In Stock
Fast Shipping Available
Invensys 3511
Ships by Monday, September 7

3511

Pulse Input Module

Shipping Information

  • For inventory products, we support same day shipping upon payment.
  • For urgent needs, we offer same-day shipping on most items for orders placed before 2:00 PM UTC+8 Simply mention your preferred next-day shipping when place the order, and your order will be prioritized to minimize downtime.
  • For indent items, typical turnaround is 1-3 weeks, depending on parts availability and scarcity.
Customs & Documentation
We prepare clear, order-specific documentation for every international shipment, including the commercial invoice, packing list and available product or compliance documents. Before dispatch, our logistics team confirms the consignee details, declared value, shipping terms and destination requirements with you. Tracking information is provided after shipment, helping your team prepare for import clearance with confidence.
Documents checked before dispatch · Shipment details confirmed · Global tracking provided
Payment
Payment is by bank wire only in RMB/CNY, GBP, EUR or USD. Amikon does not accept credit cards or provide credit terms. Cleared payment is required before shipment unless the written quotation expressly states otherwise.
Product Condition
Factory New These are new and current items that are procured directly from the manufacturer.
New In Sealed Package Parts are new. They have not been used and still have their original package seal intact.
New in Original Package These parts are new. The packages were not originally sealed by their original manufacturer.
Quantity
Mobile *
Country/Region *
E-mail *
Company
Content *
(gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Amikong please read our privacy policy.
  • 20+

    years in automation
  • ISO 9001

    certified quality system
  • 12 months

    amikon warranty
  • 2-hour reply

    from your account manager
  • Success Story

    solutions in action
PRODUCT DESCRIPTION

3511 - Pulse Input Module

The Triconex 3511 is an eight-point, non-commoned Pulse Input Module for AC-coupled balanced differential signals from non-amplified magnetic speed sensors.

It measures pulse rates from 20 Hz to 20,000 Hz with a typical 25 ms update rate and is used with rotating equipment such as turbines and compressors.
ACTUAL APPLICATIONS

Where 3511 supports measurement tasks

Manufacturer literature supports the following measurement arrangements. Confirm the complete installed system and the exact ordered configuration before selecting this component.
  • 01 · SPEED INPUTS

    Acquire rotating-equipment speed

    Rotating-equipment speed measurement. Verify the documented field interface, configured limits and approved safety function before service.
  • 02 · OVERSPEED MONITORING

    Evaluate critical speed signals

    Turbine and compressor tachometer input. Verify the documented field interface, configured limits and approved safety function before service.
  • 03 · MAGNETIC SENSORS

    Condition tachometer pulse inputs

    Magnetic speed-sensor signal acquisition. Verify the documented field interface, configured limits and approved safety function before service.

Technical specifications for 3511

  • Product Model
    3511
  • Product Parameters
    Pulse Input Module
  • In stock
    1 unit
  • Manufacturer
    Invensys
  • Input Signals
    8, non-commoned
  • Frequency Range
    20-20,000 Hz
  • Update Rate
    25 ms typical
  • High-Range Accuracy
    +/-0.01% at 1,000-20,000 Hz
  • Load Impedance
    >8 kOhm; 20 kOhm typical
  • Common-Mode Range
    -100 to +100 V peak-to-peak
  • Normal-Mode Range
    1.5-200 V peak-to-peak
  • Over-Range Protection
    +/-150 VDC continuous
  • Slot Keys
    Top 004, bottom 001
  • Logic Power
    <20 W
View all additional

Alternative Names

3511 Tricon Pulse Input Module Magnetic Speed Sensor Input Module
SYSTEM & REPLACEMENT CHECK

Information needed before ordering

Three direct checks to secure your system integration and minimize ordering risks.

Information

System integration Replacement check Manuals & support
SYSTEM CONFIGURATION

Match the installed measurement arrangement

The Triconex 3511 is an eight-point, non-commoned Pulse Input Module for AC-coupled balanced differential signals from non-amplified magnetic speed sensors.
Use 3511 only with the compatible Tricon configuration identified by the complete model number. Match the exact module type and system version. Confirm the chassis, logical slot and mechanical keying. Verify the sensor type, frequency range, shielding and field termination. Check firmware, application configuration and hazardous-area requirements. Do not treat another Tricon family module as interchangeable without controlled Triconex verification.
The 3511 accepts AC-coupled balanced differential pulse inputs. Rapidly changing inputs and sustained channel differences require engineering review because they can cause mis-compare diagnostics.

Features:

  • 8 non-commoned inputs
  • 20-20,000 Hz
  • 25 ms typical update
The 3511 requires exact configuration and installation checks before system integration and commissioning.
INTERCHANGEABILITY

Verify the complete replacement identity before commissioning

Confirm the complete 3511 model number before replacement because related Tricon modules may have different electrical and diagnostic behavior. Record the installed chassis, slot, system version, firmware and termination arrangement. Inspect the connectors, keys, terminals and mounting hardware. Preserve the approved field wiring, scaling, application logic and safety function. Verify current controlled Triconex documentation and hazardous-area requirements. Contact Amikon with 3511 for availability and replacement support.
It measures pulse rates from 20 Hz to 20,000 Hz with a typical 25 ms update rate and is used with rotating equipment such as turbines and compressors.
Retain the validated safety logic, termination arrangement and proof-test records. Recommission every affected channel before the safety function is returned to service.

