Close Menu
Get Parts Quote
Name
Company *
WhatsApp / WeChat (For Faster Quote) *
Email *
Address
City
State / Province / Region
Zipcode
Country
Quantity *
Part Number *
Manufacturer
Preferred Condition
Additional Information
Cancel
In Stock
Fast Shipping Available
ABB DI562
· Product image is representative; revision or series may vary. Contact us to request a specific version.
Ships by Thursday, September 10

DI562

AC DC Input Module

Shipping Information

  • For inventory products, we support same day shipping upon payment.
  • For urgent needs, we offer same-day shipping on most items for orders placed before 2:00 PM UTC+8 Simply mention your preferred next-day shipping when place the order, and your order will be prioritized to minimize downtime.
  • For indent items, typical turnaround is 1-3 weeks, depending on parts availability and scarcity.
Customs & Documentation
We prepare clear, order-specific documentation for every international shipment, including the commercial invoice, packing list and available product or compliance documents. Before dispatch, our logistics team confirms the consignee details, declared value, shipping terms and destination requirements with you. Tracking information is provided after shipment, helping your team prepare for import clearance with confidence.
Documents checked before dispatch · Shipment details confirmed · Global tracking provided
Payment
Payment is by bank wire only in RMB/CNY, GBP, EUR or USD. Amikon does not accept credit cards or provide credit terms. Cleared payment is required before shipment unless the written quotation expressly states otherwise.
Product Condition
Factory New These are new and current items that are procured directly from the manufacturer.
New In Sealed Package Parts are new. They have not been used and still have their original package seal intact.
New in Original Package These parts are new. The packages were not originally sealed by their original manufacturer.
Quantity
Mobile *
Country/Region *
E-mail *
Company
Content *
(gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Amikong please read our privacy policy.
  • 20+

    years in automation
  • ISO 9001

    certified quality system
  • 12 months

    amikon warranty
  • 2-hour reply

    from your account manager
  • Success Story

    solutions in action
PRODUCT DESCRIPTION

DI562 collects AC and DC discrete field signals

ABB DI562 acquires sixteen 24 V AC or DC digital signals in two isolated eight-channel groups. The S500-eCo module supports the documented source, sink and AC input arrangements, with signal-state indication for each channel.

Order 1TNE968902R2102 identifies DI562. Match the group reference connections, terminal blocks and signal type to the field devices. For hardware versions before E0, ABB requires external surge-limiting filters when the inputs are used with 24 V AC.
ACTUAL APPLICATIONS

Where DI562 acquires distinct switching signals

ABB specifies source, sink and AC input arrangements. Select the applicable circuit for each engineered group and observe the hardware-revision conditions; these are integration scenarios, not named customer cases.
  • 01 · AC FIELD STATUS

    Acquire compatible 24 V AC signals

    Monitor discrete AC field states within the documented frequency and voltage ranges. Check the actual hardware revision before connecting the circuit, including the external surge-filter requirement before E0. Validate the received state at the controller using the installed signal source.
  • 02 · POSITIVE DC INPUT

    Read positive-polarity switching circuits

    Connect compatible positive DC switching signals using the documented group reference and terminal allocation. Check the actual source and input current together with off-state leakage. Compare the controller state with the field device during a controlled input test.
  • 03 · NEGATIVE DC INPUT

    Integrate negative-polarity field circuits

    Use the specified negative DC signal arrangement where the field circuit requires it. Identify the common reference for the relevant eight-channel group and preserve that polarity in the wiring schedule. Verify each signal against the negative-input range before releasing the station.

Technical specifications for DI562

  • Product Model
    DI562
  • Product Parameters
    AC DC Input Module
  • In stock
    1 unit
  • Manufacturer
    ABB
  • Input-channel count
    16 digital inputs
  • Galvanic isolation
    Two isolated eight-channel groups; isolated from the remainder of the module
  • Supported signal arrangements
    Type 1 source, Type 1 sink and Type 1 AC according to EN 61131-2
  • Nominal input signals
    -24 V DC, +24 V DC or 24 V AC at 50/60 Hz
  • High-state ranges
    Negative DC: -30 to -15 V; positive DC: +15 to +30 V; AC: 14-27 V AC
  • Typical input current at 24 V
    5 mA DC or 5 mA rms AC per channel
  • Two-wire proximity-switch leakage
    Maximum 1 mA DC or typically 1 mA rms AC as specified
  • Input transition delay
    Typically 8 ms for either transition
  • Input data length
    2 bytes
  • Host-side supply consumption
    Approximately 5 mA from CPU or communication-interface supply
  • Internal power dissipation
    Maximum 3.2 W
  • Signal cable length
    Maximum 500 m shielded or 300 m unshielded
  • Operating ambient
    Horizontal: 0-60 C; vertical: 0-40 C
  • Humidity limit
    Maximum 95%, without condensation
  • Housing flammability classification
    UL 94 V-0
View all additional

Alternative Names

DI562 1TNE968902R2102 DI562 16-channel AC DC input
SYSTEM & REPLACEMENT CHECK

Information needed before ordering

Three direct checks to secure your system integration and minimize ordering risks.

Information

System integration Replacement check Manuals & support
S500-ECO DISCRETE ACQUISITION

Match field polarity, group references and input mapping

ABB DI562 acquires sixteen 24 V AC or DC digital signals in two isolated eight-channel groups. The S500-eCo module supports the documented source, sink and AC input arrangements, with signal-state indication for each channel.
The first and second eight-channel groups use different reference terminals. The documented source, sink and AC arrangements have distinct voltage criteria; retain the selected circuit in the field-wiring record.
The input image occupies two bytes. Check terminal-block identity, hardware revision and any required AC surge filters before commissioning, then verify the sixteen controller states against the physical signals.

