Product:X-Gateways
Data Rate:100 Mb/s
Number of Ports:2 x RJ45
Interface Type:Ethernet, USB
Supply Voltage - Min:24 V
Supply Voltage - Max:24 V
Packaging:Bulk
Brand:HMS Networks
Safetybus Power 0.85 load units
Number of Inputs 16, common power return
Vibration10 to 55 Hz: ±0.15mm
Turn-On Voltage (default) > 12 Vdc
Voltage: 15 to 80 VDC
Current:450 mA, maximum
Interface:RS-422/RS-485 (2 ports)
How connected:Multipoint
How communicates Half-duplex/Full-duplex
How synchronizes Start-stop synchronization
Transmission code ASCII/binary
Character length:7/8 bits
Stop bit :1/2 bits
Parity check None/even/odd
Transmission distance Maximum:1200 m
Current consumption:500 mA
Number of input channels:32
Rated input voltage:24 V DC
Input ON voltage:18 to 26.4 V DC
Input OFF voltage:5.0 V DC or less
Input current (at rated input voltage):4.1 mA±20 % / channel
Instantaneous allowable maximum input voltage:30.0 V DC
Input response time:8 ms or less
Minimum ON detection time:20 ms
Maximum ON/OFF cycle:25 Hz
Maximum current consumption:500 mA (5 V DC)
Number of input channels:8, isolated channels
Input frequency:0 to 10 kHz
Minimum input pulse width:40 μs
Shunt resistance Select from:OFF/200/500/1000 Ω
Pull-up resistance:68 kΩ (12 V DC or 24 V DC
Data refresh cycle:2 ms
Filter function Can select a filter that eliminates chattering
Transmitter power supply
Can select:24 V DC/12 V DC.
Number of output channels:64
Rated applied voltage:24 V DC
Load voltage:24 V DC, 100 mA
Field power supply voltagerange:20.4 to 26.4 V
Output ON voltage maximumvalue:2 V DC
Leak current maximum valuewhen output OFF:0.1 mA
Output format:Current sink
Number of input:channels16, non-isolated
Input signal:4 to 20 mA
Allowable input current/voltage:27 mA
Accuracy:±0.1% of full scale
Data refresh cycle:10 ms
Input step response time:100 ms
Transmitter power supply:22.8 to 26.4 V
Setting of 2-wire or 4-wiretransmitter
For each channel by setting pin
Allowable input voltage ±5 V.
Withstanding voltage :1500 V AC for 1minute
Power ON 2 MΩ or more
Power OFF 2 MΩ or more
Accuracy ±0.03% of full scale (for 0 to 400 Ω)
Allowable total resistance of signalsource plus wiring:40 Ω or less
(wiring resistance per wire)
Temperature drift:Max. ±30 ppm/°C.
Maximum current consumption:450 mA (5 V DC)
Outputs per module 2 channel single-ended, nonisolated
Output current 0…20 mA
Resolution 12 bits, 1/4096 max, 4.88 µA/bit
Converted data Binary data 0000 to 0fff (max scale)
Conversion time 2 ms/channel
Overall accuracy 0.2% Full scale @ 0…55 °C
Calibration None required
Allowable external output load resistance600 Ω max
Manufacturer: Alfa Laval
Model Number: 3183052091
Product Name: VCU-160 Module
Application: HVAC systems
Input Voltage: Typically 24V DC or 230V AC
Operating Temperature Range: -20°C to +55°C
Protection Rating: Typically IP20
Manufacturer: Alfa Laval
Model Number: 3183034171
Product Name: Heatpac Control Module
Application: HVAC systems
Input Voltage: Typically 24V DC or 230V AC
Operating Temperature Range: -20°C to +55°C
MICRONET SIMPLEX LV DISCRETE FTM
INPUT VOLTAGE RATING: 27.4 AMP 18-32 VDC
OUTPUT VOLTAGE RATING: 16 AMP 24VDC
POWER SUPPLY INPUT: (18 TO 32) V (DC)
SIGNAL TO ACTUATOR: 0 TO 200 MA
NETWORK ISOLATION: 0–60 HZ: 1000 VRMS
Input Voltage:Typically 24 VDC
Power Consumption:Around 25 W
Operating Temperature Range:Typically -20°C to 60°C
Storage Temperature Range:-40°C to 85°C.
Relative Humidity:5% to 95% non-condensing.
Input Voltage: Typically 24 V DC
Operating Temperature Range:
Typically -30°C to +70°C (-22°F to 158°F)
Storage Temperature Range:
-40°C to +85°C (-40°F to 185°F)