Close Menu
Get Parts Quote
Name
Company *
WhatsApp / WeChat (For Faster Quote) *
Email *
Address
City
State / Province / Region
Zipcode
Country
Quantity *
Part Number *
Manufacturer
Preferred Condition
Additional Information
Cancel
2026-09-28 16:07:52
9 min read

Honeywell 10024/H/I: RS-422/485 Configuration & Spare-Parts Guide

About the Reviewer
Sandy Lin
Sandy Lin's linkedin:

Sandy Lin - Amikon Gorden Partner
With 15+ year experience in automation parts supply, Sandy has served over 8,000 clients, achieving an 85% satisfaction rate. The supplied products are applied in government departments, involving various fields such as petrochemicals, metallurgy, steel, wind power, hydropower, aviation, packaging and transportation, etc. Her professional services and rapid response have earned it a highly praised reputation in the automation industry.She can perceive market changes, provide timely solutions to customers, and achieve sustainable long-term cooperation.
FSC technical guide · enhanced communication module

Honeywell 10024/H/I · RS‑422/485 Communication Guide

Interface configuration, cable limits and spare-parts checks for installed Honeywell FSC systems.

A
H INTERFACERS‑422 with readbackUp to 2 Mbaud
B
I INTERFACEIsolated RS‑485 / RS‑422Up to 1 Mbaud · >6 kV isolation
Verify the complete suffix, interface position and configured application before replacement.

What the 10024/H/I actually does

The 10024/H/I is not a generic serial converter. It is a model-specific Enhanced Communication Module (ECM) for the Honeywell Fail Safe Control (FSC) platform.

The ECM family offloads communication work from the FSC central processor through its own processor and memory. Depending on the loaded application and the engineered system, the family supports functions such as FSC-to-FSC communication, connections with DCS equipment and peripherals, sequence-of-events recording, report generation and supported serial protocols.

The suffixes define the physical interfaces. On the 10024/H/I, the upper A channel is the H interface—RS‑422 with readback—while the lower B channel is the I interface, an isolated RS‑485/RS‑422 port. That distinction is the first thing to verify during replacement because visually similar 10024 variants can use RS‑232C or fiber interfaces instead.

Type10024/H/I
Model ID26900
Rack space8 HP · 3U
Supply5 Vdc · 675 mA

H and I are different electrical paths

Use the selector to compare the two channels. The values below describe the physical-interface limits documented for the module; the protocol, baud rate and addressing must still match the installed FSC application.

RS‑422 with readback

The H interface is designed for the dedicated RS‑422 path used by the engineered FSC communication arrangement. It is rated up to 2 Mbaud and uses a male 9-pin connector.

Physical layerRS‑422
Maximum baud2 Mbaud
ConnectorMale · 9 pin

Isolated RS‑485 / RS‑422

The I interface provides galvanic isolation greater than 6 kV and supports the longer multidrop or point-to-point serial path defined by the FSC design.

Physical layerRS‑485 / RS‑422
Maximum baud1 Mbaud
Isolation> 6 kV

Cable length falls as baud rate rises

For the isolated I interface, the published limits assume suitable cable and correct termination. Treat them as design ceilings, not a substitute for checking the installed drawing, cable type, shielding, grounding and topology.

100 kbaud
 
1.2 km
125 kbaud
 
1.0 km
1 Mbaud
 
120 m
2 Mbaud
 
60 m
Do not hot-swap this module.

Honeywell’s hardware documentation states that the module must not be removed or replaced while power is applied to its Central Part. Plan the isolation, backup and controlled restart before physical work begins.

Same-series reference

Honeywell FSC series: hardware context

Context note: This video shows a related product from the Honeywell FSC series, not the 10024/H/I. Use it to understand the wider hardware family only; verify the 10024/H/I label, H/I interface positions, model ID and installed configuration from the article before procurement.

Configuration lives beyond the part number

A correct label is necessary, but it does not prove that a spare can be inserted without preparation. The 10024 main board can use flash memory or EPROMs, and its jumpers define module numbering and program source. The system-bus arrangement also matters: a Central Part system-bus jumper is removed when a new communication module is installed.

01
Full type codeConfirm 10024/H/I and model ID 26900.
02
Interface positionsH on channel A; isolated I on channel B.
03
Software baselineRecord application, protocol and FSC configuration.
04
Memory mediaIdentify flash/EPROM fit and programmed contents.
05
JumpersPhotograph J1–J5 and system-bus jumper state.
06
Field connectionVerify pinout, cable, termination and grounding.

Pass four purchase gates

A spare should move to approval only after all four gates are documented in the quotation and supporting evidence.

01
Identity gate

Exact hardware

10024/H/I, model ID 26900, with H above I.

02
Evidence gate

Visible configuration

Label, revision, flash/EPROM and jumper photos.

03
Quality gate

Defined condition

Condition, serial-linked test scope and warranty.

04
Execution gate

Complete changeover

Accessories, power-down plan and functional test.

