
Kindly Reminder
Can't Find Your Required Components?
If your specific control system parts are not listed on our website, contact us immediately.
Our procurement specialists will source genuine new components tailored to your technical requirements.
All Amikon-supplied automation parts include:
12 Months Warranty
24h /7 online Service ( info@amikon.cn | +86 18020776786 )
Original new Factory Sealed
Kindly Reminder
Can't Find Your Required Components?
If your specific control system parts are not listed on our website, contact us immediately.
Our procurement specialists will source genuine new components tailored to your technical requirements.
All Amikon-supplied automation parts include:
12 Months Warranty
24h /7 online Service ( info@amikon.cn | +86 18020776786 )
Original new Factory Sealed
ANLOG TERM CABLE FLAME
Signal termination for 4–20 mA
Current: 4–20 mA
Voltage: 0–10 V DC, ±5 V DC
Temperature: RTD (Pt100/1000)
Cable Length: 10 meters (indicated by "-10" suffix)
Bend Radius: ≥8x cable diameter
ANALOG INPT TERM CABLE
Current: 4–20 mA
Voltage: 0–10 V DC, ±10 V DC
Gauge: 18–22 AWG
Cable Length: 30 meters
Bend Radius: ≥10x cable diameter
Analog Input Termination Unit
Number of Channels: 8 or 16
Current: 4–20 mA
Voltage: 0–10 V DC, ±10 V DC
Channel-to-channel: ≥250 V AC
Field-to-system: 1500 V AC
Supply Voltage: 24 V DC (±10%)
Power Consumption: ≤5 W
TERMINATION UNIT CABLE
Gauge: 18–24 AWG
Voltage Rating: ≤60 V DC
TERMINATION UNIT CABLE
infi-90 Termination Loop Cable
SOE Time Keeper Master
Analog inputs: 0–10 V, 4–20 mA
Analog outputs: 0–10 V, 4–20 mA
Power Supply:24 V DC (±10%)
Supply Voltage:24V DC (19.2–28.8V) via backplane
Power Consumption:1.8W (typical), 2.5W (max)
Isolation 1500V AC (channel-to-logic)
Digital Input Module
DIGITAL INPUT MODULE
SYMPHONY PLUS
INFI 90
DI Module. 16 CH
Universal, 32 Jumpers
MODEM CABLE 9PIN MALE-MALE
MODEM CABLE 9PIN MALE-MALE
Codex 2111 Modem to CSKb
CRT - 8' (OIS & MCS) serial cable
MCS Power Supply
Input Voltage Range:24 V DC
Input Connection:2-pin removable terminal block
Input Current :3.0 A max @ 24V DC
Output Voltage:5.1 V DC
Output Current:4.0 A max
Power Rating:20 W
Console Distribution Panel
Expandable /0 Options
RS-232 & RS-485 Communication Options
Easy to Install
Rugged, NEMA 4 Packaging
Micro-DCI Panel Controller Assembly
High-Power, Extra-Compact Controller
8 Standard Control Templates
Flexible Control Logic
Easy setup = front panel or industry's
easiest configuration software
Easy-TuneTM PID self-tuning algorithm
Expandable /0 Options
RS-232 & RS-485 Communication Options
Easy to Install
Rugged, NEMA 4 Packaging
TERMINATION CABLE 8FT
TERMINATION UNIT CABLE
I/O Modules Termination
I/O Module to Termination Unit Cable
TERMINATION CABLE 18FT
TERMINATION UNIT CABLE
I/O Modules Termination
Infi 90 Termination Cable Assy
I/O Module to Termination Unit Cabl
CABLE TERMINATION LOOP 19FEET
TRMNTN UNIT CABLE
19FT
I/O Module to TU Cable
I/O Module to Termination Unit Cable
FLAME DETECTOR
Type:Self-Checking Ultraviolet
Supply Voltage:20 - 30 V DC
Power Consumption:Typically < 3 W
Contact Rating:Typically 5 A @ 230V AC
Cable Entry:Conduit entry
CABLE COMMUNICATION - 100 FEET
NKCL01-100
Coax INFI-Net Comm Link - 100 Ft (Pvc)
Connect NTCL to NTCL, Must use with NKTL01
15240 mm
PLANT COMMUNICATION CBLE
NKCL01-50
Coax INFI-Net Comm Link - 50 Ft (Pvc)
Connect NTCL to NTCL, Must use with NKTL01
15240 mm
Control Processor Module
Harmony-07
Control Processor Module
High-performance processing unit for real-time control and data processing
Supports industrial communication protocols such as Modbus, Profibus, Ethernet/IP
24V DC
-20°C to +60°C
Terminal Module
Select I/O
Terminal Module
Module Termination Unit for Select I/O IS
Two slots for connection of Generic I/O modules
Digital Output Module
NTRO05-A
Digital Output Module
5 channels
Relay output or transistor output
4 V DC or 120 V AC output, depending on configuration
Maximum output current per channel: 1 A
24 V DC power supply
Termination Loop Cable
NKSD01-15
Termination Loop Cable
Shielded twisted pair or other cable
types suitable for industrial applications
15 meters
Copyright Notice © 2004-2024 amikong.com All rights reserved
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.