Close Menu
Get Parts Quote
Name
Company *
WhatsApp / WeChat (For Faster Quote) *
Email *
Address
City
State / Province / Region
Zipcode
Country
Quantity *
Part Number *
Manufacturer
Preferred Condition
Additional Information
Cancel
In Stock
Fast Shipping Available
ABB AI562
· Product image is representative; revision or series may vary. Contact us to request a specific version.
Ships by Thursday, September 10

AI562

Two-channel RTD Input Module

Shipping Information

  • For inventory products, we support same day shipping upon payment.
  • For urgent needs, we offer same-day shipping on most items for orders placed before 2:00 PM UTC+8 Simply mention your preferred next-day shipping when place the order, and your order will be prioritized to minimize downtime.
  • For indent items, typical turnaround is 1-3 weeks, depending on parts availability and scarcity.
Customs & Documentation
We prepare clear, order-specific documentation for every international shipment, including the commercial invoice, packing list and available product or compliance documents. Before dispatch, our logistics team confirms the consignee details, declared value, shipping terms and destination requirements with you. Tracking information is provided after shipment, helping your team prepare for import clearance with confidence.
Documents checked before dispatch · Shipment details confirmed · Global tracking provided
Payment
Payment is by bank wire only in RMB/CNY, GBP, EUR or USD. Amikon does not accept credit cards or provide credit terms. Cleared payment is required before shipment unless the written quotation expressly states otherwise.
Product Condition
Factory New These are new and current items that are procured directly from the manufacturer.
New In Sealed Package Parts are new. They have not been used and still have their original package seal intact.
New in Original Package These parts are new. The packages were not originally sealed by their original manufacturer.
Quantity
Mobile *
Country/Region *
E-mail *
Company
Content *
(gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Amikong please read our privacy policy.
  • 20+

    years in automation
  • ISO 9001

    certified quality system
  • 12 months

    amikon warranty
  • 2-hour reply

    from your account manager
  • Success Story

    solutions in action
PRODUCT DESCRIPTION

AI562 acquires two resistance-based sensor signals

ABB AI562 measures two configurable resistance-temperature or resistance inputs in an S500-eCo I/O station. Supported sensor selections include Pt100, Pt1000, Ni100 and Ni1000, with two-wire or three-wire RTD connections.

The module is ordered as 1TNE968902R1102. Its two channels share one isolated group and use a separate 24 V DC process supply. Check the hardware index before applying power-consumption or accuracy figures: ABB distinguishes versions before E0 from E0 and later.
ACTUAL APPLICATIONS

Where AI562 acquires temperature and resistance values

ABB documents two-wire and three-wire RTD circuits alongside dedicated resistance ranges. Choose the acquisition method for the actual sensor and cable arrangement.
  • 01 · LOCAL RTD SENSING

    Measure nearby temperature sensors

    Use a supported two-wire RTD for a short sensor run. Account for the resistance of both leads when assessing the indicated temperature, and select the matching Pt100, Pt1000, Ni100 or Ni1000 configuration.
  • 02 · REMOTE RTD SENSING

    Limit lead effects on remote measurements

    Apply the documented three-wire circuit when longer RTD wiring would introduce unacceptable two-wire lead error. Keep the installation within the permitted cable length and conductor requirements, then compare the channel value with the actual sensor condition.
  • 03 · RESISTANCE ACQUISITION

    Read resistance without temperature scaling

    Select the documented 150 ohm or 300 ohm measuring range for resistance acquisition. Interpret the channel data using that range rather than a temperature curve, and verify the connected resistance and lead-loop limits before commissioning.

Technical specifications for AI562

  • Product Model
    AI562
  • Product Parameters
    Two-channel RTD Input Module
  • In stock
    1 unit
  • Manufacturer
    ABB
  • RTD input channels
    2 configurable inputs in one group
  • Sensor wiring
    2-wire or 3-wire RTD
  • RTD families
    Pt100, Pt1000, Ni100, Ni1000
  • Resistance ranges
    150 ohm and 300 ohm
  • RTD resolution
    0.1 deg C
  • Process supply
    24 V DC; -15% to +20%
  • Process-supply current
    40 mA before E0; 20 mA for E0 or later
  • Maximum power dissipation
    1.1 W before E0; 0.6 W for E0 or later
  • Group isolation
    500 V DC between input group and rest of module
  • Module update time
    All channels less than 1 s
  • Analog conversion time
    Typically 190 ms per channel
  • Input data length
    4 bytes
  • Wire loop resistance
    Less than 20 ohm
  • Sensor power dissipation
    Maximum 1 mW
  • Cable length
    10 m unshielded or 100 m shielded; conductor greater than 0.14 mm2
View all additional

Alternative Names

AI562 1TNE968902R1102 S500-eCo two-channel RTD input
SYSTEM & REPLACEMENT CHECK

Information needed before ordering

Three direct checks to secure your system integration and minimize ordering risks.

Information

System integration Replacement check Manuals & support
S500-eCo RESISTANCE INPUT

Match the RTD circuit and terminal block

AI562 provides two configurable resistance-based input channels in an AC500 S500-eCo installation. The channels use one isolated group; the documented isolation is not independent isolation between both sensor inputs.
The RTD current-source terminals are 10 and 13, sense inputs 11 and 14, and returns 12 and 15. Process power is connected at 19 and 20. Use the exact circuit for the selected two-wire or three-wire sensor, not a generic analog-input diagram.
The removable terminal block is a separately ordered item. Restore channel parameters in the controller project and keep the before-E0 and E0-or-later electrical ratings distinct when checking the cabinet power budget.

