Close Menu
Get Parts Quote
Name
Company *
WhatsApp / WeChat (For Faster Quote) *
Email *
Address
City
State / Province / Region
Zipcode
Country
Quantity *
Part Number *
Manufacturer
Preferred Condition
Additional Information
Cancel
In Stock
Fast Shipping Available
ABB SM560-S-FD-1
· Product image is representative; revision or series may vary. Contact us to request a specific version.
Ships by Friday, November 27

SM560-S-FD-1

Safety processor module

Shipping Information

  • For inventory products, we support same day shipping upon payment.
  • For urgent needs, we offer same-day shipping on most items for orders placed before 2:00 PM UTC+8 Simply mention your preferred next-day shipping when place the order, and your order will be prioritized to minimize downtime.
  • For indent items, typical turnaround is 1-3 weeks, depending on parts availability and scarcity.
Customs & Documentation
We prepare clear, order-specific documentation for every international shipment, including the commercial invoice, packing list and available product or compliance documents. Before dispatch, our logistics team confirms the consignee details, declared value, shipping terms and destination requirements with you. Tracking information is provided after shipment, helping your team prepare for import clearance with confidence.
Documents checked before dispatch · Shipment details confirmed · Global tracking provided
Payment
Payment is by bank wire only in RMB/CNY, GBP, EUR or USD. Amikon does not accept credit cards or provide credit terms. Cleared payment is required before shipment unless the written quotation expressly states otherwise.
Product Condition
Factory New These are new and current items that are procured directly from the manufacturer.
New In Sealed Package Parts are new. They have not been used and still have their original package seal intact.
New in Original Package These parts are new. The packages were not originally sealed by their original manufacturer.
Quantity
Mobile *
Country/Region *
E-mail *
Company
Content *
(gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Amikong please read our privacy policy.
  • 20+

    years in automation
  • ISO 9001

    certified quality system
  • 12 months

    amikon warranty
  • 2-hour reply

    from your account manager
  • Success Story

    solutions in action
PRODUCT DESCRIPTION

SM560-S-FD-1 Safety processor module

ABB SM560-S-FD-1 is an AC500-S safety CPU with 1.3 MB program memory, designed for the documented SIL 3 and PL e safety architecture. It operates alongside a compatible non-safety AC500 CPU and exchanges safety data using PROFIsafe.

This F-Device variant adds connectivity to 1 PROFIsafe network while retaining F-Host capability. Its 1.3 MB program memory, safety I/O limits and compatible non-safety CPU firmware must be considered together when configuring the safety project.
ACTUAL APPLICATIONS

Application fields for SM560-S-FD-1

ABB SM560-S-FD-1 is an AC500-S safety CPU with 1.3 MB program memory, designed for the documented SIL 3 and PL e safety architecture. It operates alongside a compatible non-safety AC500 CPU and exchanges safety data using PROFIsafe.
  • 01 · POWER GENERATION

    Renewable Electricity
    and Conventional Energy

    Solar electricity, wind energy and nuclear generationThermal electricity generation and renewable geothermal energy
  • 02 · METALS

    Mineral Mining and
    Nonferrous Metallurgy

    Ferrous mineral mining and secondary metallurgyNonferrous mineral mining and primary ferrous metallurgy
  • 03 · TRANSPORT

    Rail Transport
    and Road Mobility

    Passenger rail transport and rail freight logisticsRoad passenger mobility and road freight transport

Technical specifications for SM560-S-FD-1

  • Product Model
    SM560-S-FD-1
  • Product Parameters
    Safety processor module
  • In stock
    8 units
  • Manufacturer
    ABB
  • Safety integrity level
    SIL 3
  • Performance level
    PL e
  • User program memory
    1.3 MB
  • Integrated data memory
    1 MB
  • Saved-data capacity
    120 kB
  • Binary instruction time
    0.05 us
  • Word instruction time
    0.06 us
  • Floating-point instruction time
    0.5 us
  • Maximum local safety I/O modules
    10
  • Maximum local safety digital inputs
    160 at SIL2; 80 at SIL3
  • Maximum local safety digital outputs
    80 at SIL3
  • Maximum local safety analog inputs
    40 at SIL2; 20 at SIL3
  • Safety protocol
    PROFIsafe V2
  • F-Device network capacity
    1
  • Ingress protection
    IP20 in complete closed assembly
View all additional

Alternative Names

SM560-S-FD-1 AC500-S Safety processor module
SYSTEM & REPLACEMENT CHECK

Information needed before ordering

Three direct checks to secure your system integration and minimize ordering risks.

Information

System integration Replacement check Manuals & support
SYSTEM INTEGRATION

Integrate SM560-S-FD-1 within AC500-S

ABB SM560-S-FD-1 is an AC500-S safety CPU with 1.3 MB program memory, designed for the documented SIL 3 and PL e safety architecture. It operates alongside a compatible non-safety AC500 CPU and exchanges safety data using PROFIsafe.
This F-Device variant adds connectivity to 1 PROFIsafe network while retaining F-Host capability. Its 1.3 MB program memory, safety I/O limits and compatible non-safety CPU firmware must be considered together when configuring the safety project.
Mount the safety CPU in the prescribed position beside the non-safety CPU on their common terminal base. Use the compatible Automation Builder safety tools, CPU firmware and validated PROFIsafe addressing, and perform the required safety acceptance test before service.

