ABB CM578-CN
· Product image is representative; revision or series may vary. Contact us to request a specific version.
Ships by Saturday, September 19

CM578-CN

CANopen Master Communication Module

Shipping Information

  • For inventory products, we support same day shipping upon payment.
  • For urgent needs, we offer same-day shipping on most items for orders placed before 2:00 PM UTC+8 Simply mention your preferred next-day shipping when place the order, and your order will be prioritized to minimize downtime.
  • For indent items, typical turnaround is 1-3 weeks, depending on parts availability and scarcity.
Customs & Documentation
We prepare clear, order-specific documentation for every international shipment, including the commercial invoice, packing list and available product or compliance documents. Before dispatch, our logistics team confirms the consignee details, declared value, shipping terms and destination requirements with you. Tracking information is provided after shipment, helping your team prepare for import clearance with confidence.
Documents checked before dispatch · Shipment details confirmed · Global tracking provided
Payment
Payment is by bank wire only in RMB/CNY, GBP, EUR or USD. Amikon does not accept credit cards or provide credit terms. Cleared payment is required before shipment unless the written quotation expressly states otherwise.
Product Condition
Factory New These are new and current items that are procured directly from the manufacturer.
New In Sealed Package Parts are new. They have not been used and still have their original package seal intact.
New in Original Package These parts are new. The packages were not originally sealed by their original manufacturer.
Quantity
Mobile *
Country/Region *
E-mail *
Company
Content *
(gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Amikong please read our privacy policy.
  • 20+

    years in automation
  • ISO 9001

    certified quality system
  • 12 months

    amikon warranty
  • 2-hour reply

    from your account manager
  • Success Story

    solutions in action
PRODUCT DESCRIPTION

CM578-CN connects CANopen devices to AC500

ABB CM578-CN enables CANopen communication for the documented AC500 CPU families. It exchanges controller data through the terminal-base communication interface and connects to the fieldbus through a removable five-pin COMBICON connector.

Order 1SAP170800R0001 is the standard CM578-CN, distinct from the XC order. ABB datasheet revision 2 lists both variants as Classic. Preserve the installed CANopen configuration, node identities and applicable environmental conditions when evaluating a replacement.
ACTUAL APPLICATIONS

Where CM578-CN integrates CANopen device profiles

ABB describes profiles for I/O, drives and encoders and explains the shared object-dictionary mechanism. The following are engineering scenarios based on that documentation, not named customer cases.
  • 01 · REMOTE I/O

    Map field-node process data

    Integrate compatible digital or analog CANopen I/O nodes through their device descriptions. Preserve the object-dictionary mapping and valid node addresses in the controller project. Check the actual input and output behavior after the communication state has been established.
  • 02 · DRIVE PROFILES

    Exchange drive-related information

    Connect compatible CANopen drive devices using the applicable device profile and EDS identity. Validate the intended control and status mapping rather than relying on physical bus connection alone. Test the engineered sequence and equipment interlocks before automatic operation.
  • 03 · ENCODER DATA

    Acquire configured encoder values

    Read compatible CANopen encoder data through the specified device objects and project mapping. Confirm the actual encoder identity and interpretation of its reported values. Compare the received information with a controlled physical movement before accepting the measurement path.

Technical specifications for CM578-CN

  • Product Model
    CM578-CN
  • Product Parameters
    CANopen Master Communication Module
  • In stock
    1 unit
  • Manufacturer
    ABB
  • Transmission-rate range
    10 kbit/s to 1 Mbit/s
  • Documented CPU families
    PM57x, PM58x and PM59x
  • Supported terminal bases
    All TB5xx listed by ABB
  • Field connector
    Pluggable five-pin COMBICON
  • Connector allocation
    1 CAN_GND; 2 CAN_L; 3 CAN_SHLD; 4 CAN_H; 5 unused
  • Module power path
    Via the communication-module interface of the terminal base
  • Typical CPU-base 24 V current
    50 mA
  • Typical communication-bus current
    290 mA
  • Dual-port memory
    8 kByte
  • Internal RAM
    256 kByte
  • Firmware flash memory
    512 kByte
  • CANopen addressing
    Slave node addresses 1-127
  • Cable-length examples
    30 m at 1 Mbit/s; 100 m at 500 kbit/s; 500 m at 125 kbit/s
  • Horizontal operating ambient
    0-60 C for the standard AC500 version
  • Ingress protection
    IP20
View all additional

Alternative Names

CM578-CN 1SAP170800R0001 CM578 CN CANopen master
SYSTEM & REPLACEMENT CHECK

Information needed before ordering

Three direct checks to secure your system integration and minimize ordering risks.

Information

System integration Replacement check Manuals & support
CANOPEN PROFILE INTEGRATION

Preserve the object dictionary and node configuration

ABB CM578-CN enables CANopen communication for the documented AC500 CPU families. It exchanges controller data through the terminal-base communication interface and connects to the fieldbus through a removable five-pin COMBICON connector.
CANopen device descriptions identify communication parameters and device-specific objects. Record the correct EDS and node address for each connected device and verify that the application mapping uses the intended objects.
The standard CM578-CN uses the documented pin allocation with pin 5 unused. Keep the CPU-base 24 V budget distinct from the communication-bus current, and verify the selected rate, cable length and data-line termination.

