Close Menu
Get Parts Quote
Name
Company *
WhatsApp / WeChat (For Faster Quote) *
Email *
Address
City
State / Province / Region
Zipcode
Country
Quantity *
Part Number *
Manufacturer
Preferred Condition
Additional Information
Cancel
In Stock
Fast Shipping Available
ABB DO562
· Product image is representative; revision or series may vary. Contact us to request a specific version.
Ships by Saturday, September 19

DO562

Transistor Digital Output Module

Shipping Information

  • For inventory products, we support same day shipping upon payment.
  • For urgent needs, we offer same-day shipping on most items for orders placed before 2:00 PM UTC+8 Simply mention your preferred next-day shipping when place the order, and your order will be prioritized to minimize downtime.
  • For indent items, typical turnaround is 1-3 weeks, depending on parts availability and scarcity.
Customs & Documentation
We prepare clear, order-specific documentation for every international shipment, including the commercial invoice, packing list and available product or compliance documents. Before dispatch, our logistics team confirms the consignee details, declared value, shipping terms and destination requirements with you. Tracking information is provided after shipment, helping your team prepare for import clearance with confidence.
Documents checked before dispatch · Shipment details confirmed · Global tracking provided
Payment
Payment is by bank wire only in RMB/CNY, GBP, EUR or USD. Amikon does not accept credit cards or provide credit terms. Cleared payment is required before shipment unless the written quotation expressly states otherwise.
Product Condition
Factory New These are new and current items that are procured directly from the manufacturer.
New In Sealed Package Parts are new. They have not been used and still have their original package seal intact.
New in Original Package These parts are new. The packages were not originally sealed by their original manufacturer.
Quantity
Mobile *
Country/Region *
E-mail *
Company
Content *
(gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Amikong please read our privacy policy.
  • 20+

    years in automation
  • ISO 9001

    certified quality system
  • 12 months

    amikon warranty
  • 2-hour reply

    from your account manager
  • Success Story

    solutions in action
PRODUCT DESCRIPTION

DO562 switches sixteen protected external load circuits

ABB DO562 provides sixteen 24 V DC transistor outputs in one isolated group. Each channel is rated at 0.5 A, with an 8 A group limit and a two-byte output image for the controller.

Order 1SAP230900R0000 identifies DO562. These outputs are not short-circuit or overload protected. ABB requires external fast-acting fuses and external demagnetization for inductive loads; do not parallel channels or apply external voltage to an output.
ACTUAL APPLICATIONS

Where DO562 controls engineered DC loads

ABB documents resistive, inductive and lamp-load limits. These scenarios require suitable external protection and verified field wiring; they are not named customer case studies.
  • 01 · INDUCTIVE LOADS

    Switch loads with external suppression

    Operate compatible inductive DC loads only with individually engineered demagnetization and the required channel fuses. Respect the 0.5 Hz limit and channel current rating. Verify the discharge path and commanded load response before releasing the sequence.
  • 02 · LAMP INDICATION

    Control low-power DC indication

    Switch compatible lamp loads within the documented 5 W rating and 11 Hz maximum frequency. Include the external fault protection and evaluate the actual lamp circuit. Confirm the indication behavior at both commanded states without backfeeding the output.
  • 03 · RESISTIVE DC LOADS

    Drive separate resistive circuits

    Control independently wired resistive loads within the per-channel and group ratings. Keep outputs separate rather than combining them for a larger load. Account for cabinet orientation, external fusing and the different turn-on and turn-off delay limits.

Technical specifications for DO562

  • Product Model
    DO562
  • Product Parameters
    Transistor Digital Output Module
  • In stock
    1 unit
  • Manufacturer
    ABB
  • Output-channel count
    16 transistor digital outputs
  • Output isolation
    One isolated group of 16 channels; isolated from the remainder of the module
  • Rated output voltage
    24 V DC
  • Rated load current
    0.5 A per output; 8 A maximum for the group
  • Minimum high-state voltage
    UP minus 0.3 V at maximum load
  • Off-state leakage
    Maximum 0.5 mA
  • Rated-load transition delays
    Maximum 50 microseconds on; maximum 200 microseconds off
  • Lamp-load rating
    Maximum 5 W per output
  • Load switching frequencies
    Inductive: maximum 0.5 Hz; lamp: maximum 11 Hz at 5 W
  • Output data length
    2 bytes
  • Protection requirements
    External 3 A fast-acting fuse per output; external demagnetization for inductive loads
  • Feedback and parallel operation
    External 24 V feedback not permitted; output paralleling not permitted
  • Internal power dissipation
    Maximum 1.4 W
  • Signal cable length
    Maximum 500 m shielded or 150 m unshielded
  • Operating ambient
    Horizontal: 0-60 C; vertical: 0-40 C with 50% digital-output derating
View all additional

Alternative Names

DO562 1SAP230900R0000 DO562 16-channel transistor output
SYSTEM & REPLACEMENT CHECK

Information needed before ordering

Three direct checks to secure your system integration and minimize ordering risks.

Information

System integration Replacement check Manuals & support
S500-ECO OUTPUT CONTROL

Engineer protection outside the output module

ABB DO562 provides sixteen 24 V DC transistor outputs in one isolated group. Each channel is rated at 0.5 A, with an 8 A group limit and a two-byte output image for the controller.
DO562 outputs do not provide short-circuit protection, overload protection or an overload message. External fast-acting fuses and load-specific suppression are essential parts of the circuit design.
Maintain a two-byte output map and separate output conductors. Check orientation-dependent derating, lamp and inductive switching limits, and the prohibition on output paralleling or external feedback.

