Siemens 3UA59 40-1J
· Product image is representative; revision or series may vary. Contact us to request a specific version.
Ships by Tuesday, October 20

3UA59 40-1J

Thermal overload relay

Shipping Information

  • For inventory products, we support same day shipping upon payment.
  • For urgent needs, we offer same-day shipping on most items for orders placed before 2:00 PM UTC+8 Simply mention your preferred next-day shipping when place the order, and your order will be prioritized to minimize downtime.
  • For indent items, typical turnaround is 1-3 weeks, depending on parts availability and scarcity.
Customs & Documentation
We prepare clear, order-specific documentation for every international shipment, including the commercial invoice, packing list and available product or compliance documents. Before dispatch, our logistics team confirms the consignee details, declared value, shipping terms and destination requirements with you. Tracking information is provided after shipment, helping your team prepare for import clearance with confidence.
Documents checked before dispatch · Shipment details confirmed · Global tracking provided
Payment
Payment is by bank wire only in RMB/CNY, GBP, EUR or USD. Amikon does not accept credit cards or provide credit terms. Cleared payment is required before shipment unless the written quotation expressly states otherwise.
Product Condition
Factory New These are new and current items that are procured directly from the manufacturer.
New In Sealed Package Parts are new. They have not been used and still have their original package seal intact.
New in Original Package These parts are new. The packages were not originally sealed by their original manufacturer.
Quantity
Mobile *
Country/Region *
E-mail *
Company
Content *
(gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Amikong please read our privacy policy.
  • 20+

    years in automation
  • ISO 9001

    certified quality system
  • 12 months

    amikon warranty
  • 2-hour reply

    from your account manager
  • Success Story

    solutions in action
PRODUCT DESCRIPTION

3UA59 40-1J Thermal overload relay

Siemens 3UA59 40-1J is a thermal overload relay for the Siemens SIRIUS product family. It provides the documented current setting range of 6.3 to 10 A for compatible industrial automation and electrical systems.

The exact article combines the listed electrical, connection and mechanical characteristics for this order code. Verify the complete model, terminal arrangement, ratings and installed system configuration before replacement, wiring or commissioning.
ACTUAL APPLICATIONS

Application context for 3UA59 40-1J

3UA59 40-1J supports documented Siemens SIRIUS functions across production, utilities and infrastructure systems that use the specified interface and electrical ratings.
  • 01 · INDUSTRIAL MANUFACTURING

    Industrial Manufacturing

    Automotive Parts ManufacturingFood and Beverage Processing
  • 02 · WATER AND WASTEWATER

    Water and Wastewater

    Municipal Water TreatmentIndustrial Wastewater Processing
  • 03 · BUILDING INFRASTRUCTURE

    Building Infrastructure

    Commercial Building ServicesPublic Facility Operations

Technical specifications for 3UA59 40-1J

  • Product Model
    3UA59 40-1J
  • Product Parameters
    Thermal overload relay
  • In stock
    7 units
  • Manufacturer
    Siemens
  • Current setting range
    6.3 to 10 A
  • Trip class
    Class 10A
  • Pole count
    3 poles
  • Phase-loss protection
    Integrated
  • Reset selection
    Manual or automatic
  • Auxiliary contacts
    1 NO + 1 NC
  • Rated insulation voltage
    690 V
  • Impulse withstand voltage
    6 kV
  • Ambient compensation
    -25 to +55 °C
  • Test button
    Integrated
  • Trip indicator
    Mechanical green indicator
  • Mounting
    Contactor or independent
View all additional

Alternative Names

3UA59 40 1J Siemens SIRIUS Thermal overload relay Siemens Thermal overload relay 3UA59 40-1J
SYSTEM & REPLACEMENT CHECK

Information needed before ordering

Three direct checks to secure your system integration and minimize ordering risks.

Information

System integration Replacement check Manuals & support
SYSTEM INTEGRATION

Integrate 3UA59 40-1J thermal overload relay

Install 3UA59 40-1J only in the documented Siemens SIRIUS environment after confirming the exact order code, module position and connection method. Match every supply, signal and network interface to the applicable Siemens data before energization.
Use the specified conductor range, terminal arrangement and potential-group design. Preserve cable routing, shielding, polarity and separation from power wiring so the module performs its documented control function.
Commission each affected circuit in a controlled sequence. Verify local indications, controller diagnostics and field operation under safe conditions, then record the final configuration and test result.

Features:

  • Protects three-phase motors against sustained overload current
  • Detects phase loss through the differential bimetal mechanism
  • Compensates trip behavior across the documented ambient-temperature range
The 3UA59 40-1J thermal overload relay requires appropriate configuration before system integration and commissioning.
INTERCHANGEABILITY

Verify 3UA59 40-1J thermal overload relay

Match the complete 3UA59 40-1J order code and every suffix to the installed article. Similar housings within the same Siemens family can have different connections, ratings, diagnostics or supported systems.
Photograph the nameplate, terminal assignments, cable routing, switch positions and adjacent module order before removal. Record the current engineering configuration and any active diagnostic state.
Restore the verified wiring and configuration after replacement. Test each affected power, signal or communication path, confirm normal diagnostics and retain the acceptance record with the asset history.

