
SMART DIGITAL OUTPUT MODULE
SMART DIGITAL OUTPUT MODULE
SIMATIC S7-200
8 DIGITAL OUTPUTS
2 AMP RELAY
Inverter Drive
SINAMICS V20
380-480 V 3AC -15%/+10% 47-6
Rated power 0.75 kW with 150% overload for 60 sec
unfiltered I/O interface: 4 DI, 2 DQ, 2 AI, 1 AO
Fieldbus: USS/Modbus
RTU with built-in BOP Degree of protectionIP20/UL
open Size: Size A 90x150x146
PULSE TRANFORMER
Isolation Voltage: Typically 2–4 kV
Primary/Secondary Voltage: 5–24 V AC/DC input
Operating Temperature: -40°C to +85°C
Certifications: Complies with IEC/EN
Turns Ratio: 1:1 or custom ratios
Impedance:50–100 Ω
Single Board Computer
Network: Dual Gigabit Ethernet ports.
USB: USB 2.0/3.0 ports for peripheral connectivity.
Serial: RS-232/422/485 interfaces.
Graphics: VGA, DVI, or DisplayPort for display output
Operating Temperature: -40°C to +85°C (ruggedized variants).
Certifications: MIL-STD-810 (shock/vibration), CE, RoHS.
Power Input: 5V or 12V DC
3300 XL 8 mm Proximity Probes
3300 XL 8 mm Probe
3/8-24 UNFthread, without armor
3300 XL 8 mm Proximity Probes
12 Miniature coaxial ClickLocconnector
FluidLoc cable
05 CSA, ATEX, IECEx Approvals
3300 XL 8 mm Proximity Probes
3300 XL 8 mm Probe
3/8-24 UNFthread, without armor
3300 XL 8 mm Proximity Probes
12 Miniature coaxial ClickLocconnector
FluidLoc cable
05 CSA, ATEX, IECEx Approvals
3300 XL 8 mm Proximity Probes
3300 XL 8 mm Probe
3/8-24 UNFthread, without armor
3300 XL 8 mm Proximity Probes
12 Miniature coaxial ClickLocconnector
FluidLoc cable
05 CSA, ATEX, IECEx Approvals
Binary output module
24 binary outputs with enclosed relays (NO contacts)
Current carrying capacity of the relays: max. 1 A
Channel-by-channel isolation of the outputs
Module is capable of redundant operation
Monitoring of the module
Counter for switching cycles (channel by channel)
Analog output module
16 analog outputs, output signal 0/4 ... 20 mA,
channel-by-channel configuration
Load: max. 700 Ohm
Monitoring of loads
Channel-by-channel isolation of outputs
Module is capable of redundant operation
Digital communication with field devices according to
HART protocol (Version 5.0 / 5.1)
Monitoring of modules
Binary input module
32 binary inputs divided into two groups each with 16 inputs
Process current circuits in accordance
with EN 50020 with type of protection EEx ib IIC
Combined installation possible with
"Non-Ex-modules" in one module sub-rack
Signal recording with 1 ms time resolution
Monitoring of module
Central galvanic separation of system inputs
Group-set filter time
Module is capable of redundancy
Binary input module
32 binary inputs divided into two groups each with 16 inputs
Process current circuits in accordance
with EN 50020 with type of protection EEx ib IIC
Combined installation possible with
"Non-Ex-modules" in one module sub-rack
Signal recording with 1 ms time resolution
Monitoring of module
Central galvanic separation of system inputs
Group-set filter time
Module is capable of redundancy
Coupling Unit
Data Rate: Up to 12 Mbps
Isolation:1500 V AC
Power Supply: 24 V DC (±10%)
Power Consumption: Typically 5–10 W
Fieldbus Port: 9-pin D-sub or M12 for PROFIBUS
Operating Temperature:
-25°C to +70°C (-13°F to +158°F)
Humidity: 5–95% noncondensing
ControlLogix Jumper Bars
BAR JUMPER
CONTROLLOGIX
FOR 36 PIN TERMINAL WIRING BLOCKS
25 PER PACKAGE
Digital Isolated Input Module
Series:ControlLogix
Inputs:16 Individually Isolated; SOE
Input Voltage:125 Volts DC Sink-Source
Operating Voltage Range:90-140 Volts DC
Maximum Input Current, Off-State:0.3 milliamps
Power Dissipation (Max):5.5 Watts at 60 degrees Celsius
Module Type:Digital Isolated Input Module Series of Events
Diagnostic Input Module
