Close Menu
Get Parts Quote
Name
Company *
WhatsApp / WeChat (For Faster Quote) *
Email *
Address
City
State / Province / Region
Zipcode
Country
Quantity *
Part Number *
Manufacturer
Preferred Condition
Additional Information
Cancel
TESCH F121×04
TESCH F121×04
TESCH F121×04
TESCH F121×04
TESCH F121×04
TESCH F121×04
· Product image is representative; revision or series may vary. Contact us to request a specific version.

F121×04

F121 safety relay

Shipping Information

  • For inventory products, we support same day shipping upon payment.
  • For urgent needs, we offer same-day shipping on most items for orders placed before 2:00 PM UTC+8 Simply mention your preferred next-day shipping when place the order, and your order will be prioritized to minimize downtime.
  • For indent items, typical turnaround is 1-3 weeks, depending on parts availability and scarcity.
Customs & Documentation
We prepare clear, order-specific documentation for every international shipment, including the commercial invoice, packing list and available product or compliance documents. Before dispatch, our logistics team confirms the consignee details, declared value, shipping terms and destination requirements with you. Tracking information is provided after shipment, helping your team prepare for import clearance with confidence.
Documents checked before dispatch · Shipment details confirmed · Global tracking provided
Payment
Payment is by bank wire only in RMB/CNY, GBP, EUR or USD. Amikon does not accept credit cards or provide credit terms. Cleared payment is required before shipment unless the written quotation expressly states otherwise.
Product Condition
Factory New These are new and current items that are procured directly from the manufacturer.
New In Sealed Package Parts are new. They have not been used and still have their original package seal intact.
New in Original Package These parts are new. The packages were not originally sealed by their original manufacturer.
Quantity
Mobile *
Country/Region *
E-mail *
Company
Content *
(gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Amikong please read our privacy policy.
  • 20+

    years in automation
  • ISO 9001

    certified quality system
  • 12 months

    amikon warranty
  • 2-hour reply

    from your account manager
  • Success Story

    solutions in action
PRODUCT DESCRIPTION

F121×04 F121 safety relay

TESCH F121×04 is a safety relay for hardwired emergency-stop and monitored-reset circuits. It has three normally open safety contacts, one normally closed auxiliary contact and a short-circuit-protected semiconductor output.

The relay supports Category 4 safety arrangements with Category 0 stopping. Documented supply variants include 24 V AC/DC and several AC voltage options; the selected variant must be identified from its label. Its IP20 terminals, IP40 housing and specified reset response times define the installation limits.
ACTUAL APPLICATIONS

Application fields for F121×04

Three model-specific application areas are listed for F121×04, with two related application fields under each heading.
  • 01 · INDUSTRIAL MANUFACTURING

    Discrete Manufacturing and Industrial Assembly

    Automotive component manufacturing and precision assemblyIndustrial materials processing and product assembly
  • 02 · CHEMICAL PROCESSING

    Chemical and Pharmaceutical Production

    Chemical formulation and batch production areasPharmaceutical manufacturing and regulated processing areas
  • 03 · WAREHOUSING & LOGISTICS

    Distribution and Material Handling

    Warehouse distribution and order fulfillment areasBulk materials handling and logistics areas

Technical specifications for F121×04

  • Product Model
    F121×04
  • Product Parameters
    F121 safety relay
  • Manufacturer
    TESCH
  • Safety category
    Category 4
  • Stop category
    Category 0
  • Safety contacts
    3 NO
  • Auxiliary contact
    1 NC
  • Semiconductor output
    1, short-circuit protected
  • Rated supply options
    230 / 115 / 42 V AC; 24 V AC/DC
  • Power consumption
    4 W
  • Rated insulation voltage
    250 V
  • Test voltage
    2.5 kV
  • Terminal protection
    IP20
  • Housing protection
    IP40
  • Ambient temperature
    −5 to +55 °C
  • Monitored reset response
    <60 ms
  • Automatic reset response
    <600 ms
  • Emergency-stop release
    <20 ms
View all additional

Alternative Names

F121×04 F121 machine safety relays F121 safety relay TESCH F121 safety relay
SYSTEM & REPLACEMENT CHECK

Information needed before ordering

Three direct checks to secure your system integration and minimize ordering risks.

Information

System integration Replacement check Manuals & support
SYSTEM INTEGRATION

Integrate F121×04 with the documented configuration

Match the 24 V AC/DC supply and the three normally-open safety outputs to the validated machine safety circuit. The F121×04 has three normally open safety contacts, one normally closed auxiliary contact and a Y31–Y32 status output.
Verify monitored or automatic reset selection, feedback-loop wiring and cross-fault detection before energizing the relay. Use the documented 24 V AC/DC supply variant and verify the X5/S33 feedback loop, reset selection and cross-fault detection.
Confirm the required Category 4 architecture and Stop Category 0 behavior through a controlled safety-function test.

