In Stock
Fast Shipping Available
ABB DA502
· Product image is representative; revision or series may vary. Contact us to request a specific version.
Ships by Thursday, September 10

DA502

Mixed Signal Output Module

Shipping Information

  • For inventory products, we support same day shipping upon payment.
  • For urgent needs, we offer same-day shipping on most items for orders placed before 2:00 PM UTC+8 Simply mention your preferred next-day shipping when place the order, and your order will be prioritized to minimize downtime.
  • For indent items, typical turnaround is 1-3 weeks, depending on parts availability and scarcity.
Customs & Documentation
We prepare clear, order-specific documentation for every international shipment, including the commercial invoice, packing list and available product or compliance documents. Before dispatch, our logistics team confirms the consignee details, declared value, shipping terms and destination requirements with you. Tracking information is provided after shipment, helping your team prepare for import clearance with confidence.
Documents checked before dispatch · Shipment details confirmed · Global tracking provided
Payment
Payment is by bank wire only in RMB/CNY, GBP, EUR or USD. Amikon does not accept credit cards or provide credit terms. Cleared payment is required before shipment unless the written quotation expressly states otherwise.
Product Condition
Factory New These are new and current items that are procured directly from the manufacturer.
New In Sealed Package Parts are new. They have not been used and still have their original package seal intact.
New in Original Package These parts are new. The packages were not originally sealed by their original manufacturer.
Quantity
Mobile *
Country/Region *
E-mail *
Company
Content *
(gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Amikong please read our privacy policy.
  • 20+

    years in automation
  • ISO 9001

    certified quality system
  • 12 months

    amikon warranty
  • 2-hour reply

    from your account manager
  • Success Story

    solutions in action
PRODUCT DESCRIPTION

DA502 combines digital actuation with analog field signals

ABB DA502 combines sixteen fixed transistor outputs with eight configurable digital input/output channels, four analog inputs and two analog outputs. This S500 module supports output-oriented field stations that also need electrical or temperature measurements.

The standard DA502 is order 1SAP250800R0001 and uses TU515 or TU516 terminal units. Match the fixed-output bank, configurable channels and analog signal ranges to the controller project. Observe the group-current limits instead of multiplying a single-channel rating across every output.
ACTUAL APPLICATIONS

Where DA502 supports output-oriented field stations

The documented output banks and analog channels support the following integration tasks. Select the actual field circuits and validate their behavior; no named customer installation is implied.
  • 01 · OUTPUT SEQUENCING

    Command multiple discrete field loads

    Connect separate 24 V field loads to the fixed transistor-output bank. Build the load schedule around the documented 4 A bank limit rather than the sum of individual channel ratings. Apply the required mounting derating and verify each commanded circuit before automatic operation.
  • 02 · ANALOG FEEDBACK

    Pair measured feedback with analog commands

    Acquire documented voltage, current or RTD measurements while issuing compatible analog command signals. Match each receiver and sensor to its configured range and reference terminal. Validate the relationship between commanded values and returned measurements in the actual control application.
  • 03 · MIXED FIELD STATES

    Allocate configurable channels to local needs

    Use the eight configurable digital channels for the required mix of field-state inputs and transistor outputs. Preserve their separate bank assignment in the project and wiring schedule. Check the input waveform and output-bank loading with the installed equipment before release.

