

























Kindly Reminder
Can't Find Your Required Components?
If your specific control system parts are not listed on our website, contact us immediately.
Our procurement specialists will source genuine new components tailored to your technical requirements.
All Amikon-supplied automation parts include:
12 Months Warranty
24h /7 online Service ( info@amikon.cn | +86 18020776786 )
Original new Factory Sealed
PowerFlex 753 AC Drive
Bulletin Number:PowerFlex 753 AC Drive
with Embedded I/O
Corrosive Gas Protection and Cooling Type:
Standard Protection, Forced Air
Voltage Class:400 VAC, 3 PH
Output Current:260 Amps, 132kW ND, 110kW HD
Enclosure Type:Open Type
Input Type:AC Input with Precharge, no DC Terminals
Frame Size:Frame 6
EMC Filtering Options:Filtered,
CM jumper installed (preferred)
Dynamic Braking:DB Transistor
PowerFlex 753 AC Drive
Bulletin Number:PowerFlex 753 AC Drive
with Embedded I/O
Corrosive Gas Protection and Cooling Type:
Standard Protection, Forced Air
Voltage Class:400 VAC, 3 PH
Output Current:260 Amps, 132kW ND, 110kW HD
Enclosure Type:Open Type
Input Type:AC Input with Precharge, no DC Terminals
Frame Size:Frame 6
EMC Filtering Options:Filtered,
CM jumper installed (preferred)
Dynamic Braking:DB Transistor
PowerFlex 753 AC Drive
Bulletin Number:PowerFlex 753 AC Drive
with Embedded I/O
Corrosive Gas Protection and Cooling Type:
Standard Protection, Forced Air
Voltage Class:400 VAC, 3 PH
Output Current:205 Amps, 110kW ND, 90kW HD
Enclosure Type:Open Type
Input Type:AC Input with Precharge, no DC Terminals
Frame Size:Frame 6
EMC Filtering Options:Filtered
CM jumper installed (preferred)
PowerFlex 753 AC Drive
Bulletin Number:PowerFlex 753 AC Drive
with Embedded I/O
Corrosive Gas Protection and Cooling Type
Standard Protection, Forced Air
Voltage Class:400 VAC, 3 PH
Output Current:205 Amps, 110kW ND, 90kW HD
Enclosure Type:Open Type
Input Type:AC Input with Precharge, no DC Terminals
Frame Size:Frame 6
EMC Filtering Options:Filtered
CM jumper installed (preferred)
PowerFlex 753 AC Drive
Bulletin Number:PowerFlex 753 AC Drive
with Embedded I/O
Corrosive Gas Protection and Cooling Type:
Standard Protection, Forced Air
Voltage Class:400 VAC, 3 PH
Output Current:170 Amps, 90kW ND, 75kW HD
Enclosure Type:Open Type
Input Type:AC Input with Precharge, no DC Terminals
Frame Size:Frame 6
EMC Filtering Options:Filtered
CM jumper installed (preferred)
PowerFlex 753 AC Drive
Bulletin Number:PowerFlex 753 AC Drive
with Embedded I/O
Corrosive Gas Protection and Cooling Type:
Standard Protection, Forced Air
Voltage Class:400 VAC, 3 PH
Output Current:170 Amps, 90kW ND, 75kW HD
Enclosure Type:Open Type
Input Type:AC Input with Precharge, no DC Terminals
Frame Size:Frame 6
EMC Filtering Options:Filtered
M jumper installed (preferred)
Dynamic Braking:DB Transistor
HIM Blank (No HIM)
PowerFlex 753 AC Drive
Bulletin Number:PowerFlex 753 AC Drive
with Embedded I/O
Corrosive Gas Protection and Cooling Type:
Standard Protection, Forced Air
Voltage Class:400 VAC, 3 PH
Output Current:140 Amps, 75kW ND, 55kW HD