Features:

  • Provides manual or automatic reset selection after a trip
  • Opens the normally closed contact to release the contactor
  • Closes the normally open contact for trip indication circuits
The 3UA59 40-1J thermal overload relay requires replacement verification against the complete installed configuration and current manufacturer documentation.
DOCUMENTATION STATUS

Browse the Manuals, Datasheets, Official Documents, Links

Important Notice: The linked files are Amikong-hosted reference documents. Match their product identity and scope to the supplied assembly, and consult the applicable manufacturer instructions before use. Accessories and additional documents are included only when expressly listed in the quotation.

Features:

  • Supports direct contactor mounting or independent panel installation
  • Provides a test button for checking the auxiliary trip circuit
  • Displays the tripped state through the mechanical indicator
Documentation for the 3UA59 40-1J thermal overload relay must be checked for document applicability before installation or commissioning.

Important notice

Manuals, software, firmware, cables, calibration data and accessories are included only when listed in the quotation. AMIKON is an independent supplier and is not affiliated with or authorised by the manufacturer.
This content has been produced using multiple sources. Takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
BUYER INFORMATION

Commercial terms without hidden steps

Your written quote confirms the product identity, price, availability, lead time, warranty and shipping terms before payment.
  • 01

    Shipping & delivery

    Dispatch
    Eligible stock: same / next day
    Carriers
    DHL, FedEx or UPS
    Ship from
    Xiamen, China
    Packed size
    5.50 × 9.00 × 8.50 cm
    Shipping weight
    0.28 kg
  • 02

    Payment & customs

    Payment
    Bank transfer (T/T)
    Currencies
    USD · EUR · GBP · RMB
    Credit cards
    Not accepted
    HS reference
    8536490000
    Origin
    Germany
  • 03

    Warranty & returns

    Warranty
    12 months from AMIKON
    Inspection
    Label, condition and packing checks
    Returns
    Prior RMA authorisation required
    Compatibility
    Confirm before order
    OEM warranty
    Does not apply
Your written quote confirms the product identity, price, availability, lead time, warranty and shipping terms before payment.
  • Part checked

    Full suffix recorded
  • Condition checked

    Label and appearance
  • Packing checked

    Antistatic protection
  • Tracking supplied

    Established couriers
  • Sandy Lin

    Dedicated account manager · 15+ years
FREQUENTLY ASKED QUESTIONS

Questions buyers ask about 3UA59 40-1J

Direct answers about identity, compatibility, stock, warranty, payment and shipping.
  • Where does the 3UA59 40-1J thermal overload relay fit?

    Use 3UA59 40-1J only within the documented Siemens SIRIUS arrangement and confirm the stated current setting range of 6.3 to 10 A before connection.
  • Can the 3UA59 40-1J thermal overload relay replace another article?

    Do not decide by appearance alone; match the full order code, current setting range, trip class, terminals and installed hardware configuration.
  • Which details quote the 3UA59 40-1J thermal overload relay?

    Provide the complete 3UA59 40-1J code, quantity, nameplate and connector photos, installed system, required condition and destination country.
  • What arrival checks apply to the 3UA59 40-1J thermal overload relay?

    Check the 3UA59 40-1J label, housing, terminals, accessories, dimensions and documented electrical ratings before removing the installed unit.
  • Which tests commission the 3UA59 40-1J thermal overload relay?

    Verify supply, wiring continuity, local indications, controller diagnostics and the affected field function before returning the equipment to service.
  • Which connection detail governs the 3UA59 40-1J thermal overload relay?

    Confirm the documented trip class of Class 10A together with conductor size, polarity and terminal assignment.
  • How is the 3UA59 40-1J thermal overload relay stored as a spare?

    Keep 3UA59 40-1J dry, protected from static or mechanical damage, and identified by its full order code and verified system assignment.
  • How does a distributor verify the 3UA59 40-1J thermal overload relay?

    Compare the Siemens label, complete suffix, construction, connection layout and key ratings against the approved purchase specification.
READY TO VERIFY YOUR PART?

Get a 3UA59 40-1J quote with price, lead time and revision check.

Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, drives and servo motors, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: Amikon Limited sells new and surplus products and develops channels for purchasing such products. Amikon Limited is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because Amikon Limited is not an authorized distributor of this product, the Original Manufacturer's warranty does not apply. Amikon Limited is not an authorized distributor, dealer, or representative of the products displayed on this website. All product names, trademarks, brands, and logos used on this website are the property of their respective owners. The description, explanation, or sale of products with these names, trademarks, brands, and logos is for identification purposes only and is not intended to indicate any association with or authorization from any rights holder.
Product

Product Browsing History