Bently Nevada 3500/46M 176449-06
· Product image is representative; revision or series may vary. Contact us to request a specific version.
Ships by Saturday, September 19

3500/46M 176449-06

Hydro turbine monitoring module

Shipping Information

  • For inventory products, we support same day shipping upon payment.
  • For urgent needs, we offer same-day shipping on most items for orders placed before 2:00 PM UTC+8 Simply mention your preferred next-day shipping when place the order, and your order will be prioritized to minimize downtime.
  • For indent items, typical turnaround is 1-3 weeks, depending on parts availability and scarcity.
Customs & Documentation
We prepare clear, order-specific documentation for every international shipment, including the commercial invoice, packing list and available product or compliance documents. Before dispatch, our logistics team confirms the consignee details, declared value, shipping terms and destination requirements with you. Tracking information is provided after shipment, helping your team prepare for import clearance with confidence.
Documents checked before dispatch · Shipment details confirmed · Global tracking provided
Payment
Payment is by bank wire only in RMB/CNY, GBP, EUR or USD. Amikon does not accept credit cards or provide credit terms. Cleared payment is required before shipment unless the written quotation expressly states otherwise.
Product Condition
Factory New These are new and current items that are procured directly from the manufacturer.
New In Sealed Package Parts are new. They have not been used and still have their original package seal intact.
New in Original Package These parts are new. The packages were not originally sealed by their original manufacturer.
Quantity
Mobile *
Country/Region *
E-mail *
Company
Content *
(gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Amikong please read our privacy policy.
  • 20+

    years in automation
  • ISO 9001

    certified quality system
  • 12 months

    amikon warranty
  • 2-hour reply

    from your account manager
  • Success Story

    solutions in action
PRODUCT DESCRIPTION

Hydro turbine monitoring module

Bently Nevada 3500/46M 176449-06 is a hydro monitoring module. The monitor processes signals used to supervise hydro turbine-generators. It supports configured vibration, position and pressure measurements with matching I/O. Mode-specific alarm settings can reflect changing operating conditions, but the Hydro Velocity function is not intended for automated machinery protection.

The official spare table identifies 176449-06 as the 3500/46M Hydro Monitor. Match the rear I/O, sensor system and selected measurement. The bare front-module identity does not confirm a supplied multimode I/O or delivered firmware revision.
ACTUAL APPLICATIONS

Applications for 3500/46M hydro monitoring system

These applications describe manufacturer-documented family use. They do not establish that this exact ordering code was installed at a named customer site.
  • 01 · HYDRO RADIAL VIBRATION

    Shaft movement and shear-pin monitoring

    Configured Hydro RV channels combine shaft-gap movement with NX amplitude for the documented composite indication. The measurement and operating speed must match the hydro machine.
  • 02 · GENERATOR AIR GAP

    Rotor-to-stator gap supervision

    Supported air-gap transducers provide pole-gap information for configured hydro channels. The monitor can report instantaneous, average and minimum gap as defined for that channel type.
  • 03 · OPERATING MODES

    Hydro alarms for changing conditions

    Multimode channels select among configured alarm sets through supported contacts or gateway commands. Hydro Velocity supplies diagnostic warning and must not be used for automated machinery protection.

Technical specifications for 3500/46M 176449-06

  • Product Model
    3500/46M 176449-06
  • Spare Model
    176449-06
  • Product Parameters
    Hydro turbine monitoring module
  • In stock
    10 units
  • Manufacturer
    Bently Nevada
  • Monitoring channels
    Four
  • Typical power consumption
    7.7 W
  • Supported measurements
    Hydro vibration, air gap, thrust, dynamic pressure and SEW with matching I/O
  • Mode-specific alarm sets
    Up to eight with supported multimode arrangement
  • Prox/Accel input impedance
    10 kohm with Prox/Velom I/O
  • Velomitor input impedance
    3.5 Mohm with Prox/Velom I/O
  • Buffered output impedance
    550 ohm
  • Recorder outputs
    4-20 mA per channel
  • Recorder load
    0-600 ohm
  • Recorder update
    100 ms or less
  • Front status indication
    OK, TX/RX and Bypass
  • Rack allocation
    One full-height front slot
View all additional

Alternative Names

3500/46M 176449 06 3500/46M 176449-06 hydro monitoring module Bently Nevada 3500/46M 176449-06
SYSTEM & REPLACEMENT CHECK

Information needed before ordering

Three direct checks to secure your system integration and minimize ordering risks.

Information

System integration Replacement check Manuals & support
HYDRO TURBINE MONITORING MODULE

Integrating 3500/46M 176449-06

The monitor processes signals used to supervise hydro turbine-generators. It supports configured vibration, position and pressure measurements with matching I/O. Mode-specific alarm settings can reflect changing operating conditions, but the Hydro Velocity function is not intended for automated machinery protection.
Hydro measurements have different minimum software and firmware versions. Hardware-contact multimode operation requires revision S multimode I/O; software switching requires the specified TDI and gateway versions. Hydro Dynamic Pressure requires monitor firmware 4.21 and Rack Configuration 5.20 or later.
Select the documented front monitor, rear I/O and transducer wiring. External-termination versions require separately ordered blocks and cables, while internal-termination I/O cannot use those blocks. Verify channel type, sensitivity, speed reference and required mode-change logic before commissioning.

