Close Menu
Get Parts Quote
Name
Company *
WhatsApp / WeChat (For Faster Quote) *
Email *
Address
City
State / Province / Region
Zipcode
Country
Quantity *
Part Number *
Manufacturer
Preferred Condition
Additional Information
Cancel
In Stock
Fast Shipping Available
Bently Nevada 330101-00-20-90-12-05
· Product image is representative; revision or series may vary. Contact us to request a specific version.
Ships by Thursday, September 17

330101-00-20-90-12-05

FluidLoc imperial proximity probe

Shipping Information

  • For inventory products, we support same day shipping upon payment.
  • For urgent needs, we offer same-day shipping on most items for orders placed before 2:00 PM UTC+8 Simply mention your preferred next-day shipping when place the order, and your order will be prioritized to minimize downtime.
  • For indent items, typical turnaround is 1-3 weeks, depending on parts availability and scarcity.
Customs & Documentation
We prepare clear, order-specific documentation for every international shipment, including the commercial invoice, packing list and available product or compliance documents. Before dispatch, our logistics team confirms the consignee details, declared value, shipping terms and destination requirements with you. Tracking information is provided after shipment, helping your team prepare for import clearance with confidence.
Documents checked before dispatch · Shipment details confirmed · Global tracking provided
Payment
Payment is by bank wire only in RMB/CNY, GBP, EUR or USD. Amikon does not accept credit cards or provide credit terms. Cleared payment is required before shipment unless the written quotation expressly states otherwise.
Product Condition
Factory New These are new and current items that are procured directly from the manufacturer.
New In Sealed Package Parts are new. They have not been used and still have their original package seal intact.
New in Original Package These parts are new. The packages were not originally sealed by their original manufacturer.
Quantity
Mobile *
Country/Region *
E-mail *
Company
Content *
(gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Amikong please read our privacy policy.
  • 20+

    years in automation
  • ISO 9001

    certified quality system
  • 12 months

    amikon warranty
  • 2-hour reply

    from your account manager
  • Success Story

    solutions in action
PRODUCT DESCRIPTION

FluidLoc imperial proximity probe

Bently Nevada 330101-00-20-90-12-05 combines a 2.0 inch standard mount case with nine meter FluidLoc cable in the 3300 XL 8 mm probe family. The unarmored assembly uses a 3/8-24 UNF thread and a miniature coaxial ClickLoc connector without a protector.

The probe measures distance to a conductive surface as part of the correctly configured transducer system. Its cable option restricts internal liquid migration, while connector protection and pressure containment require separate installation checks. Confirm the complete electrical length, target conditions and applicable hazardous area installation documentation.
ACTUAL APPLICATIONS

Documented probe application roles

The applications below describe the compatible manufacturer series. They do not establish installation of this exact order in a named factory or project.
  • 01 · VIBRATION

    FluidLoc vibration measurement channels

    Within the matched 3300 XL 8 mm system, this 9.0 meter probe senses dynamic shaft movement on fluid-film bearing machinery. Its 2.0 inch case must fit the measurement location; these are series applications, not evidence of a named project installation.
  • 02 · POSITION

    Machine position sensing chains

    The compatible system measures static distance from the probe tip to a conductive target. For this order, verify the 0.0 inch unthreaded section and 2.0 inch case against the mounting drawing before configuring the position channel.
  • 03 · ROTATIONAL REFERENCE

    Keyphasor signal collection

    The documented series supports Keyphasor reference and speed measurements from a suitable target. Match this 9.0 meter FluidLoc probe to the correct sensor and electrical length, and consult the manufacturer application note for tachometer or overspeed use.

Technical specifications for 330101-00-20-90-12-05

  • Product Model
    330101-00-20-90-12-05
  • Spare Model
    330101-00-20-90-12-05
  • Product Parameters
    FluidLoc imperial proximity probe
  • In stock
    1 unit
  • Manufacturer
    Bently Nevada
  • Mounting thread
    3/8-24 UNF-2A
  • Unthreaded length
    0.0 in
  • Overall case length
    2.0 in
  • Nominal total probe length
    9.0 m
  • Lead protection
    Without armor
  • Connector and cable
    ClickLoc; FluidLoc cable; no protector
  • Agency approval option
    05: CSA, ATEX and IECEx; check markings
  • Probe tip diameter
    8.0 mm
  • Probe tip material
    Polyphenylene sulfide (PPS)
  • Nominal probe DC resistance
    9.87 ohms, +/-0.50; center to outer
View all additional

Alternative Names

330101 00 20 90 12 05 330101-00-20-90-12-05 3300 XL 8 mm probe Bently Nevada 330101-00-20-90-12-05
SYSTEM & REPLACEMENT CHECK

Information needed before ordering

Three direct checks to secure your system integration and minimize ordering risks.

Information

System integration Replacement check Manuals & support
FLUIDLOC IMPERIAL PROXIMITY PROBE

Integrating 330101-00-20-90-12-05

Bently Nevada 330101-00-20-90-12-05 combines a 2.0 inch standard mount case with nine meter FluidLoc cable in the 3300 XL 8 mm probe family. The unarmored assembly uses a 3/8-24 UNF thread and a miniature coaxial ClickLoc connector without a protector.
The probe measures distance to a conductive surface as part of the correctly configured transducer system. Its cable option restricts internal liquid migration, while connector protection and pressure containment require separate installation checks. Confirm the complete electrical length, target conditions and applicable hazardous area installation documentation.
This configuration uses a 2.0 inch case, 0.0 inch unthreaded section and 9.0 meter probe length. FluidLoc limits liquid migration through the cable interior, not external leakage.

