ABB ICSI16E1
ABB ICSI16E1
ABB ICSI16E1
ABB ICSI16E1
ABB ICSI16E1
ABB ICSI16E1
· Product image is representative; revision or series may vary. Contact us to request a specific version.
Ships by Saturday, November 14

ICSI16E1

Isolated Digital Input Unit

Shipping Information

  • For inventory products, we support same day shipping upon payment.
  • For urgent needs, we offer same-day shipping on most items for orders placed before 2:00 PM UTC+8 Simply mention your preferred next-day shipping when place the order, and your order will be prioritized to minimize downtime.
  • For indent items, typical turnaround is 1-3 weeks, depending on parts availability and scarcity.
Customs & Documentation
We prepare clear, order-specific documentation for every international shipment, including the commercial invoice, packing list and available product or compliance documents. Before dispatch, our logistics team confirms the consignee details, declared value, shipping terms and destination requirements with you. Tracking information is provided after shipment, helping your team prepare for import clearance with confidence.
Documents checked before dispatch · Shipment details confirmed · Global tracking provided
Payment
Payment is by bank wire only in RMB/CNY, GBP, EUR or USD. Amikon does not accept credit cards or provide credit terms. Cleared payment is required before shipment unless the written quotation expressly states otherwise.
Product Condition
Factory New These are new and current items that are procured directly from the manufacturer.
New In Sealed Package Parts are new. They have not been used and still have their original package seal intact.
New in Original Package These parts are new. The packages were not originally sealed by their original manufacturer.
Quantity
Mobile *
Country/Region *
E-mail *
Company
Content *
(gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Amikong please read our privacy policy.
  • 20+

    years in automation
  • ISO 9001

    certified quality system
  • 12 months

    amikon warranty
  • 2-hour reply

    from your account manager
  • Success Story

    solutions in action
PRODUCT DESCRIPTION

ICSI16E1 Isolated Digital Input Unit

ABB ICSI16E1 is a CS31 isolated digital input unit with sixteen 24 V DC signal inputs. Each input draws 6 mA at 24 V DC and has a 1500 V AC optoisolation rating. The OFF range is -3 to +5 V DC and the ON range is +15 to +30 V DC.

The nominal input delay is 8 ms, with an effective value of 13 ms stated in the connection reference. Supply versions are separate: 24 V DC, 120 V AC and 230 V AC. These are unit power-supply selections, not alternate input-signal voltages. DC and AC versions also have different supply consumption and power-dissipation limits.
ACTUAL APPLICATIONS

Application fields for ICSI16E1

These broad application fields reflect the documented function and technical characteristics of ICSI16E1.
  • 01 · OIL & GAS

    Offshore Hydrocarbons and Conventional Petroleum Resources

    Conventional hydrocarbon resources and offshore gas reservesPetroleum condensate reserves and onshore natural gas
  • 02 · POWER GENERATION

    Conventional Electricity and Renewable Power Resources

    Conventional electricity fields and renewable power generationHydroelectric resource fields and alternative electricity generation
  • 03 · CHEMICALS

    Organic Chemicals and Inorganic Chemical Resources

    Organic chemical fields and inorganic resource areasSpecialty chemistry resources and basic petrochemical areas

Technical specifications for ICSI16E1

  • Product Model
    ICSI16E1
  • Product Parameters
    Isolated Digital Input Unit
  • In stock
    1 unit
  • Manufacturer
    ABB
  • Digital input channels
    16
  • Nominal input voltage
    24 V DC
  • Input OFF signal range
    -3 to +5 V DC
  • Input ON signal range
    +15 to +30 V DC
  • Input current at 24 V DC
    6 mA
  • Input optoisolation rating
    1500 V AC
  • Nominal input delay
    8 ms
  • Effective input delay
    13 ms
  • Open-circuit detection
    None
  • DC-powered variant supply
    24 V DC
  • AC-powered variant supply
    120 or 230 V AC, 50/60 Hz
  • Maximum DC-variant supply current
    0.2 A
  • Maximum AC-variant apparent power
    10 VA
  • Maximum DC-variant power dissipation
    4.5 W
  • Maximum AC-variant power dissipation
    8 W
View all additional

Alternative Names

ICSI16E1 ABB CS31 Isolated Digital Input Unit
SYSTEM & REPLACEMENT CHECK

Information needed before ordering

Three direct checks to secure your system integration and minimize ordering risks.

Information

System integration Replacement check Manuals & support
SYSTEM INTEGRATION

Integrate ICSI16E1 within ABB CS31

Connect ICSI16E1 to the documented CS31 arrangement with sixteen 24 V DC input signals. The 120 V AC and 230 V AC unit references describe power-supply variants; they do not change the nominal field-input signal from 24 V DC.
Retain the existing channel identification and field-circuit reference arrangement. The ABB migration document presents a later ICMK/XI16E1 arrangement separately, so its terminal layout and electrical limits must not be assumed to be those of the original unit.
Use the applicable original installation record for addressing and terminal assignments. Where a migration is proposed, review the complete replacement configuration and wiring changes rather than treating the new combination as a direct mechanical substitute.

