Power Supply Voltage:24 VDC nominal
Output Signal:4-20 mA
Frequency Response:10 Hz to 10 kHz (-3 dB)
Gain Accuracy:±1% of full scale
Operating Temperature:
-40°C to +85°C (-40°F to +185°F)
Storage Temperature:
-50°C to +90°C (-58°F to +194°F)
Power Supply Voltage:24 VDC nominal
Power Consumption:≤ 3 W
Analog Output:4-20 mA
Frequency Response:10 Hz to 1 kHz (-3 dB)
Operating Temperature:
-40°C to +85°C (-40°F to +185°F)
Storage Temperature:
-50°C to +90°C (-58°F to +194°F)
Power Supply Voltage:24 VDC nominal
Power Consumption:≤ 5 W
Analog Output:4-20 mA
Frequency Response:2 Hz to 10 kHz (-3 dB)
Operating Temperature:-20°C to +70°C (-4°F to +158°F)
Storage Temperature:-40°C to +85°C (-40°F to +185°F)
Power Supply Voltage:24 VDC nominal
Power Consumption:≤ 5 W
Analog Output:4-20 mA
Frequency Response:2 Hz to 10 kHz (-3 dB)
Operating Temperature:-20°C to +70°C (-4°F to +158°F)
Storage Temperature:-40°C to +85°C (-40°F to +185°F)
Power Supply Voltage:24 VDC (nominal), ±10%
Power Consumption:≤ 5 W
Current Output:4-20 mA
Frequency Response:0.5 Hz to 10 kHz (-3 dB)
Operating Temperature:
-20°C to +70°C (-4°F to +158°F)
Storage Temperature:
-40°C to +85°C (-40°F to +185°F)
Power Supply:Voltage: -23 to -30VDC
Sensitivity:3.94 mV/um (100mV/mil)
Linear Range:
4.0mm (160mils)
begins at 0.40mm (16mils)
fromprobe surface (AISI4140)
Range is 0.40 - 4.40mm (16 - 173 mils)
Frequency Response (±3db):0 - 3.0 kHz
Power Supply Voltage:
24 VDC (nominal), with ±10% tolerance
Power Consumption:≤ 10 W
Signal Input Channels:4 to 16 channels
Vibration: 4-20 mA or 0-5 VDC.
Proximity Probe: -24 VDC signal bias.
Temperature: RTD or Thermocouple
Power Supply: 3-phase 380-480V AC, 50/60 Hz
Output Voltage: Adjustable from 0 to input voltage
Output Frequency Range: 0 to 320 Hz
Rated Power: 22 kW
Current Rating: 47.5 A
Input Voltage Range:24 V DC or 110 V AC/DC
Relay Contacts:1 A to 5 A,
Operating Temperature Range:-20°C to +70°C
Storage Temperature Range:-40°C to +85°C
Input Voltage Range:24 V DC or 110 V AC/DC
Relay Contacts:1 A to 5 A,
Operating Temperature Range:-20°C to +70°C
Storage Temperature Range:-40°C to +85°C
Input Voltage Range: 24 V DC
Number of Inputs: 32 discrete inputs
Operating Voltage: 24 V DC
Operating Temperature: -20°C to +60°C
Storage Temperature: -40°C to +85°C
Humidity Range: Typically 5% to 95%
Input Voltage: 24V DC (nominal)
Power Consumption: Typically 10W
Operating Temperature: -15°C to +55°C
Storage Temperature: -40°C to +70°C
Humidity: 0 to 95% RH, non-condensing
Powermonitor 3000
Master Module with
3-Phase metering & setpoints & I/O
Data logging
5 Amps, Control Power
120V/240V AC 50/60- Hz or
125V/250V DC
Revenue metering
compliance to 1% Accuracy
I/O module:16 digital inputs 24 VDC in 4 groups
Status indicators:I/O function per channel
Operation:0 to 60°C
Storage:-25 to 70°C
Nominal voltage:24 VDC
Hardware:≤12 ms
Switchable displaysk
Text or bar graph displayk
8 limit comparatorsk
4 setpointsk
2 parameter setsk
Maths and logic modulek
Ramp and profile program function
Concept:Transparent Ready
Port Ethernet:10/100BASE-TX - 8 port(s) copper cable
Supply voltage limits:9.6…32 V DC SELV
Power consumption in W:6 W
Alarm output:1 voltfree contact 1 A
Ambient air temperature for operation:0…60 °C
rated supply voltage:12...24 V
Load cell supply 5 V alternating current supply
Input signal 0 15 mV
Sensitivity 0.6 μV / d
Unit kg, g, t, lb, N, kN
Linearity error <0.05 ‰ / 10 K