ABB NIMP01
ABB NIMP01
ABB NIMP01
ABB NIMP01
ABB NIMP01
ABB NIMP01
· Product image is representative; revision or series may vary. Contact us to request a specific version.
Ships by Monday, November 16

NIMP01

Multifunction Processor Termination Module

Shipping Information

  • For inventory products, we support same day shipping upon payment.
  • For urgent needs, we offer same-day shipping on most items for orders placed before 2:00 PM UTC+8 Simply mention your preferred next-day shipping when place the order, and your order will be prioritized to minimize downtime.
  • For indent items, typical turnaround is 1-3 weeks, depending on parts availability and scarcity.
Customs & Documentation
We prepare clear, order-specific documentation for every international shipment, including the commercial invoice, packing list and available product or compliance documents. Before dispatch, our logistics team confirms the consignee details, declared value, shipping terms and destination requirements with you. Tracking information is provided after shipment, helping your team prepare for import clearance with confidence.
Documents checked before dispatch · Shipment details confirmed · Global tracking provided
Payment
Payment is by bank wire only in RMB/CNY, GBP, EUR or USD. Amikon does not accept credit cards or provide credit terms. Cleared payment is required before shipment unless the written quotation expressly states otherwise.
Product Condition
Factory New These are new and current items that are procured directly from the manufacturer.
New In Sealed Package Parts are new. They have not been used and still have their original package seal intact.
New in Original Package These parts are new. The packages were not originally sealed by their original manufacturer.
Quantity
Mobile *
Country/Region *
E-mail *
Company
Content *
(gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Amikong please read our privacy policy.
  • 20+

    years in automation
  • ISO 9001

    certified quality system
  • 12 months

    amikon warranty
  • 2-hour reply

    from your account manager
  • Success Story

    solutions in action
PRODUCT DESCRIPTION

NIMP01 Multifunction Processor Termination Module

ABB Bailey NIMP01 is an INFI 90 multifunction-processor termination module that brings the processor serial interfaces to the field connection arrangement. It provides two isolated RS-232-C ports; one port can instead be configured as a non-isolated RS-485 interface. The board occupies one slot in an NTMU01 or NTMU02 termination mounting unit.

The manufacturer instruction specifies 24 V DC supply and 210 mA maximum current consumption. Eighteen configurable jumpers establish the serial-port and related connection arrangements, including J18 selection for the RS-485 port. Operation is specified from 0 to 70 C, and the module includes a 1.0 A, 250 V DC fuse identified in the replacement instructions.
ACTUAL APPLICATIONS

Application fields for NIMP01

These broad application fields reflect the documented function and technical characteristics of NIMP01.
  • 01 · CHEMICALS

    Inorganic Resources and Petrochemical Fields

    Inorganic chemical resources and petrochemical fieldsOrganic chemical fields and specialty chemistry
  • 02 · OIL & GAS

    Onshore Gas and Petroleum Refining

    Onshore natural gas and petroleum refiningOffshore petroleum and associated condensate fields
  • 03 · POWER GENERATION

    Conventional Electricity and Hydroelectric Power

    Conventional electricity resources and hydroelectric powerRenewable electricity fields and thermal energy

Technical specifications for NIMP01

  • Product Model
    NIMP01
  • Product Parameters
    Multifunction Processor Termination Module
  • In stock
    1 unit
  • Manufacturer
    ABB
  • Supply voltage
    24 V DC
  • Maximum current consumption
    210 mA
  • RS-232-C interfaces
    2 isolated serial ports
  • Alternative port arrangement
    1 RS-232-C plus 1 non-isolated RS-485
  • Control-station serial links
    1
  • Configurable jumpers
    18
  • Operating temperature
    0 to 70 C
  • Relative humidity
    5 to 90% +/-5%, noncondensing
  • Maximum altitude
    3 km
  • Field-supply fuse
    1.0 A / 250 V DC
  • TMU slot requirement
    1
  • RS-485 selection jumper
    J18 pins 1-2; use P7
  • RS-232 mode terminal connector
    P5
  • Serial device cable limit
    15 m for listed HCBL01 cable
  • Termination-module cable limit
    30 m for listed NKTM01 cable
View all additional

Alternative Names

NIMP01 Bailey INFI 90 Multifunction Processor Termination Module
SYSTEM & REPLACEMENT CHECK

Information needed before ordering

Three direct checks to secure your system integration and minimize ordering risks.

Information

System integration Replacement check Manuals & support
SYSTEM INTEGRATION

Integrate NIMP01 within Bailey INFI 90

Select the serial mode and handshake arrangement from the NIMP01 jumper tables. The two RS-232-C ports are isolated, but the alternate RS-485 port is not; this distinction must be retained when planning the connected equipment and signal reference.
Use the applicable NKTM01, NKTU02 or NKTU12 connection arrangement for the installed processor and termination configuration. For RS-485 selection, J18 pins 1 and 2 are linked and P7 is used in place of P5; the P5 terminal serial port is inactive in that mode.
Mount the board in its assigned termination-unit position, connect 24 V DC, common and chassis ground as shown, and observe the environment limits. Follow the documented cable limits for the selected cable and connected device, rather than applying one distance to all serial paths.

