Close Menu
Get Parts Quote
Name
Company *
WhatsApp / WeChat (For Faster Quote) *
Email *
Address
City
State / Province / Region
Zipcode
Country
Quantity *
Part Number *
Manufacturer
Preferred Condition
Additional Information
Cancel
In Stock
Fast Shipping Available
Epro PR6423/015-000-CN CON021
Epro PR6423/015-000-CN CON021
Epro PR6423/015-000-CN CON021
Epro PR6423/015-000-CN CON021
Epro PR6423/015-000-CN CON021
Epro PR6423/015-000-CN CON021
· Product image is representative; revision or series may vary. Contact us to request a specific version.
Ships by Saturday, November 14

PR6423/015-000-CN CON021

Eddy-current displacement measuring assembly

Shipping Information

  • For inventory products, we support same day shipping upon payment.
  • For urgent needs, we offer same-day shipping on most items for orders placed before 2:00 PM UTC+8 Simply mention your preferred next-day shipping when place the order, and your order will be prioritized to minimize downtime.
  • For indent items, typical turnaround is 1-3 weeks, depending on parts availability and scarcity.
Customs & Documentation
We prepare clear, order-specific documentation for every international shipment, including the commercial invoice, packing list and available product or compliance documents. Before dispatch, our logistics team confirms the consignee details, declared value, shipping terms and destination requirements with you. Tracking information is provided after shipment, helping your team prepare for import clearance with confidence.
Documents checked before dispatch · Shipment details confirmed · Global tracking provided
Payment
Payment is by bank wire only in RMB/CNY, GBP, EUR or USD. Amikon does not accept credit cards or provide credit terms. Cleared payment is required before shipment unless the written quotation expressly states otherwise.
Product Condition
Factory New These are new and current items that are procured directly from the manufacturer.
New In Sealed Package Parts are new. They have not been used and still have their original package seal intact.
New in Original Package These parts are new. The packages were not originally sealed by their original manufacturer.
Quantity
Mobile *
Country/Region *
E-mail *
Company
Content *
(gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Amikong please read our privacy policy.
  • 20+

    years in automation
  • ISO 9001

    certified quality system
  • 12 months

    amikon warranty
  • 2-hour reply

    from your account manager
  • Success Story

    solutions in action
PRODUCT DESCRIPTION

PR6423/015-000-CN CON021 Eddy-current displacement measuring assembly

Epro PR6423/015-000-CN CON021 combines an eight-millimetre PR6423 eddy-current probe with a CON021 converter for non-contact shaft displacement measurement. The probe detects radial or axial movement, position and related shaft behavior without mechanical contact with the rotating target.

The 8 mm tip provides a nominal sensitivity of 8 V/mm and a 2 mm linear measuring range when used with the specified signal converter. The 75 mm threaded case has an M10 x 1 mounting thread and a four-metre armoured cable ending in a LEMO connection. The measurement is non-contact, with no mechanical loading of the shaft surface.
ACTUAL APPLICATIONS

Application fields for PR6423/015-000-CN CON021

These broad application fields reflect the documented function and technical characteristics of PR6423/015-000-CN CON021.
  • 01 · POWER GENERATION

    Thermal Power and Renewable Energy

    Regional electricity and renewable energy sectorsHydroelectric power and renewable energy sectors
  • 02 · OIL & GAS

    Petroleum Refining and Natural Gas

    Offshore petroleum and onshore natural gasPetroleum refining and natural gas sectors
  • 03 · METALS & MINING

    Industrial Metallurgy and Mineral Engineering

    Mineral extraction and nonferrous metallurgy sectorsIndustrial mining and extractive metallurgy sectors

Technical specifications for PR6423/015-000-CN CON021

  • Product Model
    PR6423/015-000-CN CON021
  • Spare Model
    PR6423/015-000-CN
  • Product Parameters
    Eddy-current displacement measuring assembly
  • In stock
    1 unit
  • Manufacturer
    Epro
  • Probe tip diameter
    8 mm
  • Case thread
    M10 x 1
  • Armoured cable
    Yes, PR6423/01 construction
  • Case length
    75 mm, code 5
  • Adapter plug
    Fitted, code 0
  • Nominal total cable length
    4.0 m, cable code 0
  • Cable termination
    Lemo connector, code 0
  • Linear measuring range
    2 mm
  • Initial air gap
    0.5 mm
  • Incremental scale factor
    8 V/mm ±5% at 0-45 °C
  • Deviation from straight line
    ±0.025 mm at 0-45 °C
  • Minimum target shaft diameter
    25 mm
  • Probe ingress protection
    IP66
  • Probe-tip material
    PEEK
  • Case material
    Stainless steel
View all additional

Alternative Names

PR6423/015-000-CN CON021 PR6423 / CON021 Eddy-current displacement measuring assembly
SYSTEM & REPLACEMENT CHECK

Information needed before ordering

Three direct checks to secure your system integration and minimize ordering risks.

Information

System integration Replacement check Manuals & support
SYSTEM INTEGRATION

Integrate PR6423/015-000-CN CON021 within PR6423 / CON021

Mount the PR6423 probe using the M10 x 1 threaded arrangement and set the initial gap against the intended target. The specified 2 mm span and 8 V/mm scale factor relate to the complete measuring-chain conditions and the stated ferromagnetic reference material.
Preserve the 75 mm case, armoured cable, adapter and Lemo arrangement when routing the PR6423/015-000 connection to CON021. Observe the cable bending limits and verify that the converter and total cable arrangement match the calibrated chain.
Check static gap voltage and the connected monitor scaling before the shaft is operated. Validate displacement response, signal direction and circuit health using the applicable converter and monitoring instructions; a sensor-family datasheet alone does not establish a hazardous-area installation approval.