Enclosure Type:Open Type
Input Type:AC Input with Precharge, no DC Terminals
Frame Size:Frame 6
EMC Filtering Options:Filtered
CM jumper installed (preferred)
Dynamic Braking:DB Transistor
PowerFlex 753 AC Drive
Bulletin Number:PowerFlex 753 AC Drive
with Embedded I/O
Corrosive Gas Protection and Cooling Type:
Standard Protection, Forced Air
Voltage Class:400 VAC, 3 PH
Output Current:140 Amps, 75kW ND, 55kW HD
Enclosure Type:Open Type
Input Type:AC Input with Precharge, no DC Terminals
Frame Size:Frame 6
EMC Filtering Options:Filtered
CM jumper installed (preferred)
Dynamic Braking:None
DC Output Module
Series:ControlLogix
Module Type:Electronic Fused DC Output Module
Outputs:16-Point Electronically Fused
Voltage:12-24 Volts DC
Operating Voltage Range:10-30 Volts DC
Backplane Current at 5 Volts:250 milliamps
ControlLogix Diagnostic DC Output Module
Series:ControlLogix
Module Type:Diagnostic DC Output Module
Outputs:16-Point Diagnostic
Voltage:24 Volts DC Source
Operating Voltage Range:19.2-30 Volts DC
Maximum Output Current Rating-Point:2 Amps at
Power Dissipation (Max):3.3 Watts at 60 Celsius
GuardLogix Controller
Series:ControlLogix
Module Type:GuardLogix Controller
I-O Memory:0.98 MB
User Memory:8 MB
Maximum I-O:128,000
Maximum Analog I-O:4,000
Maximum Digital I-O:128,000
PowerFlex 753 AC Drive
AC DRIVE
AIR COOLED
POWERFLEX 753
AC INPUT WITH PRECHARGE
IP54
NEMA TYPE 12
690 VAC / 932 VDC
200 KW / 268 HP
212 AMP
FILTERING
JUMPER INSTALLED
NO INTERNAL TRANSISTOR
PowerFlex 753 AC Drive
AC DRIVE
AIR COOLED
POWERFLEX 753
AC INPUT WITH PRECHARGE
IP54
NEMA TYPE 12
600 VAC / 810 VDC
185 KW / 250 HP
242 AMP
FILTERING
JUMPER REMOVED
NO INTERNAL TRANSISTOR
NO HIM
PowerFlex 753 AC Drive
Bulletin Number:PowerFlex 753 AC Drive
Corrosive Gas Protection and Cooling Type:
Standard Protection, Forced Air
Voltage Class:400 VAC, 3 PH
Output Current:456 Amps, 250kW ND, 200kW HD
Enclosure Type:Type 12 / IP54
Input Type:AC Input with Precharge, no DC Terminals
Frame Size:Frame 7
EMC Filtering Options:Filtered
CM jumper installed (preferred)
Dynamic Braking:DB Transistor
PowerFlex 753 AC Drive
Bulletin Number:PowerFlex 753 AC Drive
with Embedded I/O
Corrosive Gas Protection and Cooling Type:
Standard Protection, Forced Air
Voltage Class:400 VAC, 3 PH
Output Current:302 Amps, 160kW ND, 132kW HD
Enclosure Type:Type 12 / IP54
Input Type:AC Input with Precharge, no DC Terminals
Frame Size:Frame 7
EMC Filtering Options:Filtered
CM jumper installed (preferred)
Dynamic Braking:None
PowerFlex 753 AC Drive
Series:PowerFlex 753
Frames:6...8
Enclosure Type:AC Input w/ Precharge
no DC Terminals
Frames:2 2...7
Enclosure Type 2:IP54, NEMA/UL Type 12
Voltage:400V AC / 540V DC
Filtering:Yes
Default CM Cap Connection:Jumper Installed
PowerFlex 753 AC Drive
Bulletin Number:PowerFlex 753 AC Drive
with Embedded I/O
Corrosive Gas Protection and Cooling Type:
Standard Protection, Forced Air
Voltage Class:400 VAC, 3 PH
Output Current:260 Amps, 132kW ND, 110kW HD
Enclosure Type:Type 12 / IP54
Input Type:AC Input with Precharge, no DC Terminals
