Siemens 6ES7184-0AA00-0XA0
· Product image is representative; revision or series may vary. Contact us to request a specific version.
Ships by Saturday, November 14

6ES7184-0AA00-0XA0

Compact PROFIBUS Slave Interface

Shipping Information

  • For inventory products, we support same day shipping upon payment.
  • For urgent needs, we offer same-day shipping on most items for orders placed before 2:00 PM UTC+8 Simply mention your preferred next-day shipping when place the order, and your order will be prioritized to minimize downtime.
  • For indent items, typical turnaround is 1-3 weeks, depending on parts availability and scarcity.
Customs & Documentation
We prepare clear, order-specific documentation for every international shipment, including the commercial invoice, packing list and available product or compliance documents. Before dispatch, our logistics team confirms the consignee details, declared value, shipping terms and destination requirements with you. Tracking information is provided after shipment, helping your team prepare for import clearance with confidence.
Documents checked before dispatch · Shipment details confirmed · Global tracking provided
Payment
Payment is by bank wire only in RMB/CNY, GBP, EUR or USD. Amikon does not accept credit cards or provide credit terms. Cleared payment is required before shipment unless the written quotation expressly states otherwise.
Product Condition
Factory New These are new and current items that are procured directly from the manufacturer.
New In Sealed Package Parts are new. They have not been used and still have their original package seal intact.
New in Original Package These parts are new. The packages were not originally sealed by their original manufacturer.
Quantity
Mobile *
Country/Region *
E-mail *
Company
Content *
(gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Amikong please read our privacy policy.
  • 20+

    years in automation
  • ISO 9001

    certified quality system
  • 12 months

    amikon warranty
  • 2-hour reply

    from your account manager
  • Success Story

    solutions in action
PRODUCT DESCRIPTION

LSPM 2 interface for simple PROFIBUS DP slave applications

Siemens 6ES7184-0AA00-0XA0 is the IM 184 PROFIBUS DP slave interface module. It uses an LSPM 2 ASIC and an isolated RS485 interface to connect simple customer devices. The module detects the bus rate automatically and supports communication up to 12 Mbit/s.

Its architecture provides thirty-two configurable input/output bits without the separate microprocessor and firmware requirements shown for IM 183-1. Two host connectors expose the signals and settings, while RUN, BUS-ERROR and DIAGNOSIS indicators support status observation. Host wiring and port configuration remain application-specific.
ACTUAL APPLICATIONS

Industrial Production and Service Sectors

These industry examples describe Siemens' broader market coverage, not verified installations of this exact product. Product suitability depends on the documented configuration and engineering requirements.
  • 01 · TEXTILE MANUFACTURING

    Manufactured Fibers and Textile Finishing

    Manufactured fiber production for the wider textile manufacturing sector.Textile finishing for materials within the commercial fabric industry.
  • 02 · FOOD & BEVERAGE

    Beer and Soft Drink Production

    Beer production within the brewing sector of beverage manufacturing.Soft drink manufacturing for the wider commercial beverage industry.
  • 03 · WATER & WASTEWATER

    Drinking Water and Wastewater Services

    Drinking water production for public and community supply services.Wastewater treatment serving households, communities and industrial water users.

Technical specifications for 6ES7184-0AA00-0XA0

  • Product Model
    6ES7184-0AA00-0XA0
  • Product Parameters
    Compact PROFIBUS Slave Interface
  • Manufacturer
    Siemens
  • Application role
    Simple PROFIBUS DP slave applications
  • Communication protocol
    PROFIBUS DP
  • Communication ASIC
    LSPM 2
  • Maximum data transmission rate
    12 Mbit/s
  • Bus-rate detection
    Automatic
  • I/O signal capacity
    32 input/output bits in total; not 32 inputs plus 32 outputs
  • Separate microprocessor requirement
    Not necessary in the catalog architecture
  • Host connection
    Two 34-pole plug connectors
  • Physical bus interface
    Isolated RS485; 10-pole connector
  • Module supply
    5 V DC via host interface
  • Isolated interface supply
    Separate isolated 5 V generated by host application; fuse required
  • Typical current consumption
    150 mA in catalog; not isolated-interface maximum
  • Permissible environmental temperature
    0 to +70 °C
  • Board dimensions
    Approximately 85 × 64 mm; not packed dimensions
  • Status indicators
    RUN, BUS-ERROR and DIAGNOSIS
View all additional
SYSTEM & REPLACEMENT CHECK