Features:

  • Probe tip diameter: 8 mm
  • Case thread: M10 x 1
  • PR6423 / CON021
Use PR6423/015-000-CN CON021 only within the documented PR6423 / CON021 arrangement and applicable installation instructions.
INTERCHANGEABILITY

Replace PR6423/015-000-CN CON021 within PR6423 / CON021

Record the full PR6423/015-000-CN CON021 assembly, including the CN suffix, the probe cable arrangement and CON021 identification. A replacement probe with another case, connector or total cable selection changes the physical measuring-chain configuration.
Inspect the probe tip, armour, cable joint and converter connection while the machine is secured for service. Retain the installed gap reference and monitor configuration, and avoid mechanically forcing the probe against the target during fitting.
After replacement, check the static gap, displacement scaling and monitor fault indications through the full measuring chain. Use the approved dynamic verification method before releasing shaft monitoring or protection channels.

Features:

  • Probe tip diameter: 8 mm
  • Case thread: M10 x 1
  • PR6423 / CON021
Use PR6423/015-000-CN CON021 only within the documented PR6423 / CON021 arrangement and applicable installation instructions.
DOCUMENTATION STATUS

Browse the Manuals, Datasheets, Official Documents, Links

Important Notice: The linked files are Amikong-hosted reference documents. Match their product identity and scope to the supplied assembly, and consult the applicable manufacturer instructions before use. Accessories and additional documents are included only when expressly listed in the quotation.

Features:

  • Exact-model technical data for PR6423/015-000-CN CON021
  • Document applicability checked against the complete identity
  • Directory links by subcategory and brand
Documentation for PR6423/015-000-CN CON021 must match the installed product identity and supplied configuration.

Important notice

Manuals, software, firmware, cables, calibration data and accessories are included only when listed in the quotation. AMIKON is an independent supplier and is not affiliated with or authorised by the manufacturer.
This content has been produced using multiple sources. Takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
BUYER INFORMATION

Commercial terms without hidden steps

Your written quote confirms the product identity, price, availability, lead time, warranty and shipping terms before payment.
  • 01

    Shipping & delivery

    Dispatch
    Eligible stock: same / next day
    Carriers
    DHL, FedEx or UPS
    Ship from
    Xiamen, China
    Product size
    20.00 x 20.00 x 4.00 cm
    Net weight
    0.40 kg
  • 02

    Payment & customs

    Payment
    Bank transfer (T/T)
    Currencies
    USD · EUR · GBP · RMB
    Credit cards
    Not accepted
    HS reference
    9031809090
    Origin
    Germany
  • 03

    Warranty & returns

    Warranty
    12 months from AMIKON
    Inspection
    Label, condition and packing checks
    Returns
    Prior RMA authorisation required
    Compatibility
    Confirm before order
    OEM warranty
    Does not apply
Your written quote confirms the product identity, price, availability, lead time, warranty and shipping terms before payment.
  • Part checked

    Full suffix recorded
  • Condition checked

    Label and appearance
  • Packing checked

    Antistatic protection
  • Tracking supplied

    Established couriers
  • Sandy Lin

    Dedicated account manager · 15+ years
FREQUENTLY ASKED QUESTIONS

Questions buyers ask about PR6423/015-000-CN CON021

Direct answers about identity, compatibility, stock, warranty, payment and shipping.
  • What does the 015-000 probe selection specify (PR6423/015-000-CN CON021)?

    The ordering table gives M10 x 1, armoured cable, a 75 mm case, adapter plug, 4.0 m cable code and Lemo termination.
  • Does the CN suffix establish hazardous-area approval by itself (PR6423/015-000-CN CON021)?

    No. Keep the CN marking, but assess the actual probe, converter and supplied certification rather than inferring approval from that suffix.
  • What initial gap belongs to the PR6423 measuring span (PR6423/015-000-CN CON021)?

    The PR6423 datasheet gives a 0.5 mm initial air gap with a 2 mm linear measuring range.
  • Can a bare PR6423 probe deliver the finished monitor signal (PR6423/015-000-CN CON021)?

    The probe works as part of a matched chain with its cable and converter; this assembly includes CON021.
  • Which target material underlies the published sensitivity (PR6423/015-000-CN CON021)?

    The standard reference target is ferromagnetic 42CrMo4, identified as AISI/SAE 4140.
  • What must be checked after a CN-chain probe replacement (PR6423/015-000-CN CON021)?

    Check static gap, chain scaling and monitor diagnostics while retaining the actual CN-marked component arrangement.
  • What should procurement retain for the CN assembly order (PR6423/015-000-CN CON021)?

    Specify PR6423/015-000-CN CON021 in full and state whether probe, converter and connecting cable are required together.
  • What should receiving compare on a CN measuring-chain shipment (PR6423/015-000-CN CON021)?

    Compare the CN probe marking, case and cable construction, Lemo connection and CON021 label with the quoted scope.
READY TO VERIFY YOUR PART?

Get a PR6423/015-000-CN CON021 quote with price, lead time and revision check.

Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, drives and servo motors, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: Amikon Limited sells new and surplus products and develops channels for purchasing such products. Amikon Limited is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because Amikon Limited is not an authorized distributor of this product, the Original Manufacturer's warranty does not apply. Amikon Limited is not an authorized distributor, dealer, or representative of the products displayed on this website. All product names, trademarks, brands, and logos used on this website are the property of their respective owners. The description, explanation, or sale of products with these names, trademarks, brands, and logos is for identification purposes only and is not intended to indicate any association with or authorization from any rights holder.
Product