Features:

  • 8 non-commoned inputs
  • 25 ms typical update
  • +/-0.01% at 1,000-20,000 Hz
The 3511 requires replacement verification of the complete ordered configuration and installed measurement system before commissioning.
DOCUMENTATION STATUS

Browse the Manuals, Datasheets, Official Documents, Links

Important Notice: The Manufacturer's Manual download is a manufacturer technical-data extract, not a complete operation manual. The installation guide contains only source-supported checks. Specifications of other configurations shown on source pages must not be applied to this exact order.

Features:

  • Sources: Existing verified Triconex model documentation and saved model PDFs
  • Use complete equipment instructions for installation and commissioning.
  • Accessories are supplied only when listed in the quotation
Documentation for the 3511 is supplied here as a technical-data extract; confirm manual availability in the written quotation.

Important notice

Manuals, software, firmware, cables, calibration data and accessories are included only when listed in the quotation. AMIKON is an independent supplier and is not affiliated with or authorised by the manufacturer.
This content has been produced using multiple sources. Takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
BUYER INFORMATION

Commercial terms without hidden steps

Your written quote confirms the product identity, price, availability, lead time, warranty and shipping terms before payment.
  • 01

    Shipping & delivery

    Dispatch
    Eligible stock: same / next day
    Carriers
    DHL, FedEx or UPS
    Ship from
    Xiamen, China
    Packed size
    49 × 45.3 × 6.8 cm
    Shipping weight
    2.95 kg
  • 02

    Payment & customs

    Payment
    Bank transfer (T/T)
    Currencies
    USD · EUR · GBP · RMB
    Credit cards
    Not accepted
    HS reference
    8537101190
    Origin
    USA
  • 03

    Warranty & returns

    Warranty
    12 months from AMIKON
    Inspection
    Label, condition and packing checks
    Returns
    Prior RMA authorisation required
    Compatibility
    Confirm before order
    OEM warranty
    Does not apply
Your written quote confirms the product identity, price, availability, lead time, warranty and shipping terms before payment.
  • Part checked

    Full suffix recorded
  • Condition checked

    Label and appearance
  • Packing checked

    Antistatic protection
  • Tracking supplied

    Established couriers
  • Sandy Lin

    Dedicated account manager · 15+ years
FREQUENTLY ASKED QUESTIONS

Questions buyers ask about 3511

Direct answers about identity, compatibility, stock, warranty, payment and shipping.
  • Is 3511 suitable for my speed-monitoring application?

    Use 3511 for eight non-commoned, AC-coupled differential pulse inputs from supported non-amplified magnetic speed sensors. Confirm the required 20 Hz to 20,000 Hz range and signal levels.
  • Can 3511 directly replace another pulse-input module?

    Do not decide from the connector or channel count alone. Match the exact 3511 model, eight-input configuration, frequency range, slot keys 004/001, termination and application scaling.
  • What should an MRO buyer provide for an urgent 3511 quotation?

    Provide the exact model, quantity, label and connector photos, chassis and slot, sensor model, expected frequency and amplitude, termination details, fault indications and destination country.
  • Which sensor signals should a system integrator confirm for 3511?

    Confirm an AC-coupled, balanced differential signal from a supported non-amplified magnetic speed sensor. Check impedance, normal-mode and common-mode limits before connection.
  • What should be checked when 3511 arrives?

    Inspect the label, connector pins, slot keys, housing and front indicators. Compare the module and termination arrangement with the installed unit before disconnecting field wiring.
  • How should field wiring for 3511 be checked?

    Verify channel polarity, pair separation, shielding, grounding and termination. Keep the pulse signal within the documented electrical limits and avoid routing it with high-noise power wiring.
  • What should be tested after installing 3511?

    Verify PASS, FAULT and ACTIVE status, all required input-activity indicators, measured frequency, application scaling and channel diagnostics across the operating speed range.
  • What should engineers check if 3511 shows unstable or missing speed?

    Check sensor output amplitude, polarity, shield termination, common-mode voltage, field connections and configured scaling. Compare the input with a known frequency source before changing the module.
READY TO VERIFY YOUR PART?

Get a 3511 quote with price, lead time and revision check.

Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, drives and servo motors, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: Amikon Limited sells new and surplus products and develops channels for purchasing such products. Amikon Limited is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because Amikon Limited is not an authorized distributor of this product, the Original Manufacturer's warranty does not apply. Amikon Limited is not an authorized distributor, dealer, or representative of the products displayed on this website. All product names, trademarks, brands, and logos used on this website are the property of their respective owners. The description, explanation, or sale of products with these names, trademarks, brands, and logos is for identification purposes only and is not intended to indicate any association with or authorization from any rights holder.