ABB CI873K01
· Product image is representative; revision or series may vary. Contact us to request a specific version.
Ships by Friday, November 27

CI873K01

Fieldbus interface kit

Shipping Information

  • For inventory products, we support same day shipping upon payment.
  • For urgent needs, we offer same-day shipping on most items for orders placed before 2:00 PM UTC+8 Simply mention your preferred next-day shipping when place the order, and your order will be prioritized to minimize downtime.
  • For indent items, typical turnaround is 1-3 weeks, depending on parts availability and scarcity.
Customs & Documentation
We prepare clear, order-specific documentation for every international shipment, including the commercial invoice, packing list and available product or compliance documents. Before dispatch, our logistics team confirms the consignee details, declared value, shipping terms and destination requirements with you. Tracking information is provided after shipment, helping your team prepare for import clearance with confidence.
Documents checked before dispatch · Shipment details confirmed · Global tracking provided
Payment
Payment is by bank wire only in RMB/CNY, GBP, EUR or USD. Amikon does not accept credit cards or provide credit terms. Cleared payment is required before shipment unless the written quotation expressly states otherwise.
Product Condition
Factory New These are new and current items that are procured directly from the manufacturer.
New In Sealed Package Parts are new. They have not been used and still have their original package seal intact.
New in Original Package These parts are new. The packages were not originally sealed by their original manufacturer.
Quantity
Mobile *
Country/Region *
E-mail *
Company
Content *
(gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Amikong please read our privacy policy.
  • 20+

    years in automation
  • ISO 9001

    certified quality system
  • 12 months

    amikon warranty
  • 2-hour reply

    from your account manager
  • Success Story

    solutions in action
PRODUCT DESCRIPTION

CI873K01 Fieldbus interface kit

ABB CI873K01 is an AC 800M communication interface kit for EtherNet/IP, supplied with the TP867 baseplate. It transfers process communication between the controller CEX-Bus and the corresponding external network.

The TP867 baseplate provides two RJ45 positions, but this interface uses only CH1 for 10/100 Mbit/s EtherNet/IP traffic. The unit takes power through the CEX-Bus and provides separate run, fault and traffic indicators.
ACTUAL APPLICATIONS

Application fields for CI873K01

ABB CI873K01 is an AC 800M communication interface kit for EtherNet/IP, supplied with the TP867 baseplate. It transfers process communication between the controller CEX-Bus and the corresponding external network.
  • 01 · OIL & GAS

    Inland Petroleum
    and Offshore Gas

    Inland petroleum and coastal gas energyOffshore natural gas and marine petroleum
  • 02 · MARINE

    Port Transport and
    Maritime Logistics

    Port freight transport and coastal cargo logisticsMaritime passenger logistics and inland port transport
  • 03 · PULP & PAPER

    Pulp, Paper and
    Publication Printing

    Pulp, paper and print publishingCommercial publication printing and graphic communication

Technical specifications for CI873K01

  • Product Model
    CI873K01
  • Product Parameters
    Fieldbus interface kit
  • In stock
    7 units
  • Manufacturer
    ABB
  • Network protocol
    EtherNet/IP
  • Ethernet line rate
    10 or 100 Mbit/s
  • Active network channel
    CH1
  • Ethernet connector
    RJ45
  • CEX supply voltage
    24 V DC
  • Supply current
    160 mA typical; 250 mA maximum
  • Power dissipation
    3.8 W typical; 6 W maximum
  • Ingress protection
    IP20
  • Processor
    MPC862P
  • Processor clock
    96 MHz
  • Ethernet standard
    IEEE 802.3u 10/100 Base-TX
  • Baseplate coding
    Mechanical code lock
  • Run indication
    Green LED
  • Fault indication
    Red LED
  • Traffic indication
    Flashing yellow RxTx1 LED
View all additional

Alternative Names

CI873K01 AC 800M EtherNet/IP Fieldbus interface kit
SYSTEM & REPLACEMENT CHECK

Information needed before ordering

Three direct checks to secure your system integration and minimize ordering risks.

Information

System integration Replacement check Manuals & support
SYSTEM INTEGRATION

Integrate CI873K01 within AC 800M EtherNet/IP

Install the TP867 baseplate with its mechanical code lock matched to the CI873K01 interface. Provide the CEX-Bus power and protective grounding specified by the controller hardware manual.
Connect EtherNet/IP through CH1 and an Ethernet switch. CH2 on this legacy interface is not an additional operational network port, despite the second RJ45 position on TP867.
Use the interface-specific engineering configuration and inspect run, fault and network indications after startup. Confirm data consistency and any configured failover behavior before returning the process to service.

Features:

  • Network protocol: EtherNet/IP
  • Ethernet line rate: 10 or 100 Mbit/s
  • AC 800M EtherNet/IP
Use CI873K01 only within the documented AC 800M EtherNet/IP arrangement and applicable installation instructions.
INTERCHANGEABILITY

Replace CI873K01 within AC 800M EtherNet/IP

Check the complete CI873K01 identifier and TP867 baseplate before removal. An A-suffixed successor or a different protocol interface must not be treated as automatically interchangeable.
Preserve the EtherNet/IP device and network configuration. Restore the network cable to CH1 and retain the original port allocation rather than assuming both baseplate sockets are active.
After exchange, verify the CEX-Bus recognition, interface diagnostics and actual field data. Perform the documented functional and recovery checks for the installed controller release.

