GSI130 244-130-000-204

Galvanic Separation Unit

Require for Quote:

Need more help? You may also find the answer in our FAQ section

Shipping Information

  • For inventory products, we support same day shipping upon payment.
  • For urgent needs, we offer same-day shipping on most items for orders placed before 2:00 PM UTC+8 Simply mention your preferred next-day shipping when place the order, and your order will be prioritized to minimize downtime.
  • For indent items, typical turnaround is 1-3 weeks, depending on parts availability and scarcity.

Technical specifications for GSI130 244-130-000-204

  • Product Model
    GSI130 244-130-000-204
  • Product Parameters
    Galvanic Separation Unit
  • Tariff Code
    8537101190
  • Country of origin
    SWEDEN
  • Place of shipment
    Xiamen, China
  • In stock
    1 unit
  • Estimated Shipping Size
    7.8x5.3x4.8cm
  • Manufacturer
    Vibro-Meter
  • Weight
    0.2 kg
  • Supply voltage (to GSI)
    +24 V ±5%
  • Ripple (100 Hz)
    100 mV pp max
  • No load : Approx
    20 mA
  • Short-circuit
    Max. 120 mA
  • Short-circuit current
    60 mA
  • Pass-band
    DC to 10 kHz ±0.5%, -1 dB at20 kHz
  • Transfer function
    1 V/mA factory set

Description

The GSI 122/130 galvanic separation unit is used forsupplying transducers and conditioners and for reading off signals given by them.It is used in 2-wire transmission systems. In a moregeneral application it serves for supplying any electronic system with a consumption of less than 20 mA.This unit outputs a voltage signal proportional to thecurrent consumed by the conditioner. This voltagesignal is directly available for analysis of the conditioner signal.

The GSI 122/130 module avoids any problems dueto voltage differences between the measuring pointand the signal processing (e.g. earth loops).The GSI 122 Version 20x conforms to the CENELECand CSA standards concerning the powering of transducers and conditioners mounted in explosive areas.The use of the GSI 122/130 in an installation avoidsthe need to mount Zener barriers, which generateadditional voltages drops and limit the length of thetransmission line and the dynamic range of the system.

Alternative Names

GSI130-244-130-000-204 GSI130/244-130-000-204 GSI 130 244-130-000-204 GSI130 244 130 000 204 GSI 130 244 130 000 204 GSI13O 244 13O OOO 2O4 GS1 I30 244 I30 000 204

Information

Overview Manuals Application Notes Product Applications Electrical Connections

Features:

  • Vibration monitoring
  • Long distance signal transmission
  • CENELEC / PTB approved
  • CSA approved
The GSI 122/130 module avoids any problems dueto voltage differences between the measuring pointand the signal processing (e.g. earth loops).The GSI 122 Version 20x conforms to the CENELECand CSA standards concerning the powering of transducers and conditioners mounted in explosive areas.

The use of the GSI 122/130 in an installation avoidsthe need to mount Zener barriers, which generateadditional voltages drops and limit the length of thetransmission line and the dynamic range of the system.

The GSI 130 244-130-000-204 Vibro-Meter Galvanic Separation Units may still be available for purchase and support from Amikon Limited beyond End-Of-Life (EOL) by the manufacturer (OEM).
Vibro-Meter GSI 130 244-130-000-204 Galvanic Separation Units Manuals, Datasheets, Drivers, Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
Signal Conditioning & Conversion: Converts a 2-wire current-modulated input into a standard proportional voltage signal 
Electrical Isolation : Provides essential electrical isolation between the sensor/field measuring chain and your control or monitoring system, preventing ground loops and electrical interference.
Long-Distance Transmission: Supports 2-wire transmission techniques, allowing for clean, reliable signal transmission between the field sensor and monitoring electronics over long distances.
  • Gas Turbine Combustor Monitoring:Tracks dynamic pressure pulsations to prevent acoustic fatigue
  • Power Generation Facilities:Nuclear/hydro/thermal: safeguards high-vibration zones
  • Oil Refining and Petrochemical Processing:Tracks rapid pressure fluctuations in compressors/pumps
  • Automated Assembly Lines:Step-by-step diagnostics & cycle tracking for auto/electronics
  • Hazardous Industrial Zones:Class I Div2: oil/gas, chemical mixers & paint booths
This content has been produced using multiple sources.Amikon takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
Grounding: Always connect the chassis or DIN rail to a clean, low-impedance earth to ensure proper noise shielding and safety.
Input : Connect the signal and return lines from your transducer (e.g., IPC 704 signal conditioner) to the designated input terminals on the GSI 130. Ensure the shielding of the cable is properly terminated on the ground lug.
Output : Connect the isolated output terminals to your monitoring system . The GSI 130 typically operates with a transfer function of 1 V/mA (translating current signals into standard voltage signals).
Power Supply: Connect the DC power source (usually 24 VDC) to the respective power terminals, paying close attention to the correct polarity.

Technical notes

The GSI130 extends signal transmission distances up to 1 kilometre when used with current output configurations, maintaining signal integrity over long cable runs. The unit operates on 24 VDC power supply or in loop-powered configurations depending on the specific variant. Environmental operation spans –20°C to +60°C with storage capability from –25°C to +70°C. The IP20 protection rating designates the unit for indoor control cabinet installation.

FAQs

  • What is the difference between the GSI 130 and GSI 122?

    +
    The GSI 122 is specifically designed for explosive atmospheres requiring intrinsic safety (Ex i), whereas the GSI 130 is intended for standard, non-explosive (non-Ex i) industrial applications.
  • What is the recommended power supply?

    +
    The unit requires a nominal supply voltage of +24 V ±5% and consumes very little power since it is principally designed to serve electronic systems that draw less than 20 mA.
  • What is the signal pass-band range?

    +
    The pass-band is generally DC to 10 kHz (± 0.5%), with a -1 dB drop-off at 20 kHz.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, drives and servo motors, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: Amikon Limited sells new and surplus products and develops channels for purchasing such products. Amikon Limited is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because Amikon Limited is not an authorized distributor of this product, the Original Manufacturer's warranty does not apply. Amikon Limited is not an authorized distributor, dealer, or representative of the products displayed on this website. All product names, trademarks, brands, and logos used on this website are the property of their respective owners. The description, explanation, or sale of products with these names, trademarks, brands, and logos is for identification purposes only and is not intended to indicate any association with or authorization from any rights holder.
Product

You May Also Like

Product

Product Browsing History

Get a quick price fo GSI130 244-130-000-204
*Quantity
*E-mail
*Mobile
Company
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Amikong please read our privacy policy.