Information needed before ordering

Three direct checks to secure your system integration and minimize ordering risks.

Information

System integration Replacement check Manuals & support
SIMPLE PROFIBUS SLAVE CONNECTIVITY

Define the port arrangement and station identity in the host design

IM 184 uses the LSPM 2 ASIC to connect a simple customer device as a PROFIBUS DP slave. The catalog describes thirty-two input/output bits, while the manual exposes port signals and configuration selections through the host connectors. Define the intended input/output arrangement explicitly; this is not a fixed thirty-two-input plus thirty-two-output module.
Station identity is part of the implementation, not a detail established by the order number. Siemens describes EEPROM or serial host arrangements for the PNO identification and station address, together with jumper selection. Confirm the fitted components and prepared identity data so that a replacement preserves the intended device configuration.
The isolated RS485 circuit requires a separate isolated five-volt supply generated by the customer application, in addition to the module supply. Application-side fusing and external shield termination also form part of the documented arrangement. Keep those host provisions in view when assessing the compact board; isolation is not established by the supply-voltage label alone.

Features:

  • Port configuration rather than fixed I/O allocation
  • EEPROM or serial station-identity arrangement
  • Host-provided isolated power and shielding
The Siemens 6ES7184-0AA00-0XA0 requires the documented hardware configuration, installation conditions and interface arrangement to be verified before system integration and commissioning.
INTERCHANGEABILITY

Verify the complete replacement identity before commissioning

Match 6ES7184-0AA00-0XA0 and the IM 184 slave identity before comparing the installed board. The IM 180 master and IM 183-1 processor-based slave have different architectures. The common twelve-megabit PROFIBUS capability does not establish compatibility, and the manual's 8BA0 documentation number must not be used as the hardware order.
Record the port-setting jumpers, EEPROM or shift-register selection and the station-address arrangement on the existing host. The manual permits settings through jumpers or host signals, so the visible board alone may not reveal the full configuration. Preserve the established mapping instead of applying an assumed factory arrangement to the spare.
Compare the two thirty-four-pole host connections and the ten-pole bus connection with the original wiring record. After the documented commissioning checks, use RUN, BUS-ERROR and DIAGNOSIS indications together with bus communication and application tests. A successful power-on or one normal indicator does not by itself verify the replacement's configured I/O behavior.

Features:

  • Exact slave architecture and order-code match
  • Preserved port and identity settings
  • Host wiring and functional communication checks
The Siemens 6ES7184-0AA00-0XA0 requires replacement verification based on its complete order number, installed hardware, signal configuration and project documentation.
DOCUMENTATION STATUS

Browse the Manuals, Datasheets, Official Documents, Links

Important Notice: Official documents are provided through manufacturer links. Accessories, manuals, cables, calibration data, software, certificates, and other items are not included with this equipment unless listed in the stock item description.

Features:

  • Exact-model manufacturer data and relevant original manual pages
  • Verified manufacturer product reference; separate installation document not supplied
  • Accessories and supplied documentation follow the written quotation
Documentation for the Siemens 6ES7184-0AA00-0XA0 includes an independent technical summary and selected original manufacturer pages; check the applicable document edition against the delivered product and approved installation documentation.