Features:

  • Network protocol: EtherNet/IP
  • Ethernet line rate: 10 or 100 Mbit/s
  • AC 800M EtherNet/IP
Use CI873K01 only within the documented AC 800M EtherNet/IP arrangement and applicable installation instructions.
DOCUMENTATION STATUS

Browse the Manuals, Datasheets, Official Documents, Links

Important Notice: The linked files are Amikong-hosted reference documents. Match their product identity and scope to the supplied assembly, and consult the applicable manufacturer instructions before use. Accessories and additional documents are included only when expressly listed in the quotation.

Features:

  • Exact-model technical data for CI873K01
  • Document applicability checked against the complete identity
  • Directory links by subcategory and brand
Documentation for CI873K01 must match the installed product identity and supplied configuration.

Important notice

Manuals, software, firmware, cables, calibration data and accessories are included only when listed in the quotation. AMIKON is an independent supplier and is not affiliated with or authorised by the manufacturer.
This content has been produced using multiple sources. Takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
BUYER INFORMATION

Commercial terms without hidden steps

Your written quote confirms the product identity, price, availability, lead time, warranty and shipping terms before payment.
  • 01

    Shipping & delivery

    Dispatch
    Eligible stock: same / next day
    Carriers
    DHL, FedEx or UPS
    Ship from
    Xiamen, China
    Product size
    5.90 x 18.50 x 12.75 cm
    Net weight
    0.50 kg
  • 02

    Payment & customs

    Payment
    Bank transfer (T/T)
    Currencies
    USD · EUR · GBP · RMB
    Credit cards
    Not accepted
    HS reference
    85389099
    Origin
    Switzerland
  • 03

    Warranty & returns

    Warranty
    12 months from AMIKON
    Inspection
    Label, condition and packing checks
    Returns
    Prior RMA authorisation required
    Compatibility
    Confirm before order
    OEM warranty
    Does not apply
Your written quote confirms the product identity, price, availability, lead time, warranty and shipping terms before payment.
  • Part checked

    Full suffix recorded
  • Condition checked

    Label and appearance
  • Packing checked

    Antistatic protection
  • Tracking supplied

    Established couriers
  • Sandy Lin

    Dedicated account manager · 15+ years
FREQUENTLY ASKED QUESTIONS

Questions buyers ask about CI873K01

Direct answers about identity, compatibility, stock, warranty, payment and shipping.
  • Is the second TP867 socket available for CI873K01 network redundancy?

    The documented legacy CI873K01 arrangement uses CH1; CH2 is disabled. Two visible baseplate sockets therefore do not establish two usable EtherNet/IP links or a redundant network connection.
  • What protocol check separates CI873K01 from the similarly mounted CI871K01?

    CI873K01 is the EtherNet/IP interface, while CI871K01 is for PROFINET IO. Check the installed controller project and network protocol before considering an interface with the same TP867 baseplate.
  • Which CI873K01 Ethernet specification should be used for a replacement network connection?

    The manual lists IEEE 802.3u 10/100 Base-TX with an RJ45 connector for CI873K01. Preserve the documented physical connection and supported 10 or 100 Mbit/s rate when checking the replacement link.
  • Does the CI873K01 red Fault LED identify a particular failed component?

    The red LED is the CI873K01 fault indication; it does not by itself identify a failed component. Record the Run and traffic states as well and use the applicable controller diagnostics to investigate the reported condition.
  • What processor details identify the documented CI873 interface hardware?

    CI873K01 is documented with an MPC862P processor running at 96 MHz. Those are identification details for the interface hardware, not a basis for substituting a different communication protocol.
  • What does CI873K01 IP20 mean for a cabinet maintenance check?

    CI873K01 is specified as IP20. Inspect the surrounding enclosure and installation conditions accordingly; the interface housing should not be treated as protection against water exposure or an open outdoor installation.
  • What must an EtherNet/IP distributor quotation state for CI873K01?

    Name the complete CI873K01 kit and TP867 baseplate scope, with the offered article and revision. A PROFINET interface or a bare communication module should not be represented as the same supplied assembly.
  • Which CI873K01 details should be reconciled before accepting a delivered spare?

    Compare the CI873K01 label, controller-release requirement, TP867 coding and supplied baseplate with the purchase record. Inspect CH1 and connector condition before putting the spare into the EtherNet/IP installation.
READY TO VERIFY YOUR PART?

Get a CI873K01 quote with price, lead time and revision check.

Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, drives and servo motors, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: Amikon Limited sells new and surplus products and develops channels for purchasing such products. Amikon Limited is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because Amikon Limited is not an authorized distributor of this product, the Original Manufacturer's warranty does not apply. Amikon Limited is not an authorized distributor, dealer, or representative of the products displayed on this website. All product names, trademarks, brands, and logos used on this website are the property of their respective owners. The description, explanation, or sale of products with these names, trademarks, brands, and logos is for identification purposes only and is not intended to indicate any association with or authorization from any rights holder.
Product

Product Browsing History