Features:

  • Match monitor generation, matched front and rear assemblies, wiring and software
  • Follow the applicable installation instructions
  • Confirm unverified configuration details
The 3500/46M 176449-06 hydro monitoring module requires appropriate configuration before system integration and commissioning.
INTERCHANGEABILITY

Verify the complete replacement identity before commissioning

Replacement of 3500/46M 176449-06 requires comparing monitor generation, matched front and rear assemblies, wiring and software. A shared base family or similar appearance does not establish a drop-in replacement for the complete ordered assembly.
Hydro measurements have different minimum software and firmware versions. Hardware-contact multimode operation requires revision S multimode I/O; software switching requires the specified TDI and gateway versions. Hydro Dynamic Pressure requires monitor firmware 4.21 and Rack Configuration 5.20 or later.
No verified exact-order discontinuation date, product revision or designated successor is asserted. Document revisions identify the reference literature, not hardware changes to the supplied product. Unconfirmed replacement options must be resolved before substitution.

Features:

  • Preserve the complete ordering identity
  • Compare the installed electrical and mechanical interfaces
  • Do not infer hardware revisions or successor models
The 3500/46M 176449-06 hydro monitoring module requires replacement verification against the complete installed configuration and current manufacturer documentation.
DOCUMENTATION STATUS

Browse the Manuals, Datasheets, Official Documents, Links

Important Notice: No verified product PDF is currently available on this page. Amikong-hosted reference documents will be listed only after their product identity and scope have been checked. Consult the applicable manufacturer instructions before use; additional documents are included only when expressly listed in the quotation.

Features:

  • Verify document identity before procurement or installation
  • Match the complete order to the manufacturer document scope
  • Accessories are supplied only when listed in the quotation
Documentation for the 3500/46M 176449-06 hydro monitoring module must be checked for document applicability before installation or commissioning.

Important notice

Manuals, software, firmware, cables, calibration data and accessories are included only when listed in the quotation. AMIKON is an independent supplier and is not affiliated with or authorised by the manufacturer.
This content has been produced using multiple sources. Takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
BUYER INFORMATION

Commercial terms without hidden steps

Your written quote confirms the product identity, price, availability, lead time, warranty and shipping terms before payment.
  • 01

    Shipping & delivery

    Dispatch
    Eligible stock: same / next day
    Carriers
    DHL, FedEx or UPS
    Ship from
    Xiamen, China
    Packed size
    2.6cm x 25.8cm x 24cm
    Shipping weight
    0.8 kg
  • 02

    Payment & customs

    Payment
    Bank transfer (T/T)
    Currencies
    USD · EUR · GBP · RMB
    Credit cards
    Not accepted
    HS reference
    9031900090
    Origin
    USA
  • 03

    Warranty & returns

    Warranty
    12 months from AMIKON
    Inspection
    Label, condition and packing checks
    Returns
    Prior RMA authorisation required
    Compatibility
    Confirm before order
    OEM warranty
    Does not apply
Your written quote confirms the product identity, price, availability, lead time, warranty and shipping terms before payment.
  • Part checked

    Full suffix recorded
  • Condition checked

    Label and appearance
  • Packing checked

    Antistatic protection
  • Tracking supplied

    Established couriers
  • Sandy Lin

    Dedicated account manager · 15+ years
FREQUENTLY ASKED QUESTIONS

Questions buyers ask about 3500/46M 176449-06

Direct answers about identity, compatibility, stock, warranty, payment and shipping.
  • How is 3500/46M 176449-06 identified?

    The official spare table identifies 176449-06 as the 3500/46M Hydro Monitor. Match the rear I/O, sensor system and selected measurement. The bare front-module identity does not confirm a supplied multimode I/O or delivered firmware revision.
  • What is the function of this component?

    The monitor processes signals used to supervise hydro turbine-generators. It supports configured vibration, position and pressure measurements with matching I/O. Mode-specific alarm settings can reflect changing operating conditions, but the Hydro Velocity function is not intended for automated machinery protection.
  • Which installed equipment must be matched?

    Hydro measurements have different minimum software and firmware versions. Hardware-contact multimode operation requires revision S multimode I/O; software switching requires the specified TDI and gateway versions. Hydro Dynamic Pressure requires monitor firmware 4.21 and Rack Configuration 5.20 or later.
  • Where is this component used?

    Configured Hydro RV channels combine shaft-gap movement with NX amplitude for the documented composite indication. The measurement and operating speed must match the hydro machine.
  • What must be checked during installation?

    Select the documented front monitor, rear I/O and transducer wiring. External-termination versions require separately ordered blocks and cables, while internal-termination I/O cannot use those blocks. Verify channel type, sensitivity, speed reference and required mode-change logic before commissioning.
  • Can Hydro Velocity trip the machine automatically?

    No. The manufacturer explicitly excludes that channel type from automated machinery protection because of the nature of high-amplitude, low-frequency events. It is for early warning and diagnosis.
  • What is required for contact-driven multimode operation?

    The reviewed compatibility table requires revision S multimode I/O modules. The complete front-module, configuration software and channel requirements must also be satisfied; the stock part number alone does not prove the delivered revision.
READY TO VERIFY YOUR PART?

Get a 3500/46M 176449-06 quote with price, lead time and revision check.

Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, drives and servo motors, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: Amikon Limited sells new and surplus products and develops channels for purchasing such products. Amikon Limited is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because Amikon Limited is not an authorized distributor of this product, the Original Manufacturer's warranty does not apply. Amikon Limited is not an authorized distributor, dealer, or representative of the products displayed on this website. All product names, trademarks, brands, and logos used on this website are the property of their respective owners. The description, explanation, or sale of products with these names, trademarks, brands, and logos is for identification purposes only and is not intended to indicate any association with or authorization from any rights holder.