Important notice

Manuals, software, firmware, cables, calibration data and accessories are included only when listed in the quotation. AMIKON is an independent supplier and is not affiliated with or authorised by the manufacturer.
This content has been produced using multiple sources. Takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
BUYER INFORMATION

Commercial terms without hidden steps

Your written quote confirms the product identity, price, availability, lead time, warranty and shipping terms before payment.
  • 01

    Shipping & delivery

    Dispatch
    Eligible stock: same / next day
    Carriers
    DHL, FedEx or UPS
    Ship from
    Xiamen, China
    Packed size
    Confirm final packed dimensions
    Shipping weight
    Confirm final packed weight
  • 02

    Payment & customs

    Payment
    Bank transfer (T/T)
    Currencies
    USD · EUR · GBP · RMB
    Credit cards
    Not accepted
    HS reference
    8517623990
    Origin
    Confirm supplied-unit origin
  • 03

    Warranty & returns

    Warranty
    12 months from AMIKON
    Inspection
    Label, condition and packing checks
    Returns
    Prior RMA authorisation required
    Compatibility
    Confirm before order
    OEM warranty
    Does not apply
Your written quote confirms the product identity, price, availability, lead time, warranty and shipping terms before payment.
  • Part checked

    Full suffix recorded
  • Condition checked

    Label and appearance
  • Packing checked

    Antistatic protection
  • Tracking supplied

    Established couriers
  • Sandy Lin

    Dedicated account manager · 15+ years
FREQUENTLY ASKED QUESTIONS

Questions buyers ask about 6ES7184-0AA00-0XA0

Direct answers about identity, compatibility, stock, warranty, payment and shipping.
  • Is IM 184 a PROFIBUS master?

    No. Both the exact Siemens ordering table and the IM 184 user description identify it as a PROFIBUS DP slave module. Its role is different from the neighboring IM 180 master interface.
  • Does thirty-two I/O bits mean thirty-two inputs and thirty-two outputs?

    No. The catalog states thirty-two input/output bits for IM 184. The host interface exposes ports whose direction and configuration are selected for the application. Do not double that capacity or describe them as thirty-two inputs plus thirty-two outputs.
  • Does IM 184 need an onboard user processor?

    The catalog lists no separate microprocessor requirement for IM 184. The LSPM2 ASIC performs its documented slave-interface role. This differs from the processor-and-firmware architecture of IM 183-1 and does not make the two modules interchangeable.
  • How are station address and PNO identity handled?

    The manual describes an EEPROM or external serial arrangement for reading the station address and PNO identification. An EEPROM must already contain the required PNO identity; its presence or programming must not be assumed from the module order number.
  • What do the three indicators show?

    Siemens identifies RUN, BUS-ERROR and DIAGNOSIS indications. Related signals are also exposed to the host. Interpret them with the original host configuration and manual; an illuminated RUN indicator alone does not prove that all bus data and application functions are correct.
  • Does one five-volt input cover both the electronics and isolated interface?

    The user description separates the control-electronics supply from an isolated five-volt supply for RS485, both provided through the host connections. It also requires application-side fusing. Verify the host circuit rather than treating the catalog voltage as a complete connection instruction.
  • Can all IM 184 port settings be left at an assumed default?

    No. The manual documents jumper or host-signal settings for port configuration and selection between EEPROM and shift-register arrangements. Record the installed configuration and compare it with the replacement; the hardware order code does not establish the application-specific settings.
READY TO VERIFY YOUR PART?

Get a 6ES7184-0AA00-0XA0 quote with price, lead time and revision check.

Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, drives and servo motors, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: Amikon Limited sells new and surplus products and develops channels for purchasing such products. Amikon Limited is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because Amikon Limited is not an authorized distributor of this product, the Original Manufacturer's warranty does not apply. Amikon Limited is not an authorized distributor, dealer, or representative of the products displayed on this website. All product names, trademarks, brands, and logos used on this website are the property of their respective owners. The description, explanation, or sale of products with these names, trademarks, brands, and logos is for identification purposes only and is not intended to indicate any association with or authorization from any rights holder.
Product

Product Browsing History