CONTROL BOARD
Ethernet (2 ports):10/100 Mbps
Voltage: 24 V DC
Power Consumption: 5-7 W (typical)
I/O Handling:up to 64 I/O channels
R9 Input Spare Kit
Low Voltage (LV): 380–480V AC
Optional High Voltage (HV):500–690V AC
Short-Circuit Current Rating (I_SC): ≤100 kA
Inrush Current Limit: ≤150% × rated input current
Isolation: ≥2.5 kV
Dynamic braking fuses:690V AC, 100–800A
Ambient Temp Range: -15°C to +45°C
Storage Humidity: ≤95% non-condensing
SPAREPART KIT IGBT MODULE 900A
Voltage Class: 1200V
Continuous: 900A
Continuous: 900A
Switching Frequency: Optimized for ≤3–8 kHz
Conduction Losses: 1.8–2.5V
Isolation Voltage: ≥3000 V
Thermal Resistance:0.03–0.07 K/W
operating temperature: -40°C to +125°C
LV AC industrial single drive module
ACS880-04 drives
3AXD10000497831
LV AC industrial single drive module
IEC: Pn 500 kW, 715 A, 500 V
UL: Pld 600 Hp, 705 A, 460 V
Number of Phases:3-phase
Enclosure Type NEMA:Open Type
Operating Humidity (RHamb):5 ... 95
Sound dB (A):72 dB(A
Frequency (f): 47.5 ... 63 Hz
Frame Size: R11
Input Voltage (Uin):380 ... 500 V
LV AC machinery drive module
LV AC machinery drive module
IEC: Pn 3 kW, 8 A, 400 V
UL: Pld 5 Hp, 7.6 A, 480 V
(ACS880-M04-08A0-5)
Number of Phases:3-phase
Degree of Protection:IP20
Enclosure Type NEMA:Open Type
Altitude:1000 m
Operating Humidity (RHamb):5 ... 9
Power Factor:0.98
Sound dB (A):47 dB(A)
Inverter module
Output Power: 1.1 kW
Output Voltage: 380–480 V AC, 3-phase ±10%
Continuous current: 4.5 A (at 40°C)
Dynamic peak current: Up to 7.0 A
Input Voltage: 3-phase 380–480 V AC
Input Current (Typ.): 4.6 A @ 480 V AC
GATE DRIVER BOARD
3AXD50000049025
GATE DRIVER BOARD
BGDR-01C
MODEL: ACS880-04
4 X CONNECTORS
REPLACED PART# 3AUA0000074145
ADAPTER BOARD
Electrical Rating:24V DC (±10%)
Compatibility:ACS880-04
Communication Ports:RS485
Operation: 0°C to +55°C
Storage: -40°C to +85°C
PROGRAMMED MODULE
PROGRAMMED
ZINT-571
3AXD50000037997P
Key Function:DCS/SCADA
integrated safety relays
Voltage Supply:24V DC (±10%)
Operating Temp.:-25°C to +60°C
CONTROL UNIT
Input Voltage:24V DC (±15%)
Fieldbus: PROFIBUS DP, PROFINET
Digital I/O: ≥16 configurable
Analog I/O: 2x ±10V/4–20mA inputs
Safety I/O: Safe Torque Off
Compatible Drives:ABB ACS880 series
RPBA/PXG01 I/O Boards
Operating Environment:-15°C to +55°C
MEMORY UNIT KIT
MEMORY UNIT KIT
AINF6 3.42 +ZMU-03 SP
Signal Compatibility: 4–20 mA, 0–10 V, ±10 V
Resolution: 16-bit precision
Storage Capacity:2–32 GB
Analog Input Module (AINF6): 24 V DC (±10%)
Voltage Range:300–500 V AC
Main Interface Board
3AUA0000031096
ACS800 Main Board
frequency converter communication board
Auxiliary Power Input: 24 V DC (±10%)
Power Consumption: ≤5 W (typical)
Digital I/O:24 V DC
Analog Inputs: 0–10 V or 4–20 mA
Communication Board Kit
Remote Monitoring
Communication Board Kit
Input Voltage: 24 V DC (±20%)
Power Consumption: < 5 W
Ethernet Port:10/100 Mbps RJ45
Serial Port(s):RS-485 / RS-232
Compact alternating current drives
Output Power: 160 kW (215 HP) at 400 V AC.
Output Current: 302 A
Input: 380–480 V AC, 3-phase (±10%), 50/60 Hz.
Output: 0–480 V AC
Efficiency: ≥97% (typical at full load)
Control I/O: 5x analog inputs (2x 0–10 V / 0–20 mA)
Switching Frequency: 1–8 kHz
Control panel
Type: LCD or TFT color touchscreen
Operating Voltage: 24 VDC (±10%) or 110–230 VAC
Power Consumption: 10–20 W
Operating Temperature: -10°C to +55°C
Storage Temperature: -40°C to +70°C
Humidity: 5–95% (non-condensing)
Frequency Converter
Standard: -10°C to +40°C
Extended: -20°C to +50°C
Storage Temperature Range:-40°C to +70°C
Humidity:5% to 95% non-condensing
Current Rating:Approximately 28 A
liquid-cooled inverter module
Voltage Rating: 400–690 VAC ±10%
Input Current: 1,100 A (maximum)
Frequency Range: 0–1000 Hz
Operating Temperature:-20°C to +50°C
Storage Temperature: -40°C to +70°C.
Humidity: 5% to 95% (non-condensing)
AC drive
Output Current: 105 A
Integrated Filter: L500
Frame Size: R7
Cooling Method: Air cooling
Voltage:3-phase 380–480 V AC (±10%)
Frequency:47–63 Hz
Input Current:120 A
Motor Power Range:55–75 kW
Apparent Power (S1):89 kVA (at 480 V)
ACS880 AC Drive- 500V, 3PH, wall mount, regenerative
LV AC industrial wall-mounted regenerative single drive
Input Supply:3-phase 380–480V AC (±10%), 50/60 Hz
Output Power:5.5 kW (7.5 HP) @ 400V AC
Output Current:21 A continuous (40°C ambient)
Overload Capacity:110% for 60s, 150% for 2s
Output Frequency:0–500 Hz (motor-dependent)
Efficiency:>98% (at full load)
Power Factor:0.98 (min)
LV AC industrial wall-mounted single drive
3AUA0000090441
ACS880-01-096A-5
PN: 55 kW, IN: 96 A
LV AC industrial wall-mounted single drive
IEC: Pn 55 kW, 96 A, 500 V
UL: Pld 75 Hp, 96 A, 460 V
LV AC industrial wall-mounted single drive
ACS880-01-040A-5
3ABD00037851-D
Type Designation:ACS880-01-040A-5
LV AC industrial wall-mounted single drive
IEC: Pn 22 kW, 40 A (ACS880-01-040A-5)
PN: 22KW, IN: 40A
LV AC industrial wall-mounted single drive
ACS880-01-04A8-5
3AUA0000090430
LV AC industrial wall-mounted single drive
IEC: Pn 2.2 kW, 4.8 A, 500 V
UL: Pld 3 Hp, 4.8 A, 460 V
PN: 2.2 kW, IN: 4.8 A
(ACS880-01-04A8-5)
LV AC industrial wall-mounted single drive
ACS880-01-021A-5
3AUA0000090435
LV AC industrial wall-mounted single drive
IEC: Pn 11 kW, 21 A, 500 V
UL: Pld 15 Hp, 21 A, 460 V
PN: 11.0 kW, IN: 21 A
(ACS880-01-021A-5)
Copyright Notice © 2004-2024 amikong.com All rights reserved
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.