Technical specifications for DA502

  • Product Model
    DA502
  • Product Parameters
    Mixed Signal Output Module
  • In stock
    1 unit
  • Manufacturer
    ABB
  • Signal-channel complement
    16 fixed digital outputs, 8 configurable digital I/O, 4 analog inputs and 2 analog outputs
  • Terminal-unit requirement
    TU515 or TU516
  • Process voltage
    24 V DC; -15% / +20%; maximum 5% ripple
  • Process-supply consumption
    0.07 A plus maximum 0.5 A per digital output
  • Inrush integral at UP
    0.04 A2s at power-up
  • Unloaded module dissipation
    Maximum 6 W
  • Digital output current limits
    500 mA per channel; fixed DO0-DO15 bank maximum 4 A; DC16-DC23 bank maximum 4 A before derating
  • Digital off-state leakage
    Less than 0.5 mA
  • Digital output load switching
    Inductive loads: maximum 0.5 Hz; lamps: maximum 11 Hz at maximum 5 W
  • Configurable input characteristic
    IEC 61131-2 Type 1; 0.1-32 ms selectable filter
  • Fast-counter frequency
    Maximum 50 kHz; unavailable with a CS31 bus module
  • Analog input selections
    0-10 V, -10 to +10 V, 0-20 mA, 4-20 mA, Pt100, Pt1000 or Ni1000
  • Analog input impedance
    Voltage: greater than 100 kohm; current: approximately 330 ohm
  • Analog output selections
    -10 to +10 V, 0-20 mA or 4-20 mA; 12-bit resolution including sign
  • Analog receiver load
    Current output: 0-500 ohm; voltage output: maximum +/-10 mA
View all additional

Alternative Names

DA502 1SAP250800R0001 DA502 mixed signal output
SYSTEM & REPLACEMENT CHECK

Information needed before ordering

Three direct checks to secure your system integration and minimize ordering risks.

Information

System integration Replacement check Manuals & support
OUTPUT-ORIENTED MIXED I/O

Match output banks, analog circuits and controller settings

ABB DA502 combines sixteen fixed transistor outputs with eight configurable digital input/output channels, four analog inputs and two analog outputs. This S500 module supports output-oriented field stations that also need electrical or temperature measurements.
The fixed DO0-DO15 bank and configurable DC16-DC23 bank have separate documented current limits. Do not assume all fixed outputs can simultaneously supply their individual maximum rating.
Record voltage or current selection and the associated reference terminal for every analog channel. Preserve configured digital directions and confirm that the required fast-counter function is supported by the host arrangement.

Features:

  • Match standard order 1SAP250800R0001
  • Calculate the actual output-bank loading
  • Verify analog references and configured ranges
The ABB DA502 requires an output-bank load calculation and an explicit mixed-signal wiring schedule before system integration and commissioning.
INTERCHANGEABILITY

Verify the complete replacement identity before commissioning

ABB identifies standard DA502 order 1SAP250800R0001 as Active in datasheet revision 14 dated 2025-11-28. The separately ordered XC version must not be substituted solely on the basis of its similar name.
Record the terminal unit, fixed-output wiring, configurable digital directions, analog settings and controller project before replacement. The sixteen fixed outputs make DA502 different from a mixed-I/O module with fixed input banks.
Perform replacement with voltages isolated. Check protection, natural convection and mounting derating, then validate commanded loads and measured feedback before releasing the system.

Features:

  • Verify the standard DA502 order identity
  • Preserve fixed-output and configurable-bank assignments
  • Test load commands and analog feedback after exchange
The ABB DA502 requires replacement verification of its output architecture, analog configuration and installation conditions before commissioning.
DOCUMENTATION STATUS

Browse the Manuals, Datasheets, Official Documents, Links

Important Notice: These Amikon documents identify the exact ABB source edition. Terminal units, field devices and accessories are supplied only when expressly listed in the quotation.

Features:

  • DA502 documentation distinguishes fixed outputs from configurable channels
  • Software licensing and project backups remain the customer's responsibility
  • Accessories are supplied only when listed in the quotation
Documentation for the ABB DA502 must match the required output-bank arrangement and analog circuits; confirm manual availability in the written quotation.