Features:

  • Safety integrity level: SIL 3
  • Performance level: PL e
  • AC500-S
Use SM560-S-FD-1 only within the documented AC500-S arrangement and applicable installation instructions.
INTERCHANGEABILITY

Replace SM560-S-FD-1 within AC500-S

Preserve the exact SM560-S-FD-1 variant, safety project and approved hardware configuration. SM560-S and the FD-1/FD-4 versions have different F-Device capabilities and are not interchangeable solely because their housings match.
Use the prescribed safe shutdown, backup and replacement procedure. Restore the correct safety application, confirm firmware compatibility and keep the safety validation and acceptance-test records.
Verify the configured F-Host/F-Device relationships, safety I/O mapping, diagnostics and defined safe-state response before releasing the installation.

Features:

  • Safety integrity level: SIL 3
  • Performance level: PL e
  • AC500-S
Use SM560-S-FD-1 only within the documented AC500-S arrangement and applicable installation instructions.
DOCUMENTATION STATUS

Browse the Manuals, Datasheets, Official Documents, Links

Important Notice: The linked files are Amikong-hosted reference documents. Match their product identity and scope to the supplied assembly, and consult the applicable manufacturer instructions before use. Accessories and additional documents are included only when expressly listed in the quotation.

Features:

  • Exact-model technical data for SM560-S-FD-1
  • Document applicability checked against the complete identity
  • Directory links by subcategory and brand
Documentation for SM560-S-FD-1 must match the installed product identity and supplied configuration.

Important notice

Manuals, software, firmware, cables, calibration data and accessories are included only when listed in the quotation. AMIKON is an independent supplier and is not affiliated with or authorised by the manufacturer.
This content has been produced using multiple sources. Takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
BUYER INFORMATION

Commercial terms without hidden steps

Your written quote confirms the product identity, price, availability, lead time, warranty and shipping terms before payment.
  • 01

    Shipping & delivery

    Dispatch
    Eligible stock: same / next day
    Carriers
    DHL, FedEx or UPS
    Ship from
    Xiamen, China
    Product size
    2.80 x 13.50 x 7.50 cm
    Net weight
    0.09 kg
  • 02

    Payment & customs

    Payment
    Bank transfer (T/T)
    Currencies
    USD · EUR · GBP · RMB
    Credit cards
    Not accepted
    HS reference
    85371091
    Origin
    Switzerland
  • 03

    Warranty & returns

    Warranty
    12 months from AMIKON
    Inspection
    Label, condition and packing checks
    Returns
    Prior RMA authorisation required
    Compatibility
    Confirm before order
    OEM warranty
    Does not apply
Your written quote confirms the product identity, price, availability, lead time, warranty and shipping terms before payment.
  • Part checked

    Full suffix recorded
  • Condition checked

    Label and appearance
  • Packing checked

    Antistatic protection
  • Tracking supplied

    Established couriers
  • Sandy Lin

    Dedicated account manager · 15+ years
FREQUENTLY ASKED QUESTIONS

Questions buyers ask about SM560-S-FD-1

Direct answers about identity, compatibility, stock, warranty, payment and shipping.
  • How many F-Device networks can SM560-S-FD-1 connect?

    SM560-S-FD-1 is listed for one F-Device network. Confirm that the intended integration fits that single-network capability; the FD-4 variant has a different network allowance.
  • What local digital-input limits apply to SM560-S-FD-1 at different safety levels?

    The stated SM560-S-FD-1 limits are 160 local safety digital inputs at SIL2 or 80 at SIL3. Apply the limit corresponding to the intended safety configuration instead of treating both figures as simultaneously available capacities.
  • How much program space is stated for the FD-1 safety project?

    SM560-S-FD-1 provides 1.3 MB user program memory, with 1 MB integrated data memory. Check the compiled safety project against its respective allocations before accepting a replacement configuration.
  • When is the SM560-S-FD-1 IP20 rating achieved?

    The specified IP20 protection applies to the complete closed assembly. Inspect the SM560-S-FD-1 installation accordingly rather than assigning that protection to an incomplete or open arrangement.
  • Which execution figure applies to binary instructions on SM560-S-FD-1?

    The SM560-S-FD-1 table states 0.05 us per binary instruction. This is an instruction execution figure, not the total safety response time of a configured function with I/O and communication.
  • Does the SM560-S-FD-1 PL e rating remove the need for safety-function validation?

    No. The documented SM560-S-FD-1 capability includes PL e and SIL 3, but the complete function and installed configuration still require the applicable safety validation. A component capability is not a substitute for that assessment.
  • What FD-1 detail should a distributor preserve when an RFQ says only SM560-S?

    Ask whether one F-Device network is required and retain the full SM560-S-FD-1 designation when it is. The standard SM560-S has a different functional scope, so an abbreviated order can select the wrong variant.
  • Which SM560-S-FD-1 configuration details should be agreed before a spare is shipped?

    Record the FD-1 article and revision, companion CPU, required single F-Device connection and supplied terminal/base scope. Confirm any engineering or software requirements separately so the quoted hardware is not mistaken for a ready-validated safety project.
READY TO VERIFY YOUR PART?

Get a SM560-S-FD-1 quote with price, lead time and revision check.

Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, drives and servo motors, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: Amikon Limited sells new and surplus products and develops channels for purchasing such products. Amikon Limited is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because Amikon Limited is not an authorized distributor of this product, the Original Manufacturer's warranty does not apply. Amikon Limited is not an authorized distributor, dealer, or representative of the products displayed on this website. All product names, trademarks, brands, and logos used on this website are the property of their respective owners. The description, explanation, or sale of products with these names, trademarks, brands, and logos is for identification purposes only and is not intended to indicate any association with or authorization from any rights holder.
Product

Product Browsing History