General Electric IC695NIU001-ADAD
General Electric IC695NIU001-ADAD
General Electric IC695NIU001-ADAD
General Electric IC695NIU001-ADAD
General Electric IC695NIU001-ADAD
General Electric IC695NIU001-ADAD
· Product image is representative; revision or series may vary. Contact us to request a specific version.
Ships by Thursday, October 1

IC695NIU001-ADAD

Ethernet Network Interface Unit

Shipping Information

  • For inventory products, we support same day shipping upon payment.
  • For urgent needs, we offer same-day shipping on most items for orders placed before 2:00 PM UTC+8 Simply mention your preferred next-day shipping when place the order, and your order will be prioritized to minimize downtime.
  • For indent items, typical turnaround is 1-3 weeks, depending on parts availability and scarcity.
Customs & Documentation
We prepare clear, order-specific documentation for every international shipment, including the commercial invoice, packing list and available product or compliance documents. Before dispatch, our logistics team confirms the consignee details, declared value, shipping terms and destination requirements with you. Tracking information is provided after shipment, helping your team prepare for import clearance with confidence.
Documents checked before dispatch · Shipment details confirmed · Global tracking provided
Payment
Payment is by bank wire only in RMB/CNY, GBP, EUR or USD. Amikon does not accept credit cards or provide credit terms. Cleared payment is required before shipment unless the written quotation expressly states otherwise.
Product Condition
Factory New These are new and current items that are procured directly from the manufacturer.
New In Sealed Package Parts are new. They have not been used and still have their original package seal intact.
New in Original Package These parts are new. The packages were not originally sealed by their original manufacturer.
Quantity
Mobile *
Country/Region *
E-mail *
Company
Content *
(gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Amikong please read our privacy policy.
  • 20+

    years in automation
  • ISO 9001

    certified quality system
  • 12 months

    amikon warranty
  • 2-hour reply

    from your account manager
  • Success Story

    solutions in action
PRODUCT DESCRIPTION

IC695NIU001-ADAD Ethernet Network Interface Unit

GE IC695NIU001-ADAD is a Ethernet Network Interface Unit for PACSystems RX3i network interfaces. According to the applicable product documentation, network is Ethernet Global Data, ethernet ports is Two switched ports, i/o support is RX3i and Series 90-30 I/O, and control mode is Remote I/O station. Confirm the complete article code and installed hardware revision before replacement.
ACTUAL APPLICATIONS

Application context for IC695NIU001-ADAD

Official manufacturer documentation supports these system uses when the complete PACSystems RX3i network interfaces configuration is verified.
  • 01 · WATER & WASTEWATER

    Remote station data communications

    Industrial Ethernet SystemsPLC and remote I/O nodesFiber or copper network uplinks
  • 02 · OIL & GAS

    Pipeline control network integration

    Process Communication SystemsCompressor and metering stationsControl-room network switches
  • 03 · AUTOMOTIVE

    Production cell controller networking

    Factory Communication SystemsRobot and PLC controllersHMI and supervisory network links

Technical specifications for IC695NIU001-ADAD

  • Product Model
    IC695NIU001-ADAD
  • Product Parameters
    Ethernet Network Interface Unit
  • In stock
    1 unit
  • Manufacturer
    General Electric
  • Network
    Ethernet Global Data
  • Ethernet Ports
    Two switched ports
  • I/O Support
    RX3i and Series 90-30 I/O
  • Control Mode
    Remote I/O station
  • Data Exchange
    Automatic configured exchange
  • Controller Status
    Returned with each exchange
  • Backplane
    RX3i Universal Backplane
  • Configuration
    PAC Machine Edition
  • Diagnostics
    Local and network status LEDs
View all additional

Alternative Names

IC695NIU001 ADAD PACSystems RX3i network interfaces Ethernet network interface unit GE Ethernet network interface unit
SYSTEM & REPLACEMENT CHECK

Information needed before ordering

Three direct checks to secure your system integration and minimize ordering risks.

Information

System integration Replacement check Manuals & support
SYSTEM INTEGRATION

Match IC695NIU001-ADAD to the installed PACSystems RX3i network interfaces

GE IC695NIU001-ADAD is a Ethernet network interface unit for the PACSystems RX3i network interfaces. Its exact article suffix determines the supported interface, signal or communication function and the approved companion equipment.
Engineering should compare control mode (Remote I/O station), data exchange (Automatic configured exchange) and controller status (Returned with each exchange) with the installed system design. Confirm connector keying, addressing and configuration-tool support before connection.
Use the manufacturer documentation for the complete wiring and configuration sequence. Validate communication, signal conversion or control response with the connected equipment, then archive measured results and the final configuration with the asset record.

Features:

  • Exact identity: IC695NIU001-ADAD
  • Product class: Ethernet network interface unit
  • Family: PACSystems RX3i network interfaces
The GE IC695NIU001-ADAD requires documented system integration before energising the equipment.
REPLACEMENT CONTROL

Verify the complete IC695NIU001-ADAD identity before exchange

Replace IC695NIU001-ADAD only after matching the complete article code, Ethernet network interface unit, installed PACSystems RX3i network interfaces role and documented hardware or firmware revision. Similar housings and related family numbers do not establish functional interchangeability.
Photograph the nameplate, keyed connectors, terminal numbering, cable routing, shields, earth points and adjacent modules. Export the applicable controller, HMI, drive or network configuration and record addresses, parameters and diagnostic messages before removal.
After fitting the verified article, restore the controlled configuration and check every affected signal or communication path. Review status indications and diagnostic buffers, run the documented functional test at a safe operating point and retain the final acceptance record.

