3300 NSv Proximity Probes
330905 3300 NSv Probe
M10X1 thread,without armor
Minimum unthreaded length:80 mm
Minimum length: 130 mm
10 1.0 meter (39 in)
12 Miniature coaxial ClickLoc connector
FluidLoc cable
05 Multiple Approvals
3300 NSv Proximity Probes
330905 3300 NSv Probe
M10X1 thread,without armor
Minimum unthreaded length:00 mm
Minimum length: 100 mm
10 1.0 meter (39 in)
02 Miniature coaxial ClickLoc connector
standard cable
INTERFACE MODULE
Supply Voltage:24V DC (±10%)
Power Consumption:≤4W
Analog Inputs:4x (0-10V / 4-20mA, 12-bit resolution)
Digital Inputs:8x (24V DC, opto-isolated)
Relay Outputs:2x (Form C, 5A @ 250V AC)
Isolation Voltage:2500V AC
Power Board
Input Voltage:3-phase 380-500V AC (±10%), 45-65Hz
Output 1 (+24V DC):10A (240W)
Output 2 (+15V DC):5A (75W)
Output 3 (-15V DC):2A (30W)
Efficiency:≥94% (at full load)
Overvoltage Protection:+32V DC
Analog Signals:0-10V load sharing output
Remote Control:24V DC input
Power supply board
Wide Input Range: 24-250V D
Dual Isolated Outputs: +24V DC
Input Voltage:24-250V DC or 100-240V AC
Output 1 (+24V DC):2A (48W)
Output 2 (±15V DC):±0.5A (15W total)
Ripple Noise:<1% of rated output
Hold-up Time:≥20ms (at full load)
PCB board
Dual-Core Processing – 800MHz PowerPC
Supply Voltage:24V DC ±10%
Power Consumption:18W
Analog Inputs:16x (16-bit, ±10V/4-20mA)
Digital I/O:32x (24V DC, opto-isolated)
Isolation :2500V AC
PROFIBUS DP-V1 (12Mbps)
EtherCAT (100Mbps)
TB30 Terminal Board
SINAMICS / SIMOTION
TERMINAL BOARD
TB30 FOR
CONTROL UNIT CU320-X
SIMOTION D4X5-X
POWER SUPPLY BOARD
Dual Output: +24V DC (5A)
Active PFC: >0.95 power factor
Input Voltage:85-264V AC
Output 1 (+24V DC):5A (120W)
Output 2 (+5V DC):2A (10W)
Efficiency:≥92% (at full load)
Ripple Noise:<1% of rated output
3300 XL 11 mm Proximity Probes
330701 3300 XL 11 mm Probe
1/2-20 UNFthread, without armor
Minimum unthreaded length:0.0 in
Minimum case length: 2.0 in
02 Miniature coaxial ClickLocconnector
standard cable
00 Not required
Slimline expansion unit
Supply Voltage:24V DC (±15%)
Power Consumption:2W (base unit)
Backplane Current:800mA max
Isolation :1500V AC
Modules per Unit: Up to 8 I/O modules
Digital I/O :16/32 channel
Analog I/O:8/16 channel
Communication:PROFIBUS, Ethernet
Prog.Logic Controller
Memory Size:142 kB
Memory Type User Data:RAM
Controller Processing Time:0.00008 ms
Number of Digital Inputs:8
Number of Digital Outputs:6
Number of Digital Configurable I/Os:0
Input Voltage Type:DC
Rated Voltage (Ur):230 V AC
Supply Voltage:100 … 240 V AC
Prog.Logic Controller
Memory Size:142 kB
Memory Type User Data:RAM
Controller Processing Time:0.00008 ms
Number of Digital Inputs:8
Number of Digital Outputs:6
Number of Digital Configurable I/Os:0
Input Voltage Type:DC
Rated Voltage (Ur):24 V DC
Supply Voltage:20.4 … 28.8 V DC
3300 5mm Proximity Probes
330172 3300 5mm Probe
1/4-28 UNFthread, with armor
0 0 = 0.0 in.
Minimum unthreaded length: 0 8 = 0.8 in
1 0 1.0 metre (3.3 feet)
0 2Miniature coaxial ClickLocconnector
standard cable
0 5 Multiple Approvals
Voltage:230V AC (±10%), 50/60Hz
Power Consumption:28W (max)
Airflow:140m³/h @ 0Pa
Static Pressure:320Pa (max)
Speed:2800 RPM (±10%)
Connector:4-pin Mate-N-Lok
3300 XL 8 mm Extended TemperatureRange (ETR) Proximity Probes
330193 3300 XL 8 mm Probe
M10 x 1 thread,without armor
Minimum unthreaded length: 90 mm
Minimum case length: 20 mm
10 1.0 meter (3.3 feet)
00 Not required
Copyright Notice © 2004-2024 amikong.com All rights reserved
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.