Features:

  • Exact F121×04 identity
  • 24 V AC/DC safety-control variant
  • hardwired safety contacts
Use the complete F121×04 identity and its documented electrical and interface values when integrating the F121 safety relay. Verify the installed configuration before commissioning.
INTERCHANGEABILITY

Verify F121×04 before replacement

Record the F121×04 suffix, supply version, terminal wiring and reset mode before removing the installed relay. The F121×04 has three normally open safety contacts, one normally closed auxiliary contact and a Y31–Y32 status output.
Check the replacement for three safety contacts, one auxiliary contact and the semiconductor status output. Use the documented 24 V AC/DC supply variant and verify the X5/S33 feedback loop, reset selection and cross-fault detection.
After installation, test emergency-stop release time, contact feedback and every connected guard or light-curtain function.

Features:

  • Complete label and revision
  • Recorded wiring and configuration
  • Controlled post-installation functional test
Match the complete F121×04 marking and the installed configuration before replacement. Preserve the approved settings and verify the relevant electrical and interface functions after installation.
DOCUMENTATION STATUS

Browse the Manuals, Datasheets, Official Documents, Links

Important Notice: Official documents are provided through manufacturer links. Accessories, manuals, cables, calibration data, software and certificates are included only when listed in the quotation.

Features:

  • Exact-model technical data for F121×04
  • Applicable TESCH documentation
  • Directory links by subcategory and brand
Documentation for F121×04 must be matched to the complete article identity and installed configuration before use.

Also searched as

Important notice

Manuals, software, firmware, cables, calibration data and accessories are included only when listed in the quotation. AMIKON is an independent supplier and is not affiliated with or authorised by the manufacturer.
This content has been produced using multiple sources. Takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
BUYER INFORMATION

Commercial terms without hidden steps

Your written quote confirms the product identity, price, availability, lead time, warranty and shipping terms before payment.
  • 01

    Shipping & delivery

    Dispatch
    Eligible stock: same / next day
    Carriers
    DHL, FedEx or UPS
    Ship from
    Xiamen, China
    Packed size
    11.4 × 9.9 × 4.5 cm
    Shipping weight
    0.37 kg
  • 02

    Payment & customs

    Payment
    Bank transfer (T/T)
    Currencies
    USD · EUR · GBP · RMB
    Credit cards
    Not accepted
    HS reference
    85364900
    Origin
    Germany
  • 03

    Warranty & returns

    Warranty
    12 months from AMIKON
    Inspection
    Label, condition and packing checks
    Returns
    Prior RMA authorisation required
    Compatibility
    Confirm before order
    OEM warranty
    Does not apply
Your written quote confirms the product identity, price, availability, lead time, warranty and shipping terms before payment.
  • Part checked

    Full suffix recorded
  • Condition checked

    Label and appearance
  • Packing checked

    Antistatic protection
  • Tracking supplied

    Established couriers
  • Sandy Lin

    Dedicated account manager · 15+ years
FREQUENTLY ASKED QUESTIONS

Questions buyers ask about F121×04

Direct answers about identity, compatibility, stock, warranty, payment and shipping.
  • Which F121×04 supply version is being supplied?

    Check the voltage printed on the relay label. The family has 230, 115 and 42 V AC and 24 V AC/DC variants; the supply circuit must match the particular unit.
  • How many safety contacts does F121×04 provide?

    The documented arrangement has three normally open safety contacts and one normally closed auxiliary contact. Check the terminal diagram against the installed wiring.
  • Can its auxiliary contact replace a safety output?

    No. The single normally closed contact is auxiliary; confirm that the required safety function uses the three designated safety contacts.
  • What reset arrangement should maintenance record?

    Record whether the installed circuit uses monitored or automatic reset and photograph the feedback-loop terminals before exchange.
  • What is the function of Y31–Y32?

    It is a semiconductor status output. Confirm its role in the existing indication circuit rather than treating it as another safety contact.
  • Which safety category applies to this relay?

    The documented relay is Category 4 with Stop Category 0 capability. The completed safety function still needs validation in the installed circuit.
  • What evidence should a distributor request before quoting?

    Request the complete F121×04 label, supply-voltage marking, terminal photograph and required contact arrangement.
  • What should be tested after replacement?

    Test the emergency-stop release, contact feedback, reset behavior and every connected guard function before restoring operation.
READY TO VERIFY YOUR PART?

Get a F121×04 quote with price, lead time and revision check.

Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, drives and servo motors, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: Amikon Limited sells new and surplus products and develops channels for purchasing such products. Amikon Limited is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because Amikon Limited is not an authorized distributor of this product, the Original Manufacturer's warranty does not apply. Amikon Limited is not an authorized distributor, dealer, or representative of the products displayed on this website. All product names, trademarks, brands, and logos used on this website are the property of their respective owners. The description, explanation, or sale of products with these names, trademarks, brands, and logos is for identification purposes only and is not intended to indicate any association with or authorization from any rights holder.
Product