Features:

  • Match the 3300 XL 8 mm system
  • Respect the specified mounting geometry
  • Verify target and connector conditions
The 330101-00-20-90-12-05 fluidloc imperial proximity probe requires appropriate configuration before system integration and commissioning.
INTERCHANGEABILITY

Verify the complete replacement identity before commissioning

Compare the complete 330101-00-20-90-12-05 ordering code with the installed probe. Case length, unthreaded length, cable length, armor, connector option and approval selection must all match the documented installation.
The manufacturer permits specified interchangeability with non-XL 3300 five and eight millimeter components, but mixing XL and non-XL components limits performance to the non-XL specification. Mechanical fit and total electrical length remain essential.
No exact-order discontinuation date, hardware revision or designated successor was established in the reviewed manufacturer documentation. Datasheet revision AM is a publication revision, not a probe hardware revision or proof of a replacement designation.

Features:

  • Compare complete options before replacement
  • Check qualified family interchangeability
  • Do not infer a successor from appearance
The 330101-00-20-90-12-05 fluidloc imperial proximity probe requires replacement verification against the complete installed configuration and current manufacturer documentation.
DOCUMENTATION STATUS

Browse the Manuals, Datasheets, Official Documents, Links

Important Notice: The linked files are Amikong-hosted reference documents. Match their product identity and scope to the supplied assembly, and consult the applicable manufacturer instructions before use. Accessories and additional documents are included only when expressly listed in the quotation.

Features:

  • Verify document identity before procurement or installation
  • Match the complete order to the manufacturer document scope
  • Accessories are supplied only when listed in the quotation
Documentation for the 330101-00-20-90-12-05 fluidloc imperial proximity probe must be checked for document applicability before installation or commissioning.

Important notice

Manuals, software, firmware, cables, calibration data and accessories are included only when listed in the quotation. AMIKON is an independent supplier and is not affiliated with or authorised by the manufacturer.
This content has been produced using multiple sources. Takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
BUYER INFORMATION

Commercial terms without hidden steps

Your written quote confirms the product identity, price, availability, lead time, warranty and shipping terms before payment.
  • 01

    Shipping & delivery

    Dispatch
    Eligible stock: same / next day
    Carriers
    DHL, FedEx or UPS
    Ship from
    Xiamen, China
    Packed size
    Packed dimensions unconfirmed
    Shipping weight
    Gross weight unconfirmed
  • 02

    Payment & customs

    Payment
    Bank transfer (T/T)
    Currencies
    USD · EUR · GBP · RMB
    Credit cards
    Not accepted
    HS reference
    9031809090
    Origin
    USA
  • 03

    Warranty & returns

    Warranty
    12 months from AMIKON
    Inspection
    Label, condition and packing checks
    Returns
    Prior RMA authorisation required
    Compatibility
    Confirm before order
    OEM warranty
    Does not apply
Your written quote confirms the product identity, price, availability, lead time, warranty and shipping terms before payment.
  • Part checked

    Full suffix recorded
  • Condition checked

    Label and appearance
  • Packing checked

    Antistatic protection
  • Tracking supplied

    Established couriers
  • Sandy Lin

    Dedicated account manager · 15+ years
FREQUENTLY ASKED QUESTIONS

Questions buyers ask about 330101-00-20-90-12-05

Direct answers about identity, compatibility, stock, warranty, payment and shipping.
  • Is this a standard cable or FluidLoc cable probe?

    Connector and cable option 12 selects FluidLoc cable. It must not be described using the standard cable specification of option 02 merely because both use ClickLoc connectors.
  • What is the difference between case length and total length?

    For this order, 20 denotes a 2.0 inch case and 90 denotes a nine meter nominal total probe length. The first 00 field specifies zero unthreaded length.
  • Does this configuration include the connector protector?

    No. The protected FluidLoc option is 11; option 12 has the FluidLoc ClickLoc connection without the protector. The manufacturer recommends protection for the connection.
  • Will a five meter Proximitor match this integral cable?

    This order selects a nine meter probe length. Match it to the documented electrical-length system; a five meter sensor must not be assumed interchangeable solely because the connector fits.
  • What resistance check applies to the nine meter probe?

    The published nominal probe resistance between center and outer conductors is 9.87 ohms, plus or minus 0.50 ohm. Use the separate extension-cable table only when checking that different component.
  • Can it serve a rotational reference channel?

    The series supports Keyphasor reference and speed measurements with the appropriate target and monitor. The manufacturer specifically calls for its eddy-current probe application note when considering tachometer or overspeed use.
READY TO VERIFY YOUR PART?

Get a 330101-00-20-90-12-05 quote with price, lead time and revision check.

Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, drives and servo motors, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: Amikon Limited sells new and surplus products and develops channels for purchasing such products. Amikon Limited is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because Amikon Limited is not an authorized distributor of this product, the Original Manufacturer's warranty does not apply. Amikon Limited is not an authorized distributor, dealer, or representative of the products displayed on this website. All product names, trademarks, brands, and logos used on this website are the property of their respective owners. The description, explanation, or sale of products with these names, trademarks, brands, and logos is for identification purposes only and is not intended to indicate any association with or authorization from any rights holder.
Product

Product Browsing History