Features:

  • Match standard order 1SAP170800R0001
  • Validate field-device EDS and object mapping
  • Check node states and application data
The ABB CM578-CN requires verified CANopen node identities and object mappings before system integration and commissioning.
INTERCHANGEABILITY

Verify the complete replacement identity before commissioning

ABB datasheet 3ADR010018 revision 2, dated 2018-05-04, lists standard CM578-CN order 1SAP170800R0001 as Classic. It advises using Active products for new installation planning; obtain current migration guidance for a new design.
For an installed replacement, retain the CPU and terminal-base identity, CANopen configuration, EDS files and device addresses. Confirm that the supplied module is the standard version rather than assuming XC qualification from a similar housing.
Perform replacement with supply and process voltages isolated. Restore the recorded bus settings and then validate node states, process-data mapping and the actual connected device behavior.

Features:

  • Record standard versus XC identity
  • Preserve EDS files and node configuration
  • Verify device data and application operation
The ABB CM578-CN requires replacement verification of its variant identity, CANopen objects and node configuration before commissioning.
DOCUMENTATION STATUS

Browse the Manuals, Datasheets, Official Documents, Links

Important Notice: The Amikon manual combines the exact CM578-CN hardware section with the standard-version pages from ABB revision 2. XC-only environmental pages are excluded. Confirm applicability to the installed controller version.

Features:

  • CM578-CN documents distinguish NMT roles, EDS data and standard-version limits
  • Software licensing and project backups remain the customer's responsibility
  • Accessories are supplied only when listed in the quotation
Documentation for the ABB CM578-CN must match the intended CANopen device configuration and ordered variant; confirm manual availability in the written quotation.

Important notice

Manuals, software, firmware, cables, calibration data and accessories are included only when listed in the quotation. AMIKON is an independent supplier and is not affiliated with or authorised by the manufacturer.
This content has been produced using multiple sources. Takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
BUYER INFORMATION

Commercial terms without hidden steps

Your written quote confirms the product identity, price, availability, lead time, warranty and shipping terms before payment.
  • 01

    Shipping & delivery

    Dispatch
    Eligible stock: same / next day
    Carriers
    DHL, FedEx or UPS
    Ship from
    Xiamen, China
    Packed size
    13.4 × 7.3 × 4.3 cm
    Shipping weight
    0.16 kg
  • 02

    Payment & customs

    Payment
    Bank transfer (T/T)
    Currencies
    USD · EUR · GBP · RMB
    Credit cards
    Not accepted
    HS reference
    8517620000
    Origin
    Switzerland
  • 03

    Warranty & returns

    Warranty
    12 months from AMIKON
    Inspection
    Label, condition and packing checks
    Returns
    Prior RMA authorisation required
    Compatibility
    Confirm before order
    OEM warranty
    Does not apply
Your written quote confirms the product identity, price, availability, lead time, warranty and shipping terms before payment.
  • Part checked

    Full suffix recorded
  • Condition checked

    Label and appearance
  • Packing checked

    Antistatic protection
  • Tracking supplied

    Established couriers
  • Sandy Lin

    Dedicated account manager · 15+ years
FREQUENTLY ASKED QUESTIONS

Questions buyers ask about CM578-CN

Direct answers about identity, compatibility, stock, warranty, payment and shipping.
  • Can a DeviceNet plug with power on pin 5 be reused unchanged on CM578-CN?

    No. ABB identifies pin 5 of the CM578-CN CANopen connector as unused, with CAN_GND on pin 1. Do not transfer the DeviceNet power-pin assignment to this connector.
  • Why are both 50 mA and 290 mA listed for CM578-CN consumption?

    They refer to different supply interfaces. The revision-2 datasheet lists typically 50 mA at the CPU terminal-base 24 V supply and typically 290 mA over the communication-module bus. Use the value appropriate to the power budget being evaluated.
  • Does a CANopen network capacity of 128 devices mean 128 slave addresses?

    No. ABB describes one NMT master and up to 127 NMT slaves, with slave addresses from 1 to 127. The total device figure must not be used as a 128-slave allowance.
  • What information does an EDS contribute to a CM578-CN project?

    ABB describes the Electronic Data Sheet as the standardized representation of a CANopen device and its object dictionary. It identifies communication and device-specific functionality; match the EDS to the actual field device rather than treating it as the controller application.
  • Does NMT master status mean only CM578-CN can transmit operational messages?

    No. ABB explains that all devices can transmit in operational mode, while the master can change slave operating modes. CANopen master/slave terminology should not be treated as identical to a strictly polled bus architecture.
  • Does an illuminated yellow STA lamp itself indicate a CM578-CN fault?

    No. The dedicated LED table says STA on indicates that the CANopen master is transmitting data. The separate red ERR indicator reports a CANopen error.
  • Does identical construction make the standard CM578-CN an XC module?

    No. The standard order is 1SAP170800R0001; the XC order is 1SAP370800R0001. ABB assigns different system-data sections to the two variants, so environmental qualification must follow the actual ordered version.
  • What does the Classic entry mean when considering CM578-CN for a new installation?

    ABB revision 2 lists CM578-CN as Classic and advises using Active modules for planning and commissioning new installations. Review the current replacement path with ABB; the historical Classic entry is not an Active-status claim.
READY TO VERIFY YOUR PART?

Get a CM578-CN quote with price, lead time and revision check.

Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, drives and servo motors, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: Amikon Limited sells new and surplus products and develops channels for purchasing such products. Amikon Limited is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because Amikon Limited is not an authorized distributor of this product, the Original Manufacturer's warranty does not apply. Amikon Limited is not an authorized distributor, dealer, or representative of the products displayed on this website. All product names, trademarks, brands, and logos used on this website are the property of their respective owners. The description, explanation, or sale of products with these names, trademarks, brands, and logos is for identification purposes only and is not intended to indicate any association with or authorization from any rights holder.
Product

Product Browsing History