Approval ruleIf one gate is unclear, pause the order and request written clarification.

10024/H/I FAQs

Can the 10024/H/I replace a 10024/I/I?

Not as a direct like-for-like substitution. The H/I model has one H interface and one isolated I interface; the I/I model has two isolated I interfaces. Confirm the engineered channel functions and wiring before considering any change.

Does the I interface support both RS‑422 and RS‑485?

Yes. Honeywell identifies the I interface as an isolated RS‑485/RS‑422 interface. Its actual operating mode, protocol, baud rate and topology depend on the installed configuration.

Is 1.2 km always acceptable at 100 kbaud?

No. It is a documented maximum under the specified interface conditions. Cable type, termination, shielding, grounding, noise and network topology still need engineering verification.

What information should be sent with an inquiry?

Send photos of the front and side labels, module ID, revision details, flash/EPROM arrangement, jumper positions, required quantity and the planned shutdown date. Include the installed FSC configuration when available.

Keep your system in play!

Select
ABB
Accutrac
Acopian
AC Tech
Action Instruments
Adam
Adaptec
Advanced Micro Controls
AEG
Alcatel
Allen-Bradley
3M
Alstom
AMCI
Apparatebau Hundsbach
Array Electronic
ASTEC
Automation Direct
B&R
Balluff
Banner Engineering
Barco Sedo
Bartec
BECK
Beier
Beijer Electronics
Bently Nevada
Biviator
Black Box
Bosch
Braun
CEAG
Crouzet
Control Techniques
CTI-Control Technology Inc
Cutler-Hammer
Danfoss
DEC - Digital Equipment Corp
Delta Computer Systems
Delta Electronics
Digital
Digitronics
Durag
EATON
EBELT
Eberle
Emerson
Endress Hauser
Entrelec Schiele
Eurotherm
Fanuc
Farnell
Festo
Finder Varitec
Fischer Porter
Forney Engineering
Fuji Electric
General Electric
Grayhill
Harting
Hedin Tex
HEIDENHAIN
Helmholz
HIMA
Hirschmann
Hitachi
Honeywell
IBM
idec
IDS
IFM Electronic
INAT
Intel
Invensys
JAQUET
Jetter AG
Kieback & Peter
Klockner Moeller
Koyo
Kuhnke
Lambda
Landis Gyr
Lauer
L&N - Leeds & Northrup
Lenze
Leukhardt Systems
LG GoldSec
Littlefuse
Lumberg
Magnecraft
Mannesmann
Matsushita
Mean Well
Measurement Systems
Measurex
MEDAR
Micro Innovation AG
Micron Control Transformers
Mitsubishi
Molex
Moog
MTL Insturments Group
MTS
Murr Elektronik
NAIS
NEC
Omega Engineering
Omron
Opto 22
Orbitran Systems
PANALARM
Pepperl + Fuchs
Philips
Phoenix Contact
Pilz
Red Lion
Reliance Electric
Rexroth
RIS - Rochester
Ronan
SAE Elektronik
SAIA
Sauter
Schiele
Schildknecht
Schiller Electric
Schleicher
Schneider Electric
Schrack Technik
Selectron
SEW
Spectrum Controls
Sprecher + Schuh
Square D
Stahl
STI - Scientific Technologies, Inc.
SysMik
Taylor
Tecnint HTE
Telemecanique
Toshiba
Transition Networks
TR Electronic
UniOP
Vibro-Meter
VIPA
Visolux
Wachendorff Advantech
Wago
Weidmuller
Wöhrle
Woodward
Yokogawa
Ziehl-Abegg
Xycom
Epro
bachmann
Saftronics
Siemens
KEB
Opti Mate
Arista
MKS
Motortronics
Metso Auttomation
ProSoft
Nikki Denso
K-TEK
Motorola VME
Force Computers Inc
Berger Lahr
ICS Triplex
Sharp PLC
YASKAWA
SCA Schucker
Bremer
Molex Woodhead
Alfa Laval
Siemens Robicon
Proface
Supcon
Carlo Gavazzi
SST
Hollysys
SOLIDSTATE CONTROLS
ETEK
OPTEK
KUKA
WHEDCO
indramat
Miscellaneous Manufacturers
TEKTRONIX
Rorze
DEIF
SIPOS
SHINKAWA
ANYBUS
HVA
GERMAN POWER
KONTRON
ENTEK
TEL
SYSTEM
KOLLMORGEN
LAZER
PRECISION DIGITAL
LUBRIQUIPINC
NOKIA
SIEI-Gefran
MSA AUER MUT
KEBA
ANRITSU
DALSA
Load Sharer
SICK
Brad
SCHENCK
STAIGER MOHILO
ENTERASYS
USB-LG
TRS
BIOQUELL
SCHMERSAL
CORECO
KEYENCE
BIZERBA
BAUERBAUER
CONTROL
PACIFIC SCIENTIFIC
APPLIED MATERIALS
NMB
NI
Weishaupt
Weinview
CISCO
PARKER
KONECRANES
TURBUL
HMS
HOFFMAN
HUTTINGER
TDK-Lambda
RESOLVER
Knick
ATLAS
BENDER
SABO
BALDOR
Lam Research
NTN BEARING
ETA
WEST INSTRUMENTS
TDK-Lambda
Fireye
DAHUA
TESCH
ACROSSER
FLUKE
Sanyo Denki
Bruel & Kjaer
EPSON
HIOKI
Mettler Toledo
RAYTEK
EPCOS
DFI
SEMIKRON
Huawei
INDUSTRONIC
ASI-HVE
BARTEC POLARIS
AMAT
GD Bologna
Precise Automation
RADISYS
ZEISS 
Reveal Imaging
Saiernico
ASEM
Advantech
ANSALDO
ELpro
MARCONI
EBMPAPST
ROTORK
KONGSBERG
SOCAPEL
TAIYO
SUN
York
KURODA
ADLINK
Notifier
HBM
Infineon
LNIC
Saipwell
JIANGYIN ZHONGHE
W.E.ST. Elektronik
EXPO
DEEP SEA ELECTRONICS
BECKHOFF
Drager
ZENTRO ELEKTRONIK
ATOS
TRSystemtechnik
JDS Uniphase
ADEPT
REO
Panametrics
Xenus
SIGMATEK DIAS
S.C.E Elettronica
EKF
ETEL
STOBER POSIDYN
HANSHIN
DDK
EITZENBERGER
LTI MOTION
XP Power
Panasonic
Matrox
SBS Technologies
WARTSILA
MURPHY
MADOKA
Arcnet Danpex
Littelfuse
TACAN
Hurco
SAMGONG
ALPHA
Luxco
Nautibus
PAWO Systems
Haver&boecker
VAISALA
Consilium
SERIPLEX
MTU
ALPHI
OPTIMATION INC
NTRON
TMEIC GLOBAL
BAUMER
SANYO-DENKI
Seica
ISE Reiter
Seal
ICP ELECTRONICS
Axiomtek
Bautz
Sonosys
Vacon
Nematron
Watt Drive
Sieb & Meyer
Danaher Motion
DEMAG
Digifas
Divus
Bühler
RMV ELECTRONICS
Ono Sokki
Orbotech
PLATING ELECTRONIC
NORD NORDAC
Circuit Line
Berges
AIENSN
SZM
CHATILLON
ACS GROUP
ADVANTEST
Sekidenko
DOLD
TURCK
API Controls
ASAHI KEIKI
QUALIFLOW
ASML
ASTRO
COGNEX
Contec
ESTIC
Fishman
IAI
TeleFrank
Internix
AUMA
PROVIBTECH
K-TRON
Lemforder
IXYS
ALERTON
MOXA
SCIYON
BASLER ELECTRIC
IntraAction
VAT
Delta tau
EMG
HENGSTLER
WESTERMO
Deutsmann Automation
CUMMINS
Bihl+Wiedemann
DAIKIN
Joppich
POUNDFUL
LEINE LINDE
DELIXI
Compressor Controls Corporation
JENAER ANTRIEBSTECHNIK
MCGS
SMC
Load Cell Central
KFG LEVEL
Peripheral Control Systems Corporation
SanDisk
CHINT
Selinc
Eltek
AI‑Tek
HACH
POWER ONE
SIMTRONICS
Get Parts Quote
Comments

