Close Menu
Get Parts Quote
Name
Company *
WhatsApp / WeChat (For Faster Quote) *
Email *
Address
City
State / Province / Region
Zipcode
Country
Quantity *
Part Number *
Manufacturer
Preferred Condition
Additional Information
Cancel
In Stock
Ships by Tuesday, July 7
Fast Shipping Available
Notifier NFS2-640 KDM-2
Notifier NFS2-640 KDM-2
Notifier NFS2-640 KDM-2
· Product image is representative; revision or series may vary. Contact us to request a specific version.

NFS2-640 KDM-2

Intelligent Fire Alarm Control Panel

Require for Quote:

Need more help? You may also find the answer in our FAQ section

Shipping Information

  • For inventory products, we support same day shipping upon payment.
  • For urgent needs, we offer same-day shipping on most items for orders placed before 2:00 PM UTC+8 Simply mention your preferred next-day shipping when place the order, and your order will be prioritized to minimize downtime.
  • For indent items, typical turnaround is 1-3 weeks, depending on parts availability and scarcity.

Technical specifications for NFS2-640 KDM-2

  • Product Model
    NFS2-640 KDM-2
  • Product Parameters
    Intelligent Fire Alarm Control Panel
  • Tariff Code
    8537101190
  • Country of origin
    USA
  • Place of shipment
    Xiamen, China
  • In stock
    1 unit
  • Estimated Shipping Size
    22.2x9.8x3.5cm
  • Manufacturer
    Notifier
  • Weight
    0.5 kg
  • Detection Loops (SLC)
    4 loops
  • Notification Circuits
    10 Class A/B (NACs)
  • Relay Outputs
    5 programmable
  • Event History
    10,000 events
  • Primary Power
    120/240V AC, 50/60Hz
  • Battery Backup
    24V DC, 7-26Ah (up to 90 mins)

Description

The NFS2-640 intelligent Fire Alarm Control Panel is part ofthe ONYX® Series of Fire Alarm Controls from NOTIFIER.In stand-alone or network configurations, ONYX Series products meet virtually every application requirement.The NFS2-640’s modular design makes system planning easier. The panel can be configured with just a few devices forsmall building applications, or networked with many devices toprotect a large campus or a high-rise office block. Simply addadditional peripheral equipment to suit the application.

A host of other options are available, including single- or multichannel voice; firefighter’s telephone; LED, LCD, or PC-basedgraphic annunciators; networking; advanced detection products for challenging environments; wireless fire protection; andmany additional options.

Alternative Names

NFS2-640 KDM/2 NFS2-640  NFS2-64O KDM2 NFSZ-640 KDM-2 NFS2-64O KOM-2

Information

Overview Manuals Circuit Loop Capacity & Protocols Product Applications Field Wiring & Conduit Layout

Features:

  • Intelligent Addressable Fire Alarm Control Panel with FlashScan Protocol
  • One Expandable to Two Isolated SLC Loops (Style 4, 6, or 7)
  • 6.0A Switch-Mode Power Supply with Four Built-In NAC Circuits
  • KDM-R2 Primary Display with 80-Character LCD and QWERTY Keypad
  • High-Speed Network for Up to 200 Nodes
The Notifier NFS2-640 KDM-2 is an Intelligent Fire Alarm Control Panel. The Notifier NFS2-640 KDM-2 is part of the ONYX Series of Fire Alarm Controls from NOTIFIER by Honeywell. The Notifier NFS2-640 KDM-2 is an intelligent addressable fire alarm system.

The Notifier NFS2-640 KDM-2 utilizes FlashScan intelligent features. FlashScan on the Notifier NFS2-640 KDM-2 is an all-digital protocol. FlashScan on the Notifier NFS2-640 KDM-2 polls up to 318 devices in less than two seconds. FlashScan on the Notifier NFS2-640 KDM-2 activates up to 159 outputs in less than five seconds. The microprocessor-based FlashScan detectors on the Notifier NFS2-640 KDM-2 have bicolor LEDs that blink device address during Walk Test.

The NFS2-640 KDM-2 Notifier Intelligent Fire Alarm Control Panel may still be available for purchase and support from Amikon Limited beyond End-Of-Life (EOL) by the manufacturer (OEM).
Notifier NFS2-640 KDM-2 Intelligent Fire Alarm Control Panel Manuals, Datasheets, Drivers, Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
Loop Configuration: Supports up to 2 Signaling Line Circuits (SLCs). The base CPU supports 1 loop; a second loop requires adding an optional LEM-320 expansion module
Device Densities: Each loop accommodates up to 318 intelligent addressable devices. This is broken down into exactly 159 detectors and 159 modules per loop.
FlashScan® Protocol: Utilize the all-digital FlashScan protocol to ensure every loop device is sampled in less than two seconds. It delivers superior noise immunity and lightning-fast output activation compared to legacy CLIP polling.
  • Marine & Offshore VesselsABS-certified for vessels/rigsl
  • Airports & Transit HubsBaggage & passenger terminals
  • Manufacturing PlantsNoise immunity near heavy machines
  • Hospitals & HealthcareLife-safety zoning & zero downtime
This content has been produced using multiple sources.Amikon takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
Power Separation: Maintain a minimum 0.25-inch (6.35 mm) separation between non-power-limited wiring (such as AC power and battery cables) and power-limited circuits (SLC and NAC loops). Route non-power-limited wires through separate conduit entries.Conduit Knockouts: Feed high-voltage AC cables exclusively through the designated knockouts on the top-left or top-rear of the cabinet. Use lower and side knockouts for low-voltage signaling line circuits.

Technical notes

The Notifier NFS2-640 is an intelligent addressable fire alarm control panel part of the Honeywell NOTIFIER ONYX Series. Engineered primarily for mid-sized applications, its modular architecture allows for seamless scaling and networking to protect high-rise buildings or sprawling campuses

FAQs

  • What is the KDM-2?

    +
    The KDM-2 is the primary user interface and keypad for the NFS2-640 panel. It allows you to view system status, silence alarms, reset the system, and program device labels.
  • How many devices can it support?

    +
    Each Signaling Line Circuit (SLC) loop supports up to 318 addressable points.
  • How many loops and circuits are available?

    +
    The base configuration includes 1 SLC loop and 4 Notification Appliance Circuits (NACs), which can be expanded to 4 SLC loops and additional NACs depending on system size.
  • Why is the panel not powering on?

    +
    Verify that AC power is active and the standby batteries are connected. Check the primary circuit boards for tripped fuses or blown surge suppressors.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, drives and servo motors, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: Amikon Limited sells new and surplus products and develops channels for purchasing such products. Amikon Limited is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because Amikon Limited is not an authorized distributor of this product, the Original Manufacturer's warranty does not apply. Amikon Limited is not an authorized distributor, dealer, or representative of the products displayed on this website. All product names, trademarks, brands, and logos used on this website are the property of their respective owners. The description, explanation, or sale of products with these names, trademarks, brands, and logos is for identification purposes only and is not intended to indicate any association with or authorization from any rights holder.
Product

You May Also Like

Product

Product Browsing History

Get a quick price fo NFS2-640 KDM-2
*Quantity
*E-mail
*Mobile
Company
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Amikong please read our privacy policy.