Close Menu
Get Parts Quote
Name
Company *
WhatsApp / WeChat (For Faster Quote) *
Email *
Address
City
State / Province / Region
Zipcode
Country
Quantity *
Part Number *
Manufacturer
Preferred Condition
Additional Information
Cancel
In Stock
Fast Shipping Available
Metso Auttomation IOP301
· Product image is representative; revision or series may vary. Contact us to request a specific version.
Ships by Tuesday, September 29

IOP301

isolated analog input module

Shipping Information

  • For inventory products, we support same day shipping upon payment.
  • For urgent needs, we offer same-day shipping on most items for orders placed before 2:00 PM UTC+8 Simply mention your preferred next-day shipping when place the order, and your order will be prioritized to minimize downtime.
  • For indent items, typical turnaround is 1-3 weeks, depending on parts availability and scarcity.
Customs & Documentation
We prepare clear, order-specific documentation for every international shipment, including the commercial invoice, packing list and available product or compliance documents. Before dispatch, our logistics team confirms the consignee details, declared value, shipping terms and destination requirements with you. Tracking information is provided after shipment, helping your team prepare for import clearance with confidence.
Documents checked before dispatch · Shipment details confirmed · Global tracking provided
Payment
Payment is by bank wire only in RMB/CNY, GBP, EUR or USD. Amikon does not accept credit cards or provide credit terms. Cleared payment is required before shipment unless the written quotation expressly states otherwise.
Product Condition
Factory New These are new and current items that are procured directly from the manufacturer.
New In Sealed Package Parts are new. They have not been used and still have their original package seal intact.
New in Original Package These parts are new. The packages were not originally sealed by their original manufacturer.
Quantity
Mobile *
Country/Region *
E-mail *
Company
Content *
(gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Amikong please read our privacy policy.
  • 20+

    years in automation
  • ISO 9001

    certified quality system
  • 12 months

    amikon warranty
  • 2-hour reply

    from your account manager
  • Success Story

    solutions in action
PRODUCT DESCRIPTION

IOP301 isolated analog input module

Metso Auttomation IOP301 is a isolated analog input module documented for maxPAC I/O. It performs its assigned input, processing, operator-interface, control or cooling function through the manufacturer-specified electrical and mechanical interfaces. Verify the complete article identity and installed system configuration before replacement or commissioning.
ACTUAL APPLICATIONS

Application context for IOP301

Official manufacturer documentation supports these system uses when the complete maxPAC I/O configuration is verified.
  • 01 · OIL & GAS

    Process signal acquisition cabinets

    Distributed I/O SystemsIsolated transmitter inputRedundant transmitter wiring
  • 02 · POWER GENERATION

    Turbine auxiliary control panels

    Process I/O SystemsAnalog process measurementCondition signal acquisition
  • 03 · CHEMICAL PROCESSING

    Reactor instrumentation cabinets

    Plant Control Systems4-20 mA transmitter inputVoltage signal conversion

Technical specifications for IOP301

  • Product Model
    IOP301
  • Product Parameters
    isolated analog input module
  • In stock
    1 unit
  • Manufacturer
    Metso Auttomation
  • Input Channels
    16 isolated channels
  • Input Configuration
    Voltage or current, mixed by channel
  • Current Span
    4 to 20 mA
  • Voltage Span
    0 to 2.4 V
  • Resolution
    15 bits plus sign
  • Scan Rate
    100 ms
  • RTI Accuracy
    ±0.1% full scale at 25 °C
  • Temperature Sensitivity
    ±0.004% of reading/°C and ±1.5 µV/°C
  • Conversion Method
    Sigma-delta oversampling
  • Current Input Impedance
    300 Ω
  • Voltage Input Impedance
    1 MΩ
  • Normal Mode Rejection
    60 dB at 50/60 Hz
  • Common Mode Rejection
    120 dB at 50/60 Hz
  • Isolation
    1500 V AC field-to-logic; 500 V AC channel-to-channel
  • System Supply Load
    400 mA from 24 V supply
View all additional

Alternative Names

IOP301 maxPAC I/O isolated analog input module Metso Auttomation isolated analog input module
SYSTEM & REPLACEMENT CHECK

Information needed before ordering

Three direct checks to secure your system integration and minimize ordering risks.

Information

System integration Replacement check Manuals & support
SYSTEM INTEGRATION

Match IOP301 to the installed maxPAC I/O

Metso Auttomation IOP301 is a isolated analog input module for the maxPAC I/O. Its exact article suffix determines the supported interface, signal or communication function and the approved companion equipment.
Engineering should compare voltage span (0 to 2.4 V), resolution (15 bits plus sign) and scan rate (100 ms) with the installed system design. Confirm connector keying, addressing and configuration-tool support before connection.
Use the manufacturer documentation for the complete wiring and configuration sequence. Validate communication, signal conversion or control response with the connected equipment, then archive measured results and the final configuration with the asset record.

Features:

  • Exact identity: IOP301
  • Product class: isolated analog input module
  • Family: maxPAC I/O
The Metso Auttomation IOP301 requires documented system integration before energising the equipment.
REPLACEMENT CONTROL

Verify the complete IOP301 identity before exchange

Replace IOP301 only after matching the complete article code, isolated analog input module, installed maxPAC I/O role and documented hardware or firmware revision. Similar housings and related family numbers do not establish functional interchangeability.
Photograph the nameplate, keyed connectors, terminal numbering, cable routing, shields, earth points and adjacent modules. Export the applicable controller, HMI, drive or network configuration and record addresses, parameters and diagnostic messages before removal.
After fitting the verified article, restore the controlled configuration and check every affected signal or communication path. Review status indications and diagnostic buffers, run the documented functional test at a safe operating point and retain the final acceptance record.

