Close Menu
Get Parts Quote
Name
Company *
WhatsApp / WeChat (For Faster Quote) *
Email *
Address
City
State / Province / Region
Zipcode
Country
Quantity *
Part Number *
Manufacturer
Preferred Condition
Additional Information
Cancel
In Stock
Fast Shipping Available
ABB CI521-MODTCP
· Product image is representative; revision or series may vary. Contact us to request a specific version.
Ships by Thursday, September 10

CI521-MODTCP

Modbus TCP I/O Interface

Shipping Information

  • For inventory products, we support same day shipping upon payment.
  • For urgent needs, we offer same-day shipping on most items for orders placed before 2:00 PM UTC+8 Simply mention your preferred next-day shipping when place the order, and your order will be prioritized to minimize downtime.
  • For indent items, typical turnaround is 1-3 weeks, depending on parts availability and scarcity.
Customs & Documentation
We prepare clear, order-specific documentation for every international shipment, including the commercial invoice, packing list and available product or compliance documents. Before dispatch, our logistics team confirms the consignee details, declared value, shipping terms and destination requirements with you. Tracking information is provided after shipment, helping your team prepare for import clearance with confidence.
Documents checked before dispatch · Shipment details confirmed · Global tracking provided
Payment
Payment is by bank wire only in RMB/CNY, GBP, EUR or USD. Amikon does not accept credit cards or provide credit terms. Cleared payment is required before shipment unless the written quotation expressly states otherwise.
Product Condition
Factory New These are new and current items that are procured directly from the manufacturer.
New In Sealed Package Parts are new. They have not been used and still have their original package seal intact.
New in Original Package These parts are new. The packages were not originally sealed by their original manufacturer.
Quantity
Mobile *
Country/Region *
E-mail *
Company
Content *
(gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Amikong please read our privacy policy.
  • 20+

    years in automation
  • ISO 9001

    certified quality system
  • 12 months

    amikon warranty
  • 2-hour reply

    from your account manager
  • Success Story

    solutions in action
PRODUCT DESCRIPTION

CI521-MODTCP connects mixed field signals over Modbus TCP

ABB CI521-MODTCP combines analog acquisition, analog commands and discrete field signals in a Modbus TCP remote I/O station. Four analog inputs and two analog outputs accompany eight digital inputs and eight transistor outputs, supporting mixed-signal equipment through one interface.

Order number 1SAP222100R0001 identifies the standard CI521-MODTCP. Match the sensor ranges, output loads, terminal unit and register configuration to the installation. ABB lists this version as Active in datasheet 3ADR010003 revision 14; the separately ordered XC version has different environmental conditions.
ACTUAL APPLICATIONS

Where CI521-MODTCP connects mixed process signals

ABB documents resistance-temperature inputs, current-source connections and analog output loads. Select the circuit and parameters for each real field task.
  • 01 · TEMPERATURE INPUT

    Read resistance-based temperature sensors

    Acquire supported Pt100, Pt1000 or Ni1000 signals through the documented ABB sensor connection. Select the matching input mode and wiring arrangement, then check the indicated temperature against a known reference while allowing for the slower RTD conversion cycle.
  • 02 · TRANSMITTER INPUT

    Collect current-loop measurements

    Receive active or passive current-source signals using the appropriate ABB input circuit. Provide the correct loop supply and signal return, select the measuring range and validate the acquired value against the transmitter before enabling the associated control action.
  • 03 · ANALOG COMMANDS

    Command compatible analog receivers

    Connect voltage- or current-controlled loads to the corresponding analog output circuit. Match the selected range and receiver impedance, then test the commanded endpoints and actual field response so the electrical command agrees with the intended equipment behavior.