Features:

  • Digital input channels: 16
  • Documented voltage variants: 24 V DC / 120 V AC / 230 V AC; reference-dependent
  • ABB CS31
Use ICSI16E1 only within the documented ABB CS31 arrangement and applicable installation instructions.
INTERCHANGEABILITY

Replace ICSI16E1 within ABB CS31

Record ICSI16E1, its ABB reference and the installed I/O arrangement before removal. Confirm sixteen inputs and the voltage selection on the complete unit reference, while keeping any proposed newer-module conversion separate from a like-for-like spare request.
Label all input conductors and preserve the isolation and reference arrangement during the exchange. Inspect the terminal connections and installation records instead of copying a terminal map from a later CS31 expansion product.
After the spare is connected, verify each affected input against the controller configuration and field state using the approved maintenance procedure. A migration to ICMK/XI16E1 needs its own configuration and wiring validation.

Features:

  • ICSI16E1 complete suffix
  • Input construction: Isolated binary inputs
  • Input variant and installed field wiring matched
Use ICSI16E1 only within the documented ABB CS31 arrangement and applicable installation instructions.
DOCUMENTATION STATUS

Browse the Manuals, Datasheets, Official Documents, Links

Important Notice: The linked files are Amikong-hosted reference documents. Match their product identity and scope to the supplied assembly, and consult the applicable manufacturer instructions before use. Accessories and additional documents are included only when expressly listed in the quotation.

Features:

  • Exact-model technical data for ICSI16E1
  • Document applicability checked against the complete identity
  • Directory links by subcategory and brand
Documentation for ICSI16E1 must match the installed product identity and supplied configuration.

Important notice

Manuals, software, firmware, cables, calibration data and accessories are included only when listed in the quotation. AMIKON is an independent supplier and is not affiliated with or authorised by the manufacturer.
This content has been produced using multiple sources. Takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
BUYER INFORMATION

Commercial terms without hidden steps

Your written quote confirms the product identity, price, availability, lead time, warranty and shipping terms before payment.
  • 01

    Shipping & delivery

    Dispatch
    Eligible stock: same / next day
    Carriers
    DHL, FedEx or UPS
    Ship from
    Xiamen, China
    Product size
    12.20 x 9.40 x 6.30 cm
    Net weight
    0.26 kg
  • 02

    Payment & customs

    Payment
    Bank transfer (T/T)
    Currencies
    USD · EUR · GBP · RMB
    Credit cards
    Not accepted
    HS reference
    8538900000
    Origin
    Switzerland
  • 03

    Warranty & returns

    Warranty
    12 months from AMIKON
    Inspection
    Label, condition and packing checks
    Returns
    Prior RMA authorisation required
    Compatibility
    Confirm before order
    OEM warranty
    Does not apply
Your written quote confirms the product identity, price, availability, lead time, warranty and shipping terms before payment.
  • Part checked

    Full suffix recorded
  • Condition checked

    Label and appearance
  • Packing checked

    Antistatic protection
  • Tracking supplied

    Established couriers
  • Sandy Lin

    Dedicated account manager · 15+ years
FREQUENTLY ASKED QUESTIONS

Questions buyers ask about ICSI16E1

Direct answers about identity, compatibility, stock, warranty, payment and shipping.
  • How many inputs are identified for ICSI16E1?

    The ABB technical guide identifies ICSI16E1 as a sixteen-channel binary input unit.
  • Are AC supply variants of ICSI16E1 AC signal-input units?

    No. ICSI16E1 has 24 V DC nominal field inputs. The 120 V AC and 230 V AC references identify unit power-supply variants; match the complete FPR reference to the supply.
  • Are the inputs of ICSI16E1 identified as isolated?

    Yes. The manufacturer description explicitly calls ICSI16E1 an isolated binary input unit.
  • Which power-supply references are documented for ICSI16E1?

    The ICSI16E1 supply references are FPR3316101R0032 for 24 V DC, FPR3316101R0036 for 230 V AC and FPR3316101R0034 for 120 V AC. The nominal input signal is 24 V DC for both AC-powered and DC-powered units.
  • Can XI16E1 specifications be copied to ICSI16E1?

    No. The guide presents a later ICMK/XI16E1 replacement arrangement separately from ICSI16E1; that does not make all specifications or wiring identical.
  • What should be recorded before removing ICSI16E1?

    Record the ICSI16E1 label, controller arrangement, addressing information and channel wiring so that the original I/O configuration can be restored.
  • How should a distributor separate a ICSI16E1 spare from a migration?

    Quote ICSI16E1 as the original unit when a like-for-like spare is requested. Identify any proposed ICMK/XI16E1 conversion and its extra components as a separate scope.
  • Which photos help confirm a ICSI16E1 order?

    Supply the ICSI16E1 marking, ABB reference and terminal photographs with quantity and required condition; the offer should state exactly which unit and accessories are supplied.
READY TO VERIFY YOUR PART?

Get a ICSI16E1 quote with price, lead time and revision check.

Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, drives and servo motors, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: Amikon Limited sells new and surplus products and develops channels for purchasing such products. Amikon Limited is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because Amikon Limited is not an authorized distributor of this product, the Original Manufacturer's warranty does not apply. Amikon Limited is not an authorized distributor, dealer, or representative of the products displayed on this website. All product names, trademarks, brands, and logos used on this website are the property of their respective owners. The description, explanation, or sale of products with these names, trademarks, brands, and logos is for identification purposes only and is not intended to indicate any association with or authorization from any rights holder.
Product