General Electric XMTC-62-11-0
General Electric XMTC-62-11-0
General Electric XMTC-62-11-0
General Electric XMTC-62-11-0
General Electric XMTC-62-11-0
General Electric XMTC-62-11-0
· Product image is representative; revision or series may vary. Contact us to request a specific version.
Ships by Sunday, October 18

XMTC-62-11-0

Thermal conductivity gas transmitter

Shipping Information

  • For inventory products, we support same day shipping upon payment.
  • For urgent needs, we offer same-day shipping on most items for orders placed before 2:00 PM UTC+8 Simply mention your preferred next-day shipping when place the order, and your order will be prioritized to minimize downtime.
  • For indent items, typical turnaround is 1-3 weeks, depending on parts availability and scarcity.
Customs & Documentation
We prepare clear, order-specific documentation for every international shipment, including the commercial invoice, packing list and available product or compliance documents. Before dispatch, our logistics team confirms the consignee details, declared value, shipping terms and destination requirements with you. Tracking information is provided after shipment, helping your team prepare for import clearance with confidence.
Documents checked before dispatch · Shipment details confirmed · Global tracking provided
Payment
Payment is by bank wire only in RMB/CNY, GBP, EUR or USD. Amikon does not accept credit cards or provide credit terms. Cleared payment is required before shipment unless the written quotation expressly states otherwise.
Product Condition
Factory New These are new and current items that are procured directly from the manufacturer.
New In Sealed Package Parts are new. They have not been used and still have their original package seal intact.
New in Original Package These parts are new. The packages were not originally sealed by their original manufacturer.
Quantity
Mobile *
Country/Region *
E-mail *
Company
Content *
(gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Amikong please read our privacy policy.
  • 20+

    years in automation
  • ISO 9001

    certified quality system
  • 12 months

    amikon warranty
  • 2-hour reply

    from your account manager
  • Success Story

    solutions in action
PRODUCT DESCRIPTION

Thermal conductivity gas transmitter

XMTC-62-11-0 is listed within the Panametrics XMTC thermal-conductivity gas-transmitter family. The manufacturer describes XMTC instruments as measuring constituent concentration in binary or pseudobinary gas mixtures. The exact calibration, measuring-cell package and suffix configuration of this ordering reference have not been independently established.

The retained XMTC family datasheet explains the measurement principle, sample-system requirements and available configurations. Before selecting a spare, confirm the gas mixture, concentration range, reference-gas arrangement and nameplate approvals. A suitable sample system is mandatory, and family options must not be assumed to be fitted to this unit.
ACTUAL APPLICATIONS

Application context for XMTC-62-11-0

XMTC-62-11-0 is a Thermal conductivity gas transmitter for compatible Fanuc CNC systems. Its application context includes chemical and petrochemical, oil and gas, metals. Suitability depends on the complete part number, equipment revision, electrical interfaces and documented configuration.
  • 01 · CHEMICAL & PETROCHEMICAL

    Industrial Chemical and Petrochemical Production

    Industrial Chemical ProductionPetrochemical Production and Processing
  • 02 · OIL & GAS

    Oil Extraction and Natural Gas Processing

    Oil Exploration and ProductionNatural Gas Processing
  • 03 · METALS

    Primary Metal Production and Metalworking

    Iron and Steel ProductionNonferrous Metal Processing

Technical specifications for XMTC-62-11-0

  • Product Model
    XMTC-62-11-0
  • Product Parameters
    Thermal conductivity gas transmitter
  • In stock
    1 unit
  • Manufacturer
    General Electric
  • Measurement principle
    Thermal conductivity using glass-coated thermistors (XMTC family)
  • Mixture requirement
    Binary or pseudobinary gas composition totaling 100% (family)
  • Family accuracy
    +/-2% of span
  • Family linearity
    +/-1% of span
  • Family repeatability
    +/-0.5% of span
  • Zero stability
    +/-0.5% of span per week (family)
  • Span stability
    +/-0.5% of span per week (family)
  • Response time
    20 seconds for 90% step change (family)
  • Analog output
    Isolated 4-20 mA, field-programmable (family)
  • Maximum output load
    800 ohms (family)
  • Power specification
    24 VDC +/-2 VDC; 1.2 A maximum in family specification table
  • Nominal sample flow
    250 cc/min in standard family sample-system example
  • Sample-system requirement
    Mandatory; clean representative sample within applicable limits
View all additional

Alternative Names

XMTC-62-11-0 Panametrics Transmitter XMTC-62-11-0 Thermal Conductivity Analyzer XMTC-62-11-0 Binary Gas Transmitter
SYSTEM & REPLACEMENT CHECK

Information needed before ordering

Three direct checks to secure your system integration and minimize ordering risks.

Information

System integration Replacement check Manuals & support
THERMAL CONDUCTIVITY GAS TRANSMITTER

Match the calibration and mandatory sample system

The XMTC family uses heated glass-coated thermistors to compare sample and reference gas thermal conductivity. The resulting signal represents a constituent concentration in a binary or pseudobinary mixture. The complete gas composition must be appropriate for this measurement method; an unspecified multicomponent stream is not automatically suitable.
BHCS38653 states that a sample system is mandatory and must deliver a clean, representative sample within the permitted temperature, pressure and flow limits. Its standard example uses a sample below 50 degrees C with a 55-degree-C measuring cell, approximately 250 cc/min flow and atmospheric pressure. Verify which temperature option and sample conditions apply to the installed unit.
The family datasheet offers two-port sealed-reference and four-port flowing-reference arrangements, different cell packages and several gas calibrations. The supplied XMTC-62-11-0 suffix has not been conclusively mapped to that ordering scheme. Confirm its label and calibration documentation before deciding on materials, port arrangement, hazardous-area suitability or connections.

