In Stock
Ships by Saturday, August 29
Fast Shipping Available

TPH-LBF-IA1.36.DE.1

Diagnostic Fieldbus Surge Protector

Require for Quote:

Need more help? You may also find the answer in our FAQ section

Shipping Information

  • For inventory products, we support same day shipping upon payment.
  • For urgent needs, we offer same-day shipping on most items for orders placed before 2:00 PM UTC+8 Simply mention your preferred next-day shipping when place the order, and your order will be prioritized to minimize downtime.
  • For indent items, typical turnaround is 1-3 weeks, depending on parts availability and scarcity.

Technical specifications for TPH-LBF-IA1.36.DE.1

  • Product Model
    TPH-LBF-IA1.36.DE.1
  • Spare Model
    TPH-LBF-IA1.36.DE.*
  • Product Parameters
    Diagnostic Fieldbus Surge Protector
  • Tariff Code
    8536300000
  • Country of origin
    Germany
  • Place of shipment
    Xiamen, China
  • In stock
    1 unit
  • Estimated Shipping Size
    2.5x3.54x5.18cm
  • Manufacturer
    Pepperl + Fuchs
  • Weight
    0.1 lbs (0.05 kg)
  • Product type
    Diagnostic fieldbus surge protector
  • Mounting
    Power Hub trunk connection
  • Rated voltage
    36 V
  • Rated current
    600 mA
  • Continuous voltage
    33 V maximum
  • Self current
    6 mA maximum
  • Reaction line to line
    1 ns maximum
  • Reaction line to earth
    100 ns maximum
  • Degree of protection
    IP20
  • Housing material
    Polyamide PA 6.6

Description

Pepperl+Fuchs TPH-LBF-IA1.36.DE.1 is a FieldConnex pluggable surge protector for trunk installation on a fieldbus power hub. It protects FOUNDATION Fieldbus H1 and PROFIBUS PA infrastructure against surge voltages and secondary lightning effects while providing diagnostic status indication. The module is rated for 36 V and 600 mA, has a maximum continuous voltage of 33 V and uses direct shield grounding. The diagnostic version consumes up to 6 mA and provides a green flashing LED for normal status and a red flashing LED when maintenance is required.

Information

Overview Manuals Product Applications Compatibility Lifecycle & Replacement

Features:

  • Pluggable Power Hub trunk surge protector
  • 36 V rated voltage and 600 mA rated current
  • Diagnostic LED for status and maintenance
  • FOUNDATION Fieldbus H1 and PROFIBUS PA support
  • Intrinsically safe hazardous-area approvals

Pepperl+Fuchs TPH-LBF-IA1.36.DE.1 is a FieldConnex diagnostic surge protector designed for installation between a fieldbus Power Hub and its trunk cable. It limits surge voltages and secondary lightning effects while supporting FOUNDATION Fieldbus H1 and PROFIBUS PA communication.


The module is rated for 36 V and 600 mA, accepts up to 33 V continuous voltage and provides direct shield grounding. Its diagnostic circuit flashes green for normal status and red when maintenance is required, allowing segment condition to be checked without changing the protected fieldbus function.


TPH-LBF-IA1.36.DE.1 Pepperl+Fuchs: Verify Power Hub compatibility, grounding, hazardous-area approval, trunk wiring and diagnostic status before commissioning.
Pepperl+Fuchs TPH-LBF-IA1.36.DE.1 FieldConnex Diagnostic Surge Protector Manuals, Datasheets, Official Documents, Links
Important Notice: Amikon PDF documents are independent reference materials prepared from verified Pepperl+Fuchs sources. Use the current controlled Pepperl+Fuchs documentation for installation and commissioning. Accessories, manuals, cables, software, certificates, and other items are not included with this equipment unless listed in the stock item description.
  • Power Hub trunk surge protection
  • FOUNDATION Fieldbus H1 segment protection
  • PROFIBUS PA fieldbus protection
  • Hazardous-area fieldbus installations
  • Lightning protection zone coordination

TPH-LBF-IA1.36.DE.1 is applied where a FieldConnex Power Hub trunk requires surge protection, direct shield grounding and diagnostic status indication. Its approvals and electrical limits must match the fieldbus segment, enclosure and hazardous-area design.

TPH-LBF-IA1.36.DE.1 is intended for Pepperl+Fuchs FieldConnex Power Hub trunk connections using FOUNDATION Fieldbus H1 or PROFIBUS PA physical-layer technology. Confirm the Power Hub version, segment voltage, current, grounding method and enclosure before installation.


Do not use this diagnostic surge protector with the DART Power Hub Backplane MBHD-FB-D*. A replacement must preserve direct shield grounding, hazardous-area certification, terminal arrangement and the diagnostic interface specified for the installed segment.

Confirm the current Pepperl+Fuchs lifecycle status and availability for TPH-LBF-IA1.36.DE.1 before planning a new installation or replacement. Maintain the exact suffix, approval markings and FieldConnex Power Hub compatibility in controlled maintenance records.


Before replacement, isolate the segment according to the approved procedure and document wiring, shield grounding and LED diagnostic status. Surge protectors are not field-repairable; replace a damaged unit with an approved equivalent and repeat the grounding, insulation and communication checks.

Alternative Names

TPHLBFIA136DE1 FieldConnex Power Hub Trunk Surge Protector Diagnostic 36 V Fieldbus Surge Protector

Technical notes

Do not use TPH-LBF-IA1.36.DE.1 with the DART Power Hub Backplane MBHD-FB-D*. Observe hazardous-area certification, grounding and enclosure requirements.

FAQs

  • Which fieldbus systems does TPH-LBF-IA1.36.DE.1 support?

    +
    It supports FOUNDATION Fieldbus H1 and PROFIBUS PA physical-layer systems.
  • What is the main purpose of this surge protector?

    +
    It protects a Power Hub trunk connection against surge voltages and secondary lightning effects.
  • How does the diagnostic LED operate?

    +
    A green flashing LED indicates normal status, while a red flashing LED indicates that maintenance is required.
  • What are the rated electrical values?

    +
    The rated voltage is 36 V, the rated current is 600 mA and the maximum continuous voltage is 33 V.
  • Can it be used in hazardous areas?

    +
    Yes, when the exact approval, enclosure, grounding and installation requirements in the Pepperl+Fuchs documentation are followed.
  • Can it be used with the DART Power Hub Backplane MBHD-FB-D*?

    +
    No. Pepperl+Fuchs specifies that TPH-LBF-IA1.36.DE.1 must not be used with that DART Power Hub backplane.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, drives and servo motors, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: Amikon Limited sells new and surplus products and develops channels for purchasing such products. Amikon Limited is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because Amikon Limited is not an authorized distributor of this product, the Original Manufacturer's warranty does not apply. Amikon Limited is not an authorized distributor, dealer, or representative of the products displayed on this website. All product names, trademarks, brands, and logos used on this website are the property of their respective owners. The description, explanation, or sale of products with these names, trademarks, brands, and logos is for identification purposes only and is not intended to indicate any association with or authorization from any rights holder.
Product

You May Also Like

Product

Product Browsing History

Get a quick price fo TPH-LBF-IA1.36.DE.1
*Quantity
*E-mail
*Mobile
Company
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Amikong please read our privacy policy.