Ethernet RIO drop adaptor
Number of port 3
Integrated connection type
Ethernet IP/Modbus TCP service port
ommunication Port Protocol
Ethernet IP/Modbus TCP
Topology
Daisy chain loop
Flex I/O 1794
Flex IO 8-Channel RTD
Thermocouple Input Module
-40…100 mV DC for thermocouples
0…325 mV for RTDs mV default
0.05% of full range in mV mode
Product Type:I/O Power Supply
Input Voltage range:19.2-31.2 VDC
Power consumption:7.5 W @ 60 °C (140 °F)
Current capacity @ 5V DC:2.0 A
Current capacity @ 24V DC:0.8 A
Inrush current, max:30 A @ 31.2V DC
Product Line:CompactLogix
Input Power:24VDC
Shipping Weight:2 pounds
Series:A and B
Solid Wire Size:22 to 14 AWG
Stranded Wire Size:22 to 16 AWG
Product Family: Compact I/O
Product Line CompactLogix
Product Type: Discrete Output Module
Module Type Relay Output Module
Operating Voltage 5 to 265 Volts AC or 5 to 125 Volts DC
No. of outputs: Sixteen (16)
Enclosure Type Open
No. of Groups: 2
No. of Channels per group: 8
Communication Cable 16 Point
Product Line:CompactLogix
Product Type: Discrete Output Module
Module Type:Relay Output Module
Input Type:Relay Output
No. of outputs: Eight (8)
Power Supply Distance rating:8
Operating Voltage range:5 to 265V ac 5 to 125V dc
Signal delay, On:10 ms
Wire Size (Solid):22 to 14 AWG
Wire Size (Stranded):22 to 16 AWG
Bus Current draw, 5.1 V: 125 mA
Wire Type:Copper-90 degrees
Module Type:Analog Input Module
Input Type:Analog Input
No. of Inputs:8 Inputs; Differential or Single Ended Inputs
Communication Cable:8 Point
Power Supply Distance rating:8
Shipping Weight:2 pounds
Input current range: 0-21 mA
Shipping Dimensions:8 x 8 x 5 inches
Current signal normal ranges: 0-20mA; 4-20 mA
Series:A and B
Current signal full range: 0-21 mA; 3.2 - 21 mA.
Distance Rating:8 Modules
Input voltage range:0-10.5VDC
1769ASCII
COMMUNICATIONS MODULE
COMPACT LOGIX
ASCII
2 CHANNEL
RS-232/422/485
2 FULL DUPLEX RS-232
2 HALF DUPLEX RS-422/RS-485
Tariff Code: 8517620050
Country of Origin: United States
Output Voltage range:10-31.2 VDC
Nominal output voltage:24VDC
Module Keying:Electronic
Outputs:16-Point Electronically Fused
Voltage:12-24 Volts DC
Operating Voltage Range:10-30 Volts DC
Maximum Output Current Rating-Point:1 Amp at 60 Celsius
Outputs:16-Point Diagnostic
Voltage:24 Volts DC Source
Operating Voltage Range:19.2-30 Volts DC
Maximum Output Current Rating-Point:2 Amps at
Power Dissipation (Max):3.3 Watts at 60 Celsius
Backplane Current at 5 Volts:250 milliamps
Backplane Current at 24 Volts:140 milliamps
1756L71
PROCESSOR MODULE
CONTROLLOGIX
LOGIX5571
CONTROLLER
2 MB USER MEMORY
0.98 MB I/O MEMORY
USB PORT
CHASSIS MOUNT
Tariff Code: 8537109060
Country of Origin: United States