Important notice

Manuals, software, firmware, cables, calibration data and accessories are included only when listed in the quotation. AMIKON is an independent supplier and is not affiliated with or authorised by the manufacturer.
This content has been produced using multiple sources. Takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
BUYER INFORMATION

Commercial terms without hidden steps

Your written quote confirms the product identity, price, availability, lead time, warranty and shipping terms before payment.
  • 01

    Shipping & delivery

    Dispatch
    Eligible stock: same / next day
    Carriers
    DHL, FedEx or UPS
    Ship from
    Xiamen, China
    Packed size
    13.4 × 7.3 × 4.3 cm
    Shipping weight
    0.16 kg
  • 02

    Payment & customs

    Payment
    Bank transfer (T/T)
    Currencies
    USD · EUR · GBP · RMB
    Credit cards
    Not accepted
    HS reference
    8538900000
    Origin
    Switzerland
  • 03

    Warranty & returns

    Warranty
    12 months from AMIKON
    Inspection
    Label, condition and packing checks
    Returns
    Prior RMA authorisation required
    Compatibility
    Confirm before order
    OEM warranty
    Does not apply
Your written quote confirms the product identity, price, availability, lead time, warranty and shipping terms before payment.
  • Part checked

    Full suffix recorded
  • Condition checked

    Label and appearance
  • Packing checked

    Antistatic protection
  • Tracking supplied

    Established couriers
  • Sandy Lin

    Dedicated account manager · 15+ years
FREQUENTLY ASKED QUESTIONS

Questions buyers ask about DA502

Direct answers about identity, compatibility, stock, warranty, payment and shipping.
  • Can all sixteen fixed DA502 outputs deliver 500 mA at the same time?

    No. Although each channel is rated 500 mA at 24 V, ABB limits the DO0-DO15 bank to 4 A total before applicable derating. Sixteen loads at 500 mA would exceed that bank limit.
  • Would replacing DA501 with DA502 preserve the first two digital terminal banks?

    No. DA502 has sixteen fixed outputs where DA501 has sixteen fixed inputs. Review the complete hardware and wiring design; a similar mixed-I/O format is not evidence of interchangeability.
  • Does the DA502 bipolar voltage selection also provide a negative-current output range?

    No. ABB lists -10 to +10 V as the bipolar voltage range but only 0-20 mA and 4-20 mA for current output. Do not configure a receiving circuit on the assumption of a bipolar current source.
  • Should the 0.04 A2s power-up figure be entered as a continuous current demand?

    No. It is the specified inrush integral at UP during power-up. Use the separate consumption figure, 0.07 A plus connected digital output load, when evaluating steady operation.
  • Can a machine specification quote a guaranteed DA502 digital switching delay from this datasheet?

    Not from the listed table alone. ABB marks the digital output transition delay as on request. Obtain the required manufacturer timing information before committing to a machine-level delay guarantee.
  • Are the fixed DO0-DO15 channels convertible to inputs by changing the program?

    No. The documented software-configurable channels are DC16-DC23. DO0-DO15 are the fixed transistor-output bank and should remain assigned as outputs in the hardware design.
  • Will changing an analog input from voltage to current leave the source loading unchanged?

    No. ABB specifies more than 100 kohm for voltage input and approximately 330 ohm for current input. Check the connected source, wiring and range before changing the measurement mode.
  • Can the digital-input ripple cross the undefined band if its average voltage looks correct?

    The average alone is not the stated criterion. ABB requires low-state ripple to remain within -3 to +5 V and high-state ripple within +15 to +30 V for the configurable digital input. Assess the waveform at the field terminal.
READY TO VERIFY YOUR PART?

Get a DA502 quote with price, lead time and revision check.

Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, drives and servo motors, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: Amikon Limited sells new and surplus products and develops channels for purchasing such products. Amikon Limited is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because Amikon Limited is not an authorized distributor of this product, the Original Manufacturer's warranty does not apply. Amikon Limited is not an authorized distributor, dealer, or representative of the products displayed on this website. All product names, trademarks, brands, and logos used on this website are the property of their respective owners. The description, explanation, or sale of products with these names, trademarks, brands, and logos is for identification purposes only and is not intended to indicate any association with or authorization from any rights holder.
Product

Product Browsing History