Series:ControlLogix
Module Type:Diagnostic Input Module
Inputs:8 Diagnostic
Input Voltage:120 Volts AC
Operating Voltage Range:79-132 Volts AC
Input Delay Time:Programmable 9 or 18 milliseconds
Minimum Operating Current:5 milliamperes at 79 Volts AC
Maximum Operating Current:16 milliamperes at 132 Volts AC
Maximum Input Current, Off-State 2.5 milliamperes
Variable speed drive
Range of product:Easy Altivar 610
Product or component type:Variable speed drive
Device short name:ATV610
Variant:Standard version
type of cooling:Forced convection
Supply frequency:50...60 Hz +/-5 %
Network number of phases:3 phases
rated supply voltage:380...460 V - 15...10 %
PowerFlex 753 AC Drive
Bulletin Number:PowerFlex 753 AC Drive
with Embedded I/O
Corrosive Gas Protection and Cooling Type:
Standard Protection, Forced Air
Voltage Class:400 VAC, 3 PH
Output Current:456 Amps, 250kW ND, 200kW HD
Enclosure Type:Open Type
Input Type:AC Input with Precharge, no DC Terminals
Frame Size:Frame 7
EMC Filtering Options:Filtered
CM jumper installed (preferred)
Dynamic Braking:DB Transistor
PowerFlex 753 AC Drive
Bulletin Number:PowerFlex 753 AC Drive
with Embedded I/O
Corrosive Gas Protection and Cooling Type:
Standard Protection, Forced Air
Voltage Class:400 VAC, 3 PH
Output Current:456 Amps, 250kW ND, 200kW HD
Enclosure Type:Open Type
Input Type:AC Input with Precharge, no DC Terminals
Frame Size:Frame 7
EMC Filtering Options:Filtered
CM jumper installed (preferred)
Dynamic Braking:DB Transistor
PowerFlex 753 AC Drive
Bulletin Number:PowerFlex 753 AC Drive
with Embedded I/O
Corrosive Gas Protection and Cooling Type:
Standard Protection, Forced Air
Voltage Class:400 VAC, 3 PH
Output Current:456 Amps, 250kW ND, 200kW HD
Enclosure Type:Open Type
Input Type:AC Input with Precharge, no DC Terminals
Frame Size:Frame 7
EMC Filtering Options:Filtered
CM jumper installed (preferred)
Dynamic Braking:DB Transistor
PowerFlex 753 AC Drive
Bulletin Number:PowerFlex 753 AC Drive
with Embedded I/O
Corrosive Gas Protection and Cooling Type:
Standard Protection, Forced Air
Voltage Class:400 VAC, 3 PH
Output Current:367 Amps, 200kW ND, 160kW HD
Enclosure Type:Open Type
Input Type:AC Input with Precharge, no DC Terminals
Frame Size:Frame 7
EMC Filtering Options:Filtered
CM jumper installed (preferred)
Dynamic Braking:None
PowerFlex 753 AC Drive
Bulletin Number:PowerFlex 753 AC Drive
with Embedded I/O
Corrosive Gas Protection and Cooling Type:
Standard Protection, Forced Air
Voltage Class:400 VAC, 3 PH
Output Current:302 Amps, 160kW ND, 132kW HD
Enclosure Type:Open Type
Input Type:AC Input with Precharge, no DC Terminals
Frame Size:Frame 7
EMC Filtering Options:Filtered,
CM jumper installed (preferred)
Dynamic Braking:None
PowerFlex 753 AC Drive
Bulletin Number:PowerFlex 753 AC Drive
with Embedded I/O
Corrosive Gas Protection and Cooling Type:
Standard Protection, Forced Air
Voltage Class:400 VAC, 3 PH
Output Current:302 Amps, 160kW ND, 132kW HD
Enclosure Type:Open Type
Input Type:AC Input with Precharge, no DC Terminals
Frame Size:Frame 7
EMC Filtering Options:Filtered,
CM jumper installed (preferred)
Dynamic Braking:None
PowerFlex 753 AC Drive
Bulletin Number:PowerFlex 753 AC Drive
with Embedded I/O
Corrosive Gas Protection and Cooling Type:
Standard Protection, Forced Air
Voltage Class:400 VAC, 3 PH
Output Current:302 Amps, 160kW ND, 132kW HD
Enclosure Type:Open Type
Input Type:AC Input with Precharge, no DC Terminals
Frame Size:Frame 7
EMC Filtering Options:Filtered,
CM jumper installed (preferred)
Dynamic Braking:None
Copyright Notice © 2004-2024 amikong.com All rights reserved
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.