Kindly Reminder
Can't Find Your Required Components?
If your specific control system parts are not listed on our website, contact us immediately.
Our procurement specialists will source genuine new components tailored to your technical requirements.
All Amikon-supplied automation parts include:
12 Months Warranty
24h /7 online Service ( info@amikon.cn | +86 18020776786 )
Original new Factory Sealed
PlantCruise 1,000 SCADA Points Redundancy Adder
Server Redundancy
SCADA Points
PlantCruise 1,000 SCADA Points
Redundancy Adder
PlantCruise 100 SCADA Points Redundancy Adder
Server Redundancy
SCADA Points
PlantCruise 100 SCADA Points
Redundancy Adder
PlantCruise 50,000 SCADA Points Adder
PlantCruise 50,000 SCADA Points Adder
to Database Size
PlantCruise SCADA Point Adder 50,000 POINT
PlantCruise 25,000 SCADA Points Adder
PlantCruise 25,000 SCADA Points Adder
to Database Size
PlantCruise SCADA Point Adder 25,000 POINT
PlantCruise 10,000 SCADA Points Adder
PlantCruise 10,000 SCADA Points Adder
to Database Size
PlantCruise SCADA Point Adder 10,00 POINT
PlantCruise 8,000 SCADA Points Adder
PlantCruise 8,000 SCADA Points Adder
to Database Size
PlantCruise SCADA Point Adder 8,000 POINT
PlantCruise 5,000 SCADA Points Adder
PlantCruise 5,000 SCADA Points Adder
to Database Size
PlantCruise SCADA Point Adder 5,000 POINT
PlantCruise 2,000 SCADA Points Adder
PlantCruise 2,000 SCADA Points Adder
to Database Size
PlantCruise SCADA Point Adder 2,000 POINT
PlantCruise 1,000 SCADA Points Adder
PlantCruise 1,000 SCADA Points Adder
to Database Size
PlantCruise SCADA Point Adder 1,000 POINT
PlantCruise 100 SCADA Points Adder
PlantCruise 100 SCADA Points Adder
to Database Size
PlantCruise SCADA Point Adder 100 POINT
PlantCruise 2,000 Process Points Redundancy Adder
Database Size Expansions
PlantCruise 2,000 Process Points Redundancy Adder
to Database Size
Software License
PlantCruise DCS System
Requires PlantCruise Base
PlantCruise 1,000 Process Points Redundancy Adder
Database Size Expansions
PlantCruise 1,000 Process Points Redundancy Adder
to Database Size
Software License
PlantCruise DCS System
Requires PlantCruise Base
PlantCruise 100 Process Points Redundancy Adder
Database Size Expansions
PlantCruise 100 Process Points Redundancy Adder
to Database Size
Software License
PlantCruise DCS System
Requires PlantCruise Base (CV-DBASE1)
PlantCruise 2,000 Process Points Adder
PlantCruise 2,000 Process Points Adder
to Database Size
Software License
PlantCruise DCS System
Requires PlantCruise Base (CV-DBASE1)
PlantCruise 1,000 Process Points Adder
PlantCruise 1,000 Process Points Adder
to Database Size
Software License
PlantCruise DCS System
Requires PlantCruise Base (CV-DBASE1)
PlantCruise 100 Process Point Adder
PlantCruise 100 Process Points Adder
to Database Size
Software License
PlantCruise DCS System
Requires PlantCruise Base (CV-DBASE1)
PlantCruise Redundancy Base Software
Redundancy Module for PlantCruise
Requires PlantCruise Base
High-availability DCS
Xeon 4-core 2.4GHz+
16GB (32GB recommended)
500GB SSD
PlantCruise Process points with base
Active Directory/LDAP
PlantCruise (Process Points License)
Up to 50,000
Scan Rate:100ms (configurable)
Alarm Handling:10,000 alarms/sec
Historical Data Storage:1M tags @ 1-sec intervals
Redundancy Switchover:<1 sec
PlantCruise Base Software
SCADA Interfaces
OPC and Data Exchange Options
Version Designation:CV-DBASE1
Type:Process Control System
Architecture:Distributed Client-Server
Deployment:Virtualized/Physical
Real-time Control:100ms scan cycles
I/O Capacity:50,000 points
Alarm Management:10,000 alarms/sec
Historical Storage:1M tags @ 1sec intervals
Redundancy:Hot standby servers
Smart Pressure Transmitter
ST 3000 Smart Pressure Transmitter
Series 900 Differential Pressure
Span : 0-10" to 0-400" H2O/0-25 to 0-1000 mbar
STD924 Body Rating: 3000 psi (210 bar)
E : Wetted process heads
316 St. St, Vent/drain valves and plugs
316 St. St., Barrier diaphragms
316 LSS
Fill Fluid : 1 = Silicone
Touch Panel
Screen Size 15.0 ”
Resolution 1024 x 768
Color 256
Brightnes 250 cd / m
Touch Type Analog
Touch Cell 1024 x 768
CPU 32 bit RISC
Memory 12M Flash Memory
Operating Power AC 85 – 264 V
Power Consumption Max. 25 W
Operating Temperature 0 – 50 °C
Storage Temperature -10 – 60 °C
Enraf Vito LT Interface 762
An electronic converter used
in combination with the VITO probes
HART® communication to tank gauging ATG *2
ATEX KEMA 01ATEX1212
IECEx KEM 05.0014
Kosha certificate; 13-AV4BO-0487
FM I. D. 3015746
CSA certificate 1635480
100-BASE-T CABLE (20M)
Cable Type:Industrial Ethernet (CAT5e)
Length:20 meters (±1%)
Bandwidth:100 MHz
Data Rate:100 Mbps
Impedance:100Ω ±15%
DC Resistance:≤9.38Ω/100m
Capacitance:≤5.6nF/100m
Max Voltage:30V AC
100-BASE-T CABLE (10M)
Category:CAT5e
Length:10.0 meters (±1%)
Bandwidth:100MHz
Data Rate:100Mbps
Characteristic Impedance:100Ω ±15%
Conductor Gauge:24 AWG stranded copper
DC Loop Resistance:≤9.38Ω/100m
Capacitance:≤5.6nF/100m
Max Operating Voltage:30V rms
100-BASE-T CABLE (5M)
100-BASE-T CABLE (5M)
Category:CAT5e
Length:5.0 meters (±0.5%)
Data Rate:100Mbps
Impedance:100Ω ±15%
Conductor Gauge:24 AWG stranded
DC Resistance:≤9.38Ω/100m
Capacitance: ≤5.6nF/100m
Max Voltage:30V AC

Copyright Notice © 2004-2024 amikong.com All rights reserved
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.