Close Menu
Get Parts Quote
Name
Company *
WhatsApp / WeChat (For Faster Quote) *
Email *
Address
City
State / Province / Region
Zipcode
Country
Quantity *
Part Number *
Manufacturer
Preferred Condition
Additional Information
Cancel
In Stock
Fast Shipping Available
Siemens 6RY1803-0DA03
· Product image is representative; revision or series may vary. Contact us to request a specific version.
Ships by Saturday, September 19

6RY1803-0DA03

Protected power interface module

Shipping Information

  • For inventory products, we support same day shipping upon payment.
  • For urgent needs, we offer same-day shipping on most items for orders placed before 2:00 PM UTC+8 Simply mention your preferred next-day shipping when place the order, and your order will be prioritized to minimize downtime.
  • For indent items, typical turnaround is 1-3 weeks, depending on parts availability and scarcity.
Customs & Documentation

Customs & Documentation

HS classification and country of origin are stated as commercial references and confirmed on the written quotation and shipping documents.

Payment

Payment

Payment is accepted by bank transfer (T/T) in the currencies confirmed in the written quotation.

Product Condition

Product Condition

Product identity, label, visible condition and packing are checked against the written order before dispatch.

Quantity
Mobile *
Country/Region *
E-mail *
Company
Content *
(gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Amikong please read our privacy policy.
  • 20+

    years in automation
  • ISO 9001

    certified quality system
  • 12 months

    amikon warranty
  • 2-hour reply

    from your account manager
  • Success Story

    solutions in action
PRODUCT DESCRIPTION

6RY1803-0DA03 Protected power interface module

Siemens 6RY1803-0DA03 is a Protected power interface module for the SINAMICS DCM. It is used to provides monitored dc output channels. Confirm the exact article, electrical class, interfaces, companion hardware and cooling arrangement before ordering.
ACTUAL APPLICATIONS

Application context for 6RY1803-0DA03

Manufacturer documentation places the Protected Power Interface Module in practical drive applications. The three cases below describe different operating tasks in which 6RY1803-0DA03 performs its documented product-family role with the configured companion equipment.
  • 01 · WATER & WASTEWATER

    Align aeration-blower output during oxygen-setpoint change

    During operation of the blower motors, air headers and oxygen-control loops, 6RY1803-0DA03 serves its documented function as a Protected Power Interface Module. During oxygen-setpoint change, the system uses this function to coordinate blower speed with the required air delivery, helping it match aeration energy to treatment demand.
  • 02 · PULP & PAPER

    Monitor dryer-section control with Protected Power

    As part of the steam groups and dryer drives, 6RY1803-0DA03 supports the configured automation role as a Protected Power Interface Module. During moisture correction, the system uses this function to align thermal and drive response with the running sheet, helping it support the target moisture profile.
  • 03 · MINING & METALS

    Supervise bulk conveying during material surge

    During operation of the feeders, belts and transfer chutes, 6RY1803-0DA03 serves its documented function as a Protected Power Interface Module. During material surge, the system uses this function to adapt equipment demand to material flow, helping it reduce spillage and belt overload.

Technical specifications for 6RY1803-0DA03

  • Product Model
    6RY1803-0DA03
  • Product Parameters
    Protected power interface module
  • In stock
    1 unit
  • Manufacturer
    Siemens
  • Component Class
    Protected power interface module
  • Drive Family
    SINAMICS DCM
  • Primary Function
    Provides monitored DC output channels
  • Power Architecture
    Electronic short-circuit protection
  • Voltage Class
    24 V DC input
  • Current Rating
    Six protected output groups
  • Control Supply
    Two four-pin input plugs
  • Power Section
    DCM power distribution section
  • Mechanical Design
    Terminal-equipped option board
  • Electrical Interface
    X10–X60 and X200 relays
  • Cooling Integration
    Cabinet ambient cooling
  • Board Designation
    6RY1803-0DA03 module
  • Service Role
    A7106-L1 service assembly
  • Product Status
    Siemens spare part
  • Commissioning Check
    Verify fuse LEDs and 40 V clamp
View all additional

Alternative Names

6RY1803 0DA03 SINAMICS DCM Protected power interface module Siemens Protected power interface module
SYSTEM & REPLACEMENT CHECK

Information needed before ordering

Three direct checks to secure your system integration and minimize ordering risks.

Information

System integration Replacement check Manuals & support
DRIVE SYSTEM INTEGRATION

Match 6RY1803-0DA03 to the installed SINAMICS DCM

Siemens 6RY1803-0DA03 is a Protected power interface module used in the SINAMICS DCM.
Confirm voltage class, current rating, section position, interfaces and cooling arrangement before integration.
Use qualified drive-service personnel and follow the applicable Siemens safety, discharge and commissioning procedure.