Features:

  • Verify the complete gas mixture and calibrated range
  • Provide the documented sample-conditioning system
  • Confirm the installed cell, ports and approvals
The XMTC-62-11-0 gas transmitter requires appropriate configuration before system integration and commissioning.
INTERCHANGEABILITY

Verify the complete replacement identity before commissioning

Match XMTC-62-11-0 against the installed transmitter's nameplate and calibration records. Replacing an XMTC solely by its family name can overlook differences in gas range, cell construction, reference-gas arrangement, materials or temperature set point.
The manufacturer describes a plug-in measuring cell and field calibration for the family. This does not approve every spare cell for every transmitter. Verify the applicable cell and calibration instructions, and confirm the offered accessory scope before maintenance.
No exact-order discontinuation date or designated successor was verified. The retained 2023 family datasheet is not a lifecycle announcement, and it does not establish a fully interchangeable newer ordering number for this specific configuration.

Features:

  • Compare gas calibration and reference arrangement
  • Check measuring-cell and materials compatibility
  • Require exact-order evidence for any successor
The XMTC-62-11-0 gas transmitter requires replacement verification against the complete installed configuration and current manufacturer documentation.
DOCUMENTATION STATUS

Browse the Manuals, Datasheets, Official Documents, Links

Important Notice: The linked files are Amikong-hosted reference documents. Match their product identity and scope to the supplied assembly, and consult the applicable manufacturer instructions before use. Accessories and additional documents are included only when expressly listed in the quotation.

Features:

  • Verify document identity before procurement or installation
  • Match the complete order to the manufacturer document scope
  • Accessories are supplied only when listed in the quotation
Documentation for the XMTC-62-11-0 gas transmitter must be checked for document applicability before installation or commissioning.

Important notice

Manuals, software, firmware, cables, calibration data and accessories are included only when listed in the quotation. AMIKON is an independent supplier and is not affiliated with or authorised by the manufacturer.
This content has been produced using multiple sources. Takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
BUYER INFORMATION

Commercial terms without hidden steps

Your written quote confirms the product identity, price, availability, lead time, warranty and shipping terms before payment.
  • 01

    Shipping & delivery

    Dispatch
    Eligible stock: same / next day
    Carriers
    DHL, FedEx or UPS
    Ship from
    Xiamen, China
    Packed size
    Packing dimensions require confirmation
    Shipping weight
    Shipping weight requires confirmation
  • 02

    Payment & customs

    Payment
    Bank transfer (T/T)
    Currencies
    USD · EUR · GBP · RMB
    Credit cards
    Not accepted
    HS reference
    8537101190
    Origin
    USA
  • 03

    Warranty & returns

    Warranty
    12 months from AMIKON
    Inspection
    Label, condition and packing checks
    Returns
    Prior RMA authorisation required
    Compatibility
    Confirm before order
    OEM warranty
    Does not apply
Your written quote confirms the product identity, price, availability, lead time, warranty and shipping terms before payment.
  • Part checked

    Full suffix recorded
  • Condition checked

    Label and appearance
  • Packing checked

    Antistatic protection
  • Tracking supplied

    Established couriers
  • Sandy Lin

    Dedicated account manager · 15+ years
FREQUENTLY ASKED QUESTIONS

Questions buyers ask about XMTC-62-11-0

Direct answers about identity, compatibility, stock, warranty, payment and shipping.
  • Which gas range is configured in XMTC-62-11-0?

    The exact calibration has not been verified. Check the unit's calibration label and records; the family datasheet's available gas ranges are options, not proof of the configuration supplied.
  • Can an XMTC be used without a sample system?

    No. Panametrics states that a sample system is mandatory and must deliver a clean, representative sample within the acceptable temperature, pressure and flow limits.
  • What is the difference between sealed and flowing reference arrangements?

    The family offers a two-port version using sealed reference gas and a four-port version using a specific flowing reference gas. Confirm which measuring-cell package is installed rather than assuming either arrangement from the family name.
  • Does the family provide a 4-20 mA output?

    Yes. The specification lists an isolated, field-programmable 4-20 mA output with an 800-ohm maximum load. Confirm the installed configuration and follow its applicable wiring instructions.
  • Can it measure an arbitrary multicomponent gas stream?

    The datasheet describes binary or pseudobinary mixtures and states that the composition must total 100%. The complete gas mixture and calibration must be assessed for suitability; the instrument should not be assumed suitable for any unspecified multicomponent stream.
  • Are explosion-proof approvals confirmed for this exact order?

    The family includes different enclosure and approval options. No exact-order approval was established here, so verify the actual nameplate, certificate and installation conditions before hazardous-area use.
  • Can the measuring cell be replaced separately?

    Panametrics describes a replaceable plug-in measuring cell for the XMTC family. The correct cell, calibration and maintenance instructions still need to be matched to the installed transmitter; this is not universal spare-cell interchangeability approval.
READY TO VERIFY YOUR PART?

Get a XMTC-62-11-0 quote with price, lead time and revision check.

Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, drives and servo motors, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: Amikon Limited sells new and surplus products and develops channels for purchasing such products. Amikon Limited is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because Amikon Limited is not an authorized distributor of this product, the Original Manufacturer's warranty does not apply. Amikon Limited is not an authorized distributor, dealer, or representative of the products displayed on this website. All product names, trademarks, brands, and logos used on this website are the property of their respective owners. The description, explanation, or sale of products with these names, trademarks, brands, and logos is for identification purposes only and is not intended to indicate any association with or authorization from any rights holder.