Technical specifications for CI521-MODTCP

  • Product Model
    CI521-MODTCP
  • Product Parameters
    Modbus TCP I/O Interface
  • In stock
    1 unit
  • Manufacturer
    ABB
  • Integrated I/O allocation
    4 analog inputs, 2 analog outputs, 8 digital inputs and 8 digital outputs
  • Ethernet hardware
    10/100 Base-TX; internal switch with two RJ45 sockets
  • Process data structure
    20 input bytes and 24 output bytes
  • Process supply
    24 V DC at UP and UP3; -15% / +20% system tolerance
  • Normal UP current
    0.20 A
  • UP3 current demand
    0.06 A plus maximum 0.5 A per output
  • Internal power dissipation
    Maximum 6 W
  • Analog input modes
    0-10 V, +/-10 V, 0/4-20 mA, Pt100, Pt1000 and Ni1000
  • Analog conversion cycle
    1 ms for 4 inputs and 2 outputs; 1 s with RTDs
  • Analog conversion resolution
    Voltage/current: 12 bits; bipolar voltage includes sign; RTD: 0.1 deg C
  • Analog input impedance
    Voltage >100 kohm; current approximately 330 ohm
  • Analog output ranges
    +/-10 V, 0-20 mA and 4-20 mA; individually configurable
  • Current-output load range
    0-500 ohm
  • Digital input filtering
    Typically 0.1 ms; configurable 0.1-32 ms
  • Digital output load capacity
    500 mA per channel; 4 A total before installation derating
View all additional

Alternative Names

CI521-MODTCP 1SAP222100R0001 CI521 Modbus TCP interface
SYSTEM & REPLACEMENT CHECK

Information needed before ordering

Three direct checks to secure your system integration and minimize ordering risks.

Information

System integration Replacement check Manuals & support
MODBUS MIXED-SIGNAL STATION

Match sensor modes, output circuits and register mapping

ABB CI521-MODTCP combines analog acquisition, analog commands and discrete field signals in a Modbus TCP remote I/O station. Four analog inputs and two analog outputs accompany eight digital inputs and eight transistor outputs, supporting mixed-signal equipment through one interface.
CI521-MODTCP uses a TU507-ETH or TU508-ETH terminal unit. Its analog and digital banks have different connection requirements; preserve the correct signal reference for every configured mode.
Configure the IP address, process-image mapping and allowed write clients in the engineered system. Test the timeout response and retain the exact expansion-module order with the controller project.

Features:

  • Identify order 1SAP222100R0001
  • Confirm analog modes and receiver circuits
  • Record register addresses and write supervision
The ABB CI521-MODTCP requires a verified mixed-signal circuit and Modbus configuration before system integration and commissioning.
INTERCHANGEABILITY

Verify the complete replacement identity before commissioning

ABB lists standard CI521-MODTCP order 1SAP222100R0001 as Active in revision 14 dated 2025-11-28. Confirm the installed standard or XC identity instead of assuming the environmental variants are interchangeable.
Preserve the module parameters, IP settings, expansion order, register map and approved write-client list. Check older expansion-module firmware where independent power-up timing is involved.
Isolate the interface before replacement. After restoring its settings, compare measured inputs and commanded outputs with the field equipment, then test the configured bus-failure response before returning to service.

Features:

  • Match standard model and complete order number
  • Retain register map and channel configuration
  • Validate process response after exchange
The ABB CI521-MODTCP requires replacement verification of its mixed-signal wiring, Modbus mapping and fault behavior before commissioning.
DOCUMENTATION STATUS

Browse the Manuals, Datasheets, Official Documents, Links

Important Notice: These Amikon documents identify the applicable ABB source edition. Controllers, terminal units and field accessories are included only when expressly listed in the quotation.

Features:

  • CI521-MODTCP documentation covers mixed analog and digital Modbus I/O
  • Software licensing and project backups remain the customer's responsibility
  • Accessories are supplied only when listed in the quotation
Documentation for the ABB CI521-MODTCP must match the required signal circuits and network configuration; confirm manual availability in the written quotation.

