 V DC (±10%)
Mounting: Secured within GM150 Cabinet
Operating Temperature: 0°C – 55°C
RUN/STOP: Operational mode of the board

Copyright Notice © 2004-2024 amikong.com All rights reserved
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.