Frame Size:Frame 7
EMC Filtering Options:Filtered
CM jumper installed (preferred)
Dynamic Braking:DB Transistor
PowerFlex 753 AC Drive
Bulletin Number:PowerFlex 753 AC Drive
with Embedded I/O
Corrosive Gas Protection and Cooling Type
Standard Protection, Forced Air
Voltage Class:400 VAC, 3 PH
Output Current:8.7 Amps,
(Fr1 4kW ND, 2.2kW HD/Fr2 4kW ND, 4kW HD)
Enclosure Type:Open Type/Frame 1
Input Type:AC Input with DC Terminals
Frame Size:Frame 1
EMC Filtering Options:Filtered
CM jumper installed (preferred)
Dynamic Braking:DB Transistor
PowerFlex 753 AC Drive
Bulletin Number:PowerFlex 753 AC Drive
with Embedded I/O
Corrosive Gas Protection and Cooling Type
Standard Protection, Forced Air
Voltage Class:400 VAC, 3 PH
Output Current:8.7 Amps,
(Fr1 4kW ND, 2.2kW HD/Fr2 4kW ND, 4kW HD)
Enclosure Type:Open Type/Frame 1
Input Type:AC Input with DC Terminals
Frame Size:Frame 1
EMC Filtering Options:Filtered
CM jumper installed (preferred)
Dynamic Braking:DB Transistor
PowerFlex 753 AC Drive
Bulletin Number:PowerFlex 753 AC Drive,
with Embedded I/O
Corrosive Gas Protection and Cooling Type:
Standard Protection, Forced Air
Voltage Class:400 VAC, 3 PH
Output Current:15.4 Amps, 7.5kW ND, 5.5kW HD
Enclosure Type:Open Type/Frame 1
Input Type:AC Input with DC Terminals
Frame Size:Frame 1
EMC Filtering Options:Filtered
CM jumper installed (preferred)
Dynamic Braking:DB Transistor
PowerFlex 753 AC Drive
Bulletin Number:PowerFlex 753 AC Drive
with Embedded I/O
Corrosive Gas Protection and Cooling Type:
Standard Protection, Forced Air
Voltage Class:400 VAC, 3 PH
Output Current:15.4 Amps, 7.5kW ND, 5.5kW HD
Enclosure Type:Open Type/Frame 1
Input Type:AC Input with DC Terminals
Frame Size:Frame 1
EMC Filtering Options:Filtered
CM jumper installed (preferred)
Dynamic Braking:DB Transistor
HIM Blank (No HIM)
PowerFlex Air Cooled 753 AC Drive
AC DRIVE
AIR COOLED
POWERFLEX 753
AC INPUT WITH PRECHARGE
IP20
OPEN TYPE
400 VAC / 540 VDC
7.5 KW / 10 HP
15.4 AMP
FILTERING
JUMPER REMOVED
INTERNAL TRANSISTOR
NO HIM
PowerFlex Air Cooled 753 AC Drive
PowerFlex 753 AC Drive
with Embedded I/O
Air Cooled AC Input with DC Terminals
Open Type/Frame 1
400V AC, 3PH, 11.5A
5.5kW Normal Duty
4kW Heavy Duty
Frame 1, Filtered
CM Jumper Removed
DB Transistor, No HIM
PowerFlex Air Cooled 753 AC Drive
Voltage Class:600 AC Volts
Output Current:52 Amperes
Phase Count:Three
Frame Size:5
Enclosure Type:IP00 (IP20 NEMA)
EMC Filtering Options:Filtered, No CM Jumper
Input Type:AC Input with DC Terminals
Dynamic Breaking:DB Transistor
PowerFlex 753 AC Drive
Bulletin Number:PowerFlex 753 AC Drive
with Embedded I/O
Corrosive Gas Protection and Cooling Type:
Standard Protection, Forced Air
Voltage Class:480 VAC, 3 PH
Output Current:8 Amps,
(Fr1 5HP ND, 3HP HD/Fr2 5HP ND, 5HP HD)
Enclosure Type:Open Type
Input Type:AC Input with DC Terminals
Frame Size:Frame 2
EMC Filtering Options:Filtered,
CM jumper installed (preferred)
Dynamic Braking:DB Transistor

Copyright Notice © 2004-2024 amikong.com All rights reserved
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.