Features:

  • Match order 1TNE968902R2102
  • Identify each eight-channel reference circuit
  • Check pre-E0 AC protection requirements
The ABB DI562 requires a validated signal-polarity arrangement and input map before system integration and commissioning.
INTERCHANGEABILITY

Verify the complete replacement identity before commissioning

ABB lists DI562 order 1TNE968902R2102 as Active in datasheet revision 12 dated 2024-11-15. Use the exact module identity and actual hardware revision when reviewing an installed replacement.
Preserve the two-byte input map, group reference polarity, terminal-block variants and field-wiring schedule. Inspect older AC installations for the pre-E0 external surge-filter requirement before fitting the replacement.
Replace with circuits isolated and retain the appropriate cabinet airflow and temperature conditions. Test each field state and its controller indication before the equipment returns to operation.

Features:

  • Record the actual DI562 hardware revision
  • Preserve group references and input mapping
  • Test AC or DC field states after replacement
The ABB DI562 requires replacement verification of its signal arrangement, revision-dependent AC protection and terminal connections before commissioning.
DOCUMENTATION STATUS

Browse the Manuals, Datasheets, Official Documents, Links

Important Notice: The Amikon documents identify the ABB source edition and its hardware-revision condition. Terminal blocks and external protection accessories are included only when listed in the quotation.

Features:

  • DI562 documents distinguish AC, source and sink input conditions
  • Software licensing and project backups remain the customer's responsibility
  • Accessories are supplied only when listed in the quotation
Documentation for the ABB DI562 must match the field-input arrangement and any revision-dependent protection; confirm manual availability in the written quotation.

Important notice

Manuals, software, firmware, cables, calibration data and accessories are included only when listed in the quotation. AMIKON is an independent supplier and is not affiliated with or authorised by the manufacturer.
This content has been produced using multiple sources. Takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
BUYER INFORMATION

Commercial terms without hidden steps

Your written quote confirms the product identity, price, availability, lead time, warranty and shipping terms before payment.
  • 01

    Shipping & delivery

    Dispatch
    Eligible stock: same / next day
    Carriers
    DHL, FedEx or UPS
    Ship from
    Xiamen, China
    Packed size
    13.4 × 7.3 × 4.3 cm
    Shipping weight
    0.16 kg
  • 02

    Payment & customs

    Payment
    Bank transfer (T/T)
    Currencies
    USD · EUR · GBP · RMB
    Credit cards
    Not accepted
    HS reference
    8538900000
    Origin
    Switzerland
  • 03

    Warranty & returns

    Warranty
    12 months from AMIKON
    Inspection
    Label, condition and packing checks
    Returns
    Prior RMA authorisation required
    Compatibility
    Confirm before order
    OEM warranty
    Does not apply
Your written quote confirms the product identity, price, availability, lead time, warranty and shipping terms before payment.
  • Part checked

    Full suffix recorded
  • Condition checked

    Label and appearance
  • Packing checked

    Antistatic protection
  • Tracking supplied

    Established couriers
  • Sandy Lin

    Dedicated account manager · 15+ years
FREQUENTLY ASKED QUESTIONS

Questions buyers ask about DI562

Direct answers about identity, compatibility, stock, warranty, payment and shipping.
  • Why does an older DI562 used with 24 V AC need an additional hardware check?

    ABB requires external surge-limiting filters for AC input use on versions before E0. Inspect the actual hardware revision and installed protection rather than assuming every DI562 has the same AC installation requirements.
  • Does the two-byte input length apply to each DI562 channel?

    No. ABB lists two bytes for the module input data length. Map the sixteen digital states to the documented module input image, not two bytes for each channel.
  • Must a DI562 group reference always connect to the negative supply pole?

    No. ABB permits the positive or negative process-supply pole as the reference for the documented source or sink arrangement. Terminals 1 and 10 are the references for the two groups; match polarity to the actual switching circuit.
  • Does six pieces per unit in the terminal-block ordering table mean six input channels?

    No. It describes the sales quantity of the listed terminal-block accessory. DI562 itself has sixteen inputs and needs the specified nine-pin and eleven-pin block arrangement.
  • Can the positive DC high-state range be used as the AC acceptance range?

    No. ABB lists +15 to +30 V for positive DC but 14 to 27 V AC for AC high. Evaluate the applied signal against the correct AC or DC column, not a combined nominal 24 V label.
  • Is the input-side AC signal the power source for DI562 electronics?

    ABB states that the module is powered through the I/O bus and draws approximately 5 mA from the CPU or communication-interface supply. Distinguish that internal power path from the AC or DC field-input circuit.
  • Should the documented 1.2 Nm mounting torque be applied to every signal terminal screw?

    No. The value appears with M4 mounting in the mechanical data. Select terminal-block tightening requirements from the applicable accessory instructions rather than transferring a mounting-screw value to signal terminals.
  • Can DI562 be fitted to either common 35 mm top-hat rail depth?

    The mechanical data specifies an IEC 60715 35 mm rail with a depth of 7.5 mm or 15 mm. Confirm the actual mounting clearances and cabinet installation for the selected rail.
READY TO VERIFY YOUR PART?

Get a DI562 quote with price, lead time and revision check.

Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, drives and servo motors, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: Amikon Limited sells new and surplus products and develops channels for purchasing such products. Amikon Limited is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because Amikon Limited is not an authorized distributor of this product, the Original Manufacturer's warranty does not apply. Amikon Limited is not an authorized distributor, dealer, or representative of the products displayed on this website. All product names, trademarks, brands, and logos used on this website are the property of their respective owners. The description, explanation, or sale of products with these names, trademarks, brands, and logos is for identification purposes only and is not intended to indicate any association with or authorization from any rights holder.