Features:

  • Exact identity: IC695NIU001-ADAD
  • Product class: Ethernet network interface unit
  • Family check: PACSystems RX3i network interfaces
The GE IC695NIU001-ADAD requires documented replacement verification before energising the equipment.
DOCUMENTATION STATUS

Browse the Manuals, Datasheets, Official Documents, Links

Important Notice: Official documents are provided through manufacturer links. Accessories, manuals, cables, calibration data, software and certificates are included only when listed in the quotation.

Features:

  • Technical values prepared for IC695NIU001-ADAD
  • GE PACSystems RX3i network interfaces references reviewed
  • Exact GE identity required before service
Documentation for GE IC695NIU001-ADAD must match the installed equipment; confirm document applicability before service.

Important notice

Manuals, software, firmware, cables, calibration data and accessories are included only when listed in the quotation. AMIKON is an independent supplier and is not affiliated with or authorised by the manufacturer.
This content has been produced using multiple sources. Takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
BUYER INFORMATION

Commercial terms without hidden steps

Your written quote confirms the product identity, price, availability, lead time, warranty and shipping terms before payment.
  • 01

    Shipping & delivery

    Dispatch
    Eligible stock: same / next day
    Carriers
    DHL, FedEx or UPS
    Ship from
    Xiamen, China
    Packed size
    25 × 20 × 15 cm
    Shipping weight
    1.20 kg
  • 02

    Payment & customs

    Payment
    Bank transfer (T/T)
    Currencies
    USD · EUR · GBP · RMB
    Credit cards
    Not accepted
    HS reference
    85389091
    Origin
    United States
  • 03

    Warranty & returns

    Warranty
    12 months from AMIKON
    Inspection
    Label, condition and packing checks
    Returns
    Prior RMA authorisation required
    Compatibility
    Confirm before order
    OEM warranty
    Does not apply
Your written quote confirms the product identity, price, availability, lead time, warranty and shipping terms before payment.
  • Part checked

    Full suffix recorded
  • Condition checked

    Label and appearance
  • Packing checked

    Antistatic protection
  • Tracking supplied

    Established couriers
  • Sandy Lin

    Dedicated account manager · 15+ years
FREQUENTLY ASKED QUESTIONS

Questions buyers ask about IC695NIU001-ADAD

Direct answers about identity, compatibility, stock, warranty, payment and shipping.
  • Receiving IC695NIU001-ADAD for maintenance service: check Ethernet Global Data network?

    For IC695NIU001-ADAD during preventive maintenance, a maintenance planner should match network (Ethernet Global Data) and ethernet ports (Two switched ports) to the installed PACSystems RX3i network interfaces design. A mismatch can prevent correct integration even when the hardware appears similar.
  • Maintenance service: does IC695NIU001-ADAD match Two switched ports?

    For preventive maintenance, identify IC695NIU001-ADAD by the combined specification: ethernet ports is Two switched ports, while i/o support is RX3i and Series 90-30 I/O. A maintenance planner should confirm both values rather than relying on the family name or enclosure.
  • Confirming IC695NIU001-ADAD i/o support during maintenance service?

    Before wiring or mounting IC695NIU001-ADAD, a maintenance planner should verify the installation supports i/o support of RX3i and Series 90-30 I/O and preserves the documented control mode of Remote I/O station. Record this check in the preventive maintenance work pack.
  • IC695NIU001-ADAD control mode: Remote I/O station or another value — maintenance service?

    During preventive maintenance, a maintenance planner should commission IC695NIU001-ADAD under a controlled load or signal and confirm control mode reaches Remote I/O station. Cross-check data exchange against Automatic configured exchange, then save the measured result for engineering acceptance.
  • IC695NIU001-ADAD selection check for maintenance service: data exchange?

    During preventive maintenance, a maintenance planner should isolate the circuit, compare the actual data exchange with the IC695NIU001-ADAD specification of Automatic configured exchange, and inspect the related controller status requirement (Returned with each exchange). This separates a module fault from a supply, wiring, or configuration issue.
  • Maintenance service evidence for IC695NIU001-ADAD: controller status?

    For preventive maintenance, the IC695NIU001-ADAD service record should state controller status as Returned with each exchange and retain backplane at RX3i Universal Backplane. These values give a maintenance planner a repeatable baseline for later replacement and fault diagnosis.
  • IC695NIU001-ADAD backplane for distributor maintenance service?

    For a maintenance planner's preventive maintenance request, the quotation should identify the complete IC695NIU001-ADAD code and confirm backplane (RX3i Universal Backplane) together with configuration (PAC Machine Edition). The distributor should flag any revision or substitute that changes either requirement.
  • IC695NIU001-ADAD at PAC Machine Edition: MRO maintenance service concern?

    For a maintenance planner's preventive maintenance requirement, check the delivered IC695NIU001-ADAD label and order code, then verify configuration is PAC Machine Edition and network is Ethernet Global Data. Photograph the label and connectors before acceptance so purchasing and maintenance share the same identity record.
READY TO VERIFY YOUR PART?

Get a IC695NIU001-ADAD quote with price, lead time and revision check.

Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, drives and servo motors, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: Amikon Limited sells new and surplus products and develops channels for purchasing such products. Amikon Limited is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because Amikon Limited is not an authorized distributor of this product, the Original Manufacturer's warranty does not apply. Amikon Limited is not an authorized distributor, dealer, or representative of the products displayed on this website. All product names, trademarks, brands, and logos used on this website are the property of their respective owners. The description, explanation, or sale of products with these names, trademarks, brands, and logos is for identification purposes only and is not intended to indicate any association with or authorization from any rights holder.