Features:

  • Exact identity: IOP301
  • Product class: isolated analog input module
  • Family check: maxPAC I/O
The Metso Auttomation IOP301 requires documented replacement verification before energising the equipment.
DOCUMENTATION STATUS

Browse the Manuals, Datasheets, Official Documents, Links

Important Notice: Official documents are provided through manufacturer links. Accessories, manuals, cables, calibration data, software and certificates are included only when listed in the quotation.

Features:

  • Technical values prepared for IOP301
  • Metso Auttomation maxPAC I/O references reviewed
  • Exact Metso Auttomation identity required before service
Documentation for Metso Auttomation IOP301 must match the installed equipment; confirm document applicability before service.

Also searched as

Important notice

Manuals, software, firmware, cables, calibration data and accessories are included only when listed in the quotation. AMIKON is an independent supplier and is not affiliated with or authorised by the manufacturer.
This content has been produced using multiple sources. Takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
BUYER INFORMATION

Commercial terms without hidden steps

Your written quote confirms the product identity, price, availability, lead time, warranty and shipping terms before payment.
  • 01

    Shipping & delivery

    Dispatch
    Eligible stock: same / next day
    Carriers
    DHL, FedEx or UPS
    Ship from
    Xiamen, China
    Packed size
    9.8 × 20.2 × 19.5 cm
    Shipping weight
    0.38 kg
  • 02

    Payment & customs

    Payment
    Bank transfer (T/T)
    Currencies
    USD · EUR · GBP · RMB
    Credit cards
    Not accepted
    HS reference
    8537101190
    Origin
    United States
  • 03

    Warranty & returns

    Warranty
    12 months from AMIKON
    Inspection
    Label, condition and packing checks
    Returns
    Prior RMA authorisation required
    Compatibility
    Confirm before order
    OEM warranty
    Does not apply
Your written quote confirms the product identity, price, availability, lead time, warranty and shipping terms before payment.
  • Part checked

    Full suffix recorded
  • Condition checked

    Label and appearance
  • Packing checked

    Antistatic protection
  • Tracking supplied

    Established couriers
  • Sandy Lin

    Dedicated account manager · 15+ years
FREQUENTLY ASKED QUESTIONS

Questions buyers ask about IOP301

Direct answers about identity, compatibility, stock, warranty, payment and shipping.
  • Controls retrofit: does IOP301 match 16 isolated channels?

    For IOP301 during retrofit planning, a controls engineer should match input channels (16 isolated channels) and input configuration (Voltage or current, mixed by channel) to the installed maxPAC I/O design. A mismatch can prevent correct integration even when the hardware appears similar.
  • Confirming IOP301 input configuration during controls retrofit?

    For retrofit planning, identify IOP301 by the combined specification: input configuration is Voltage or current, mixed by channel, while current span is 4 to 20 mA. A controls engineer should confirm both values rather than relying on the family name or enclosure.
  • IOP301 current span: 4 to 20 mA or another value — controls retrofit?

    Before wiring or mounting IOP301, a controls engineer should verify the installation supports current span of 4 to 20 mA and preserves the documented voltage span of 0 to 2.4 V. Record this check in the retrofit planning work pack.
  • IOP301 selection check for controls retrofit: voltage span?

    During retrofit planning, a controls engineer should commission IOP301 under a controlled load or signal and confirm voltage span reaches 0 to 2.4 V. Cross-check resolution against 15 bits plus sign, then save the measured result for engineering acceptance.
  • Controls retrofit evidence for IOP301: resolution?

    During retrofit planning, a controls engineer should isolate the circuit, compare the actual resolution with the IOP301 specification of 15 bits plus sign, and inspect the related scan rate requirement (100 ms). This separates a module fault from a supply, wiring, or configuration issue.
  • IOP301 scan rate for controls retrofit?

    For retrofit planning, the IOP301 service record should state scan rate as 100 ms and retain rti accuracy at ±0.1% full scale at 25 °C. These values give a controls engineer a repeatable baseline for later replacement and fault diagnosis.
  • IOP301 at ±0.1% full scale at: distributor controls retrofit concern?

    For a controls engineer's retrofit planning request, the quotation should identify the complete IOP301 code and confirm rti accuracy (±0.1% full scale at 25 °C) together with temperature sensitivity (±0.004% of reading/°C and ±1.5 µV/°C). The distributor should flag any revision or substitute that changes either requirement.
  • How MRO controls retrofit teams check IOP301 temperature sensitivity?

    For a controls engineer's retrofit planning requirement, check the delivered IOP301 label and order code, then verify temperature sensitivity is ±0.004% of reading/°C and ±1.5 µV/°C and input channels is 16 isolated channels. Photograph the label and connectors before acceptance so purchasing and maintenance share the same identity record.
READY TO VERIFY YOUR PART?

Get a IOP301 quote with price, lead time and revision check.

Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, drives and servo motors, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: Amikon Limited sells new and surplus products and develops channels for purchasing such products. Amikon Limited is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because Amikon Limited is not an authorized distributor of this product, the Original Manufacturer's warranty does not apply. Amikon Limited is not an authorized distributor, dealer, or representative of the products displayed on this website. All product names, trademarks, brands, and logos used on this website are the property of their respective owners. The description, explanation, or sale of products with these names, trademarks, brands, and logos is for identification purposes only and is not intended to indicate any association with or authorization from any rights holder.
Product

Product Browsing History