Features:

  • Match order 1SAP230900R0000
  • Inspect external fuses and load suppression
  • Validate output mapping and independent wiring
The ABB DO562 requires external output protection and validated load circuits before system integration and commissioning.
INTERCHANGEABILITY

Verify the complete replacement identity before commissioning

ABB lists DO562 order 1SAP230900R0000 as Active in datasheet revision 14 dated 2025-11-28. Record the installed order identity and terminal-block arrangement before replacement.
Retain the two-byte output mapping, external fuses and inductive-load suppression. Review the actual loads against the per-channel, group and orientation-dependent limits; do not transfer assumptions about internally protected outputs.
Isolate the circuit for replacement and inspect for external backfeed or paralleled channels. Restore operation only after the required protection and each commanded load response have been checked.

Features:

  • Record the DO562 order identity
  • Preserve external protection and output mapping
  • Check every load circuit before operation
The ABB DO562 requires replacement verification of its external protection, load ratings and independent output connections before commissioning.
DOCUMENTATION STATUS

Browse the Manuals, Datasheets, Official Documents, Links

Important Notice: The Amikon documents identify ABB revision 14 and its external output-protection requirements. Terminal blocks, fuses and suppression components are included only when stated in the quotation.

Features:

  • DO562 documentation distinguishes supply protection from output protection
  • Software licensing and project backups remain the customer's responsibility
  • Accessories are supplied only when listed in the quotation
Documentation for the ABB DO562 must be used with the documented external protection and load limits; confirm manual availability in the written quotation.

Important notice

Manuals, software, firmware, cables, calibration data and accessories are included only when listed in the quotation. AMIKON is an independent supplier and is not affiliated with or authorised by the manufacturer.
This content has been produced using multiple sources. Takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
BUYER INFORMATION

Commercial terms without hidden steps

Your written quote confirms the product identity, price, availability, lead time, warranty and shipping terms before payment.
  • 01

    Shipping & delivery

    Dispatch
    Eligible stock: same / next day
    Carriers
    DHL, FedEx or UPS
    Ship from
    Xiamen, China
    Packed size
    13.4 × 7.3 × 4.3 cm
    Shipping weight
    0.16 kg
  • 02

    Payment & customs

    Payment
    Bank transfer (T/T)
    Currencies
    USD · EUR · GBP · RMB
    Credit cards
    Not accepted
    HS reference
    8538900000
    Origin
    Switzerland
  • 03

    Warranty & returns

    Warranty
    12 months from AMIKON
    Inspection
    Label, condition and packing checks
    Returns
    Prior RMA authorisation required
    Compatibility
    Confirm before order
    OEM warranty
    Does not apply
Your written quote confirms the product identity, price, availability, lead time, warranty and shipping terms before payment.
  • Part checked

    Full suffix recorded
  • Condition checked

    Label and appearance
  • Packing checked

    Antistatic protection
  • Tracking supplied

    Established couriers
  • Sandy Lin

    Dedicated account manager · 15+ years
FREQUENTLY ASKED QUESTIONS

Questions buyers ask about DO562

Direct answers about identity, compatibility, stock, warranty, payment and shipping.
  • Will DO562 report an output overload so software can replace the external protection?

    No. ABB lists neither an overload message nor internal output current limiting. The required external protection must be engineered independently of the PLC application; software observation is not a substitute for it.
  • Can two DO562 outputs be joined to operate a one-ampere load?

    No. ABB explicitly does not permit paralleling two outputs. Use a suitable separately engineered interface for a load that exceeds the 0.5 A channel rating.
  • Where must the inductive-load discharge energy be handled with DO562?

    ABB requires external demagnetization individually for each inductive load. Do not assume an internal suppression circuit absorbs that energy; select the external suppression and switching duty for the actual load.
  • May an external manual switch apply 24 V directly to a DO562 output terminal?

    No. The datasheet states that resistance to 24 V feedback is not provided. An external control path must not drive voltage back into the module output.
  • Are turn-on and turn-off delays symmetrical for DO562?

    No. At rated load ABB specifies a maximum of 50 microseconds for a zero-to-one transition and 200 microseconds for a one-to-zero transition. Account for the different limits when evaluating a switching sequence.
  • Can a vertical DO562 installation use the full horizontal output-current allowance?

    No. ABB specifies vertical operation from 0 to 40 C with 50% digital-output derating. Apply both the temperature and current conditions for the actual orientation.
  • Does the 11 Hz lamp figure also permit inductive loads to switch at 11 Hz?

    No. The 11 Hz value applies to a 5 W lamp load. ABB separately limits inductive loads to 0.5 Hz; choose the correct load-specific limit.
  • Does reverse-polarity protection of the DO562 supply protect every output fault?

    No. The supply specification and output fault protection are different functions. ABB lists supply reverse-polarity protection but states that the outputs are not short-circuit or overload proof and require external fuses.
READY TO VERIFY YOUR PART?

Get a DO562 quote with price, lead time and revision check.

Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, drives and servo motors, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: Amikon Limited sells new and surplus products and develops channels for purchasing such products. Amikon Limited is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because Amikon Limited is not an authorized distributor of this product, the Original Manufacturer's warranty does not apply. Amikon Limited is not an authorized distributor, dealer, or representative of the products displayed on this website. All product names, trademarks, brands, and logos used on this website are the property of their respective owners. The description, explanation, or sale of products with these names, trademarks, brands, and logos is for identification purposes only and is not intended to indicate any association with or authorization from any rights holder.
Product

Product Browsing History