Features:

  • Supply voltage: 24 V DC
  • Maximum current consumption: 210 mA
  • Bailey INFI 90
Use NIMP01 only within the documented Bailey INFI 90 arrangement and applicable installation instructions.
INTERCHANGEABILITY

Replace NIMP01 within Bailey INFI 90

Record all eighteen jumper positions and identify the processor, serial mode and connected cables before removing NIMP01. The auxiliary NIMP02 needs NIMP01 to operate and is not a standalone substitute for the main termination module.
Turn off cabinet and field-device power as required by the manufacturer before rewiring. Preserve supply, common, chassis ground and each serial connection, and verify that the replacement fuse and jumper arrangement match the installation.
After installing the spare, verify the selected RS-232-C or RS-485 mode, handshake behavior and communication with each intended device. Do not use a generic processor-board configuration to overwrite the termination-module settings.

Features:

  • NIMP01 complete suffix
  • Termination-module cable limit: 30 m for listed NKTM01 cable
  • Serial-port jumpers and cable assignments retained
Use NIMP01 only within the documented Bailey INFI 90 arrangement and applicable installation instructions.
DOCUMENTATION STATUS

Browse the Manuals, Datasheets, Official Documents, Links

Important Notice: The linked files are Amikong-hosted reference documents. Match their product identity and scope to the supplied assembly, and consult the applicable manufacturer instructions before use. Accessories and additional documents are included only when expressly listed in the quotation.

Features:

  • Exact-model technical data for NIMP01
  • Document applicability checked against the complete identity
  • Directory links by subcategory and brand
Documentation for NIMP01 must match the installed product identity and supplied configuration.

Important notice

Manuals, software, firmware, cables, calibration data and accessories are included only when listed in the quotation. AMIKON is an independent supplier and is not affiliated with or authorised by the manufacturer.
This content has been produced using multiple sources. Takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
BUYER INFORMATION

Commercial terms without hidden steps

Your written quote confirms the product identity, price, availability, lead time, warranty and shipping terms before payment.
  • 01

    Shipping & delivery

    Dispatch
    Eligible stock: same / next day
    Carriers
    DHL, FedEx or UPS
    Ship from
    Xiamen, China
    Product size
    3.50 x 17.20 x 17.70 cm
    Net weight
    0.28 kg
  • 02

    Payment & customs

    Payment
    Bank transfer (T/T)
    Currencies
    USD · EUR · GBP · RMB
    Credit cards
    Not accepted
    HS reference
    8538900000
    Origin
    Switzerland
  • 03

    Warranty & returns

    Warranty
    12 months from AMIKON
    Inspection
    Label, condition and packing checks
    Returns
    Prior RMA authorisation required
    Compatibility
    Confirm before order
    OEM warranty
    Does not apply
Your written quote confirms the product identity, price, availability, lead time, warranty and shipping terms before payment.
  • Part checked

    Full suffix recorded
  • Condition checked

    Label and appearance
  • Packing checked

    Antistatic protection
  • Tracking supplied

    Established couriers
  • Sandy Lin

    Dedicated account manager · 15+ years
FREQUENTLY ASKED QUESTIONS

Questions buyers ask about NIMP01

Direct answers about identity, compatibility, stock, warranty, payment and shipping.
  • Are both serial ports of NIMP01 isolated?

    NIMP01 provides two isolated RS-232-C ports. When one port is configured as RS-485, that alternate RS-485 interface is non-isolated.
  • What changes when J18 selects RS-485 on NIMP01?

    For NIMP01, jumper J18 pins 1-2 and use connector P7; the terminal serial port P5 becomes inactive in that mode.
  • How much 24 V current is required by NIMP01?

    The Bailey instruction specifies a maximum of 210 mA at +24 V DC for NIMP01.
  • Can NIMP02 operate without NIMP01?

    No. The manufacturer states that NIMP02 requires NIMP01; it is an auxiliary termination module rather than a substitute for the primary unit.
  • Which fuse rating is listed for NIMP01?

    The replacement procedure for NIMP01 calls for a 1.0 A, 250 V DC fuse, with cabinet power off during the replacement.
  • Must jumper positions be copied when replacing NIMP01?

    Yes. Record and reproduce the application-specific settings of the eighteen configurable jumpers on NIMP01, including serial mode and handshake selections.
  • Which cable details help a distributor source NIMP01?

    Identify NIMP01, the connected processor, serial-mode requirement and installed cable designations. Quote any NKTM01 or NKTU cable separately when required.
  • What should an incoming NIMP01 spare be compared against?

    Compare the NIMP01 label, fuse, connector condition and required supplied scope with the purchase order; configure its jumpers for the installation before applying power.
READY TO VERIFY YOUR PART?

Get a NIMP01 quote with price, lead time and revision check.

Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, drives and servo motors, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: Amikon Limited sells new and surplus products and develops channels for purchasing such products. Amikon Limited is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because Amikon Limited is not an authorized distributor of this product, the Original Manufacturer's warranty does not apply. Amikon Limited is not an authorized distributor, dealer, or representative of the products displayed on this website. All product names, trademarks, brands, and logos used on this website are the property of their respective owners. The description, explanation, or sale of products with these names, trademarks, brands, and logos is for identification purposes only and is not intended to indicate any association with or authorization from any rights holder.
Product

Product Browsing History