Important notice

Manuals, software, firmware, cables, calibration data and accessories are included only when listed in the quotation. AMIKON is an independent supplier and is not affiliated with or authorised by the manufacturer.
This content has been produced using multiple sources. Takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
BUYER INFORMATION

Commercial terms without hidden steps

Your written quote confirms the product identity, price, availability, lead time, warranty and shipping terms before payment.
  • 01

    Shipping & delivery

    Dispatch
    Eligible stock: same / next day
    Carriers
    DHL, FedEx or UPS
    Ship from
    Xiamen, China
    Packed size
    13.4 × 7.3 × 4.3 cm
    Shipping weight
    0.16 kg
  • 02

    Payment & customs

    Payment
    Bank transfer (T/T)
    Currencies
    USD · EUR · GBP · RMB
    Credit cards
    Not accepted
    HS reference
    8538900000
    Origin
    Switzerland
  • 03

    Warranty & returns

    Warranty
    12 months from AMIKON
    Inspection
    Label, condition and packing checks
    Returns
    Prior RMA authorisation required
    Compatibility
    Confirm before order
    OEM warranty
    Does not apply
Your written quote confirms the product identity, price, availability, lead time, warranty and shipping terms before payment.
  • Part checked

    Full suffix recorded
  • Condition checked

    Label and appearance
  • Packing checked

    Antistatic protection
  • Tracking supplied

    Established couriers
  • Sandy Lin

    Dedicated account manager · 15+ years
FREQUENTLY ASKED QUESTIONS

Questions buyers ask about CI521-MODTCP

Direct answers about identity, compatibility, stock, warranty, payment and shipping.
  • Why can Modbus polling remain active while the output watchdog expires?

    The timeout supervises write telegrams, starting after the first write. Reading registers alone does not refresh it; keep the configured write cycle within the timeout.
  • How can a maintenance client read values without permission to change outputs?

    Configure the permitted Master IP entries. Once at least one writer is specified, only listed clients may write; other clients retain read access. This is not a replacement for network security controls.
  • What is the purpose of the dummy output register?

    ABB provides it to retrigger bus supervision without changing physical outputs. Use the documented register and function code for the selected mapping; it is not an additional wired output.
  • Must every data type be byte-swapped for a big-endian controller?

    No. ABB requires BYTE and DWORD data to be swapped when interfacing with a big-endian controller, but not analog values. Follow the published process structure instead of swapping the entire image uniformly.
  • Why does an unwired analog terminal indicate a high value?

    ABB uses a high-resistance pull-up for open-circuit detection, so an unconnected analog input can read maximum voltage. Check wiring and channel configuration before treating it as a process excursion.
  • Can older expansion modules power up later than the interface?

    ABB requires attached expansion modules with firmware 1.9 or earlier to power up together with CI52x. Check the hardware index against ABB's compatibility table before using separate power-up timing.
  • Will inserting a module preserve downstream addresses with dynamic mapping?

    Not necessarily. Dynamic mapping follows the actual configuration, so downstream addresses depend on preceding I/O sizes. Read the device information registers and update the controller mapping after configuration changes.
  • Is a 1 ms analog cycle maintained when a resistance thermometer is selected?

    No. ABB lists a 1 ms cycle for the four inputs and two outputs, but 1 s with Pt/Ni resistance-temperature measurement. Account for the selected mode in the required measurement response.
READY TO VERIFY YOUR PART?

Get a CI521-MODTCP quote with price, lead time and revision check.

Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, drives and servo motors, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: Amikon Limited sells new and surplus products and develops channels for purchasing such products. Amikon Limited is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because Amikon Limited is not an authorized distributor of this product, the Original Manufacturer's warranty does not apply. Amikon Limited is not an authorized distributor, dealer, or representative of the products displayed on this website. All product names, trademarks, brands, and logos used on this website are the property of their respective owners. The description, explanation, or sale of products with these names, trademarks, brands, and logos is for identification purposes only and is not intended to indicate any association with or authorization from any rights holder.