Leave Your Comment

Company
* Email
* Mobile
* Content
Your email address will not be published
Newsroom

Related articles Browse All

  • Implementing Vision Systems for Industrial Robots: Enhancing Precision and Automation
    Blog
    2025-08-12 11:26:54
    Implementing Vision Systems for Industrial Robots: Enhancing Precision and Automation
    Industrial robots gain powerful new abilities through vision systems. These systems give robots the sense of sight, so they can understand and react to what is around them. So, robots can perform complex tasks with greater accuracy and flexibility. Automation in manufacturing reaches a new level of ...
  • Optimizing PM Schedules Data-Driven  Approaches to Preventative Maintenance
    Blog
    2025-08-21 18:08:33
    Optimizing PM Schedules Data-Driven Approaches to Preventative Maintenance
    Moving away from fixed maintenance schedules is a significant operational shift. Companies now use data to guide their maintenance efforts. This change leads to greater efficiency and equipment reliability. The goal is to perform the right task at the right time, based on real information, not just ...
  • The Evolution of Steam Turbine Control Systems
    Blog
    2026-03-31 08:33:35
    The Evolution of Steam Turbine Control Systems
    CALL US:+86-18020776786 | E-MAIL:INFO@AMIKON.CN In-depth analysis of the GE Mark VIe control system Mark VIe: A Modern Mainstay for Industry 4.0 Mark VIe's core concepts are "high availability, open connectivity, and intelligent readiness." It utilizes comm...