Features:

  • Select the actual RTD or resistance range
  • Specify the required 11-pin terminal block
  • Check hardware index and supply budget
The ABB AI562 requires its sensor circuit, terminal allocation and hardware index to be verified before system integration and commissioning.
INTERCHANGEABILITY

Verify the complete replacement identity before commissioning

ABB lists AI562 as Active in datasheet 3ADR010032 revision 14 dated 2026-03-23. This does not make it interchangeable with a voltage, current or thermocouple input module; the actual signal class must match.
Record the terminal-block type, sensor family, wiring method and configured range before exchange. Compare the hardware index because power consumption and specified measurement errors differ between earlier units and E0 or later.
Isolate supply and process voltages before removing the module or its terminals. Following replacement, restore the engineered channel configuration and compare both readings against known sensor conditions before enabling dependent control functions.

Features:

  • Keep the RTD and resistance signal scope
  • Review index-dependent electrical ratings
  • Validate both sensor readings after exchange
The ABB AI562 requires replacement verification of the sensor selection, terminal assignment and controller configuration before commissioning.
DOCUMENTATION STATUS

Browse the Manuals, Datasheets, Official Documents, Links

Important Notice: These Amikon documents identify the applicable ABB source material. Terminal blocks, sensors and field cables are supplied only when expressly included in the quotation.

Features:

  • AI562 hardware-index distinctions are retained in the applicable technical data
  • Software licensing and project backups remain the customer's responsibility
  • Accessories are supplied only when listed in the quotation
Documentation for the ABB AI562 must match the required RTD or resistance circuit and the specified terminal block; confirm manual availability in the written quotation.

Important notice

Manuals, software, firmware, cables, calibration data and accessories are included only when listed in the quotation. AMIKON is an independent supplier and is not affiliated with or authorised by the manufacturer.
This content has been produced using multiple sources. Takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
BUYER INFORMATION

Commercial terms without hidden steps

Your written quote confirms the product identity, price, availability, lead time, warranty and shipping terms before payment.
  • 01

    Shipping & delivery

    Dispatch
    Eligible stock: same / next day
    Carriers
    DHL, FedEx or UPS
    Ship from
    Xiamen, China
    Packed size
    13.4 × 7.3 × 4.3 cm
    Shipping weight
    0.16 kg
  • 02

    Payment & customs

    Payment
    Bank transfer (T/T)
    Currencies
    USD · EUR · GBP · RMB
    Credit cards
    Not accepted
    HS reference
    8538900000
    Origin
    Switzerland
  • 03

    Warranty & returns

    Warranty
    12 months from AMIKON
    Inspection
    Label, condition and packing checks
    Returns
    Prior RMA authorisation required
    Compatibility
    Confirm before order
    OEM warranty
    Does not apply
Your written quote confirms the product identity, price, availability, lead time, warranty and shipping terms before payment.
  • Part checked

    Full suffix recorded
  • Condition checked

    Label and appearance
  • Packing checked

    Antistatic protection
  • Tracking supplied

    Established couriers
  • Sandy Lin

    Dedicated account manager · 15+ years
FREQUENTLY ASKED QUESTIONS

Questions buyers ask about AI562

Direct answers about identity, compatibility, stock, warranty, payment and shipping.
  • Why does a two-wire Pt100 circuit read differently after its cable is extended?

    Lead resistance contributes to the measured resistance in a two-wire circuit. ABB recommends keeping that cable short and using the documented three-wire connection for longer runs to achieve the specified measuring accuracy.
  • Must the RTD connector be ordered separately from AI562?

    Yes. ABB lists the 11-pin TA563-11, TA564-11 and TA565-11 terminal blocks separately. Select the required screw or spring connection and cable direction, and include the terminal block explicitly in the order.
  • How should panel designers budget AI562 power before the hardware index is known?

    Do not assume the lower E0 figures. ABB lists 40 mA process current and 1.1 W maximum module dissipation before E0, compared with 20 mA and 0.6 W for E0 or later. The CPU or interface supply also carries approximately 5 mA for the module.
  • Does 0.1 degree resolution mean the complete temperature measurement is accurate to 0.1 degree?

    No. Resolution is the displayed temperature increment, not total accuracy. Sensor selection, lead resistance, hardware index, ambient conditions and the applicable full-scale error specification must be considered separately.
  • Can the 150 ohm setting be used as a generic 0-10 V input?

    No. AI562 provides RTD and resistance selections, not a general voltage-input range. Use the supported resistance circuit or a separately verified voltage-input module; never connect a voltage source simply because the connector fits.
  • How much controller input space should be reserved for one AI562?

    ABB specifies four input-data bytes for the two-channel module. Map both channel values in the engineered I/O configuration and check the interpretation of the selected sensor range before using them in the control program.
  • Will a sub-second control task receive a new temperature sample on every execution?

    Not necessarily. ABB specifies less than one second for updating all channels and a typical conversion time of 190 ms per channel. A faster controller task can therefore read the same conversion result more than once.
  • What should the technician do with terminal 16 when reusing an old terminal block?

    Leave it unconnected. ABB marks terminal 16 as reserved and warns that reserved terminals may carry internal voltages. Verify the complete terminal assignment with all supply and process power isolated before reconnecting the field wiring.
READY TO VERIFY YOUR PART?

Get a AI562 quote with price, lead time and revision check.

Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, drives and servo motors, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: Amikon Limited sells new and surplus products and develops channels for purchasing such products. Amikon Limited is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because Amikon Limited is not an authorized distributor of this product, the Original Manufacturer's warranty does not apply. Amikon Limited is not an authorized distributor, dealer, or representative of the products displayed on this website. All product names, trademarks, brands, and logos used on this website are the property of their respective owners. The description, explanation, or sale of products with these names, trademarks, brands, and logos is for identification purposes only and is not intended to indicate any association with or authorization from any rights holder.