Features:

  • Exact product identity: 6RY1803-0DA03
  • Product class: Protected power interface module
  • Family: SINAMICS DCM
The Siemens 6RY1803-0DA03 requires documented system integration before energising the drive.
REPLACEMENT CONTROL

Verify the complete 6RY1803-0DA03 identity before exchange

Replace 6RY1803-0DA03 only after matching the full article number, voltage class, module section and connector arrangement.
Photograph every busbar, plug, gate lead, cooling connection and protective-earth point before removal.
After installation, inspect clearances and insulation, restore power in the Siemens sequence and test the affected drive function.

Features:

  • Match exact 6RY1803-0DA03 identity
  • Confirm power-section and phase position
  • Complete insulation and functional tests
The Siemens 6RY1803-0DA03 requires documented replacement verification before energising the drive.
DOCUMENTATION STATUS

Browse the Manuals, Datasheets, Official Documents, Links

Important Notice: Official documents are provided through manufacturer links. Accessories, manuals, cables, calibration data, software and certificates are included only when listed in the quotation.

Features:

  • Technical values prepared for 6RY1803-0DA03
  • Installation checks matched to the drive section
  • Exact article identity required before service
Documentation for Siemens 6RY1803-0DA03 must match the installed drive, power section and revision; confirm manual applicability before service.

Important notice

Manuals, software, firmware, cables, calibration data and accessories are included only when listed in the quotation. AMIKON is an independent supplier and is not affiliated with or authorised by the manufacturer.
This content has been produced using multiple sources. Takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
BUYER INFORMATION

Commercial terms without hidden steps

Your written quote confirms the product identity, price, availability, lead time, warranty and shipping terms before payment.
  • 01

    Shipping & delivery

    Dispatch
    Eligible stock: same / next day
    Carriers
    DHL, FedEx or UPS
    Ship from
    Xiamen, China
    Packed size
    26 × 23 × 3.5 cm
    Shipping weight
    0.82 kg
  • 02

    Payment & customs

    Payment
    Bank transfer (T/T)
    Currencies
    USD · EUR · GBP · RMB
    Credit cards
    Not accepted
    HS reference
    85049090
    Origin
    Austria
  • 03

    Warranty & returns

    Warranty
    12 months from AMIKON
    Inspection
    Label, condition and packing checks
    Returns
    Prior RMA authorisation required
    Compatibility
    Confirm before order
    OEM warranty
    Does not apply
Your written quote confirms the product identity, price, availability, lead time, warranty and shipping terms before payment.
  • Part checked

    Full suffix recorded
  • Condition checked

    Label and appearance
  • Packing checked

    Antistatic protection
  • Tracking supplied

    Established couriers
  • Sandy Lin

    Dedicated account manager · 15+ years
FREQUENTLY ASKED QUESTIONS

Questions buyers ask about 6RY1803-0DA03

Direct answers about identity, compatibility, stock, warranty, payment and shipping.
  • What equipment accepts the auto-reset DCM interface?

    The auto-reset DCM interface is used in the documented SINAMICS DCM configuration for provides monitored dc output channels.
  • How should the 24 V DC · 40 V clamp rating be confirmed for the auto-reset DCM interface?

    For the auto-reset DCM interface, match 24 V DC input and Six protected output groups to the installed equipment nameplate.
  • What happens inside the dcm power distribution section for the auto-reset DCM interface?

    The auto-reset DCM interface performs provides monitored dc output channels through the electronic short-circuit protection.
  • Which marking separates the auto-reset DCM interface?

    For the auto-reset DCM interface, record 6RY1803-0DA03 module together with the complete article and installed revision.
  • Why must x10–x60 and x200 relays be photographed for the auto-reset DCM interface?

    On the auto-reset DCM interface, inspect x10–x60 and x200 relays for keying, damage, contamination, routing and secure seating.
  • What is verified on the two four-pin input plugs for the auto-reset DCM interface?

    Before energizing the auto-reset DCM interface, measure two four-pin input plugs and confirm the documented polarity or phase condition.
  • When is substitution of the auto-reset DCM interface unsafe?

    A auto-reset DCM interface replacement must match its electrical class, section role, companion hardware and mechanical interface.
  • Which result completes commissioning for the auto-reset DCM interface?

    For the auto-reset DCM interface, verify fuse leds and 40 v clamp; then record diagnostics and the controlled functional-test result.
READY TO VERIFY YOUR PART?

Get a 6RY1803-0DA03 quote with price, lead time and revision check.

Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, drives and servo motors, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: Amikon Limited sells new and surplus products and develops channels for purchasing such products. Amikon Limited is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because Amikon Limited is not an authorized distributor of this product, the Original Manufacturer's warranty does not apply. Amikon Limited is not an authorized distributor, dealer, or representative of the products displayed on this website. All product names, trademarks, brands, and logos used on this website are the property of their respective owners. The description, explanation, or sale of products with these names, trademarks, brands, and logos is for identification purposes only and is not intended to indicate any association with or authorization from any rights holder.
Product

Product Browsing History