General Electric IC695CMM004-BF
· Product image is representative; revision or series may vary. Contact us to request a specific version.
Ships by Sunday, October 11

IC695CMM004-BF

Serial Communications Module

Shipping Information

  • For inventory products, we support same day shipping upon payment.
  • For urgent needs, we offer same-day shipping on most items for orders placed before 2:00 PM UTC+8 Simply mention your preferred next-day shipping when place the order, and your order will be prioritized to minimize downtime.
  • For indent items, typical turnaround is 1-3 weeks, depending on parts availability and scarcity.
Customs & Documentation
We prepare clear, order-specific documentation for every international shipment, including the commercial invoice, packing list and available product or compliance documents. Before dispatch, our logistics team confirms the consignee details, declared value, shipping terms and destination requirements with you. Tracking information is provided after shipment, helping your team prepare for import clearance with confidence.
Documents checked before dispatch · Shipment details confirmed · Global tracking provided
Payment
Payment is by bank wire only in RMB/CNY, GBP, EUR or USD. Amikon does not accept credit cards or provide credit terms. Cleared payment is required before shipment unless the written quotation expressly states otherwise.
Product Condition
Factory New These are new and current items that are procured directly from the manufacturer.
New In Sealed Package Parts are new. They have not been used and still have their original package seal intact.
New in Original Package These parts are new. The packages were not originally sealed by their original manufacturer.
Quantity
Mobile *
Country/Region *
E-mail *
Company
Content *
(gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Amikong please read our privacy policy.
  • 20+

    years in automation
  • ISO 9001

    certified quality system
  • 12 months

    amikon warranty
  • 2-hour reply

    from your account manager
  • Success Story

    solutions in action
PRODUCT DESCRIPTION

IC695CMM004-BF Serial Communications Module

IC695CMM004-BF is a four-port serial communications module for GE PACSystems RX3i controllers. It expands the serial connections available to compatible instruments, controllers and other industrial communication devices.

Four independent isolated ports use RJ45 connectors and can be configured for RS232 or RS485/RS422 operation. Baud rate, parity, data bits, stop bits and flow control are set for each connection. Supported serial protocols depend on the installed firmware, while the backplane supplies the module power and exchanges data with the host CPU.
ACTUAL APPLICATIONS

Application context for IC695CMM004-BF

IC695CMM004-BF provides serial communications within compatible RX3i configurations for water treatment, manufacturing and industrial energy production. Connected device protocols, electrical interfaces and the installed firmware determine the supported communication arrangement.
  • 01 · WATER & WASTEWATER

    Water Treatment and Wastewater Processing

    Drinking Water Treatment ProcessesMunicipal Wastewater Treatment Processes
  • 02 · INDUSTRIAL MANUFACTURING

    Industrial Manufacturing and Production Automation

    Automated Manufacturing and ProductionFactory Production and Assembly
  • 03 · POWER GENERATION

    Electric Power and Energy Generation

    Electric Power Generation ProcessesIndustrial Steam and Power Generation

Technical specifications for IC695CMM004-BF

  • Product Model
    IC695CMM004-BF
  • Product Parameters
    Serial Communications Module
  • In stock
    7 units
  • Manufacturer
    General Electric
  • Serial ports
    4 independent isolated
  • Port connectors
    RJ45
  • Electrical interfaces
    RS232 or RS485/RS422
  • RS485 operating modes
    2-wire half-duplex or 4-wire full-duplex
  • RS232 flow control
    RTS/CTS or none
  • Baud rates
    1200, 2400, 4800, 9600, 19200, 38400, 57600 or 115200 bps
  • Data bits
    7 or 8
  • Stop bits
    1 or 2
  • Parity
    Even, odd or none
  • 3.3 V backplane current
    0.7 A maximum
  • 5 V backplane current
    0.150 A maximum
  • Modules per CPU
    6 maximum in the main CPU backplane
  • Port-to-backplane isolation
    250 V AC continuous; 1500 V AC for 1 minute
  • Port-to-port isolation
    500 V DC continuous; 710 V DC for 1 minute
  • RS485 input impedance
    Greater than 96 kilohm
View all additional

Alternative Names

IC695CMM004-BF PACSystems RX3i Serial Communications Module RX3i 4 independent isolated serial ports
SYSTEM & REPLACEMENT CHECK

Information needed before ordering

Three direct checks to secure your system integration and minimize ordering risks.

Information

System integration Replacement check Manuals & support
SYSTEM INTEGRATION

Integrate IC695CMM004-BF serial communications module

IC695CMM004-BF is a serial communications module in the PACSystems RX3i platform. Match the exact article and hardware revision to the installed backplane and controller configuration before allocating channels, connections or network resources.
Compare serial ports (4 independent isolated), port connectors (RJ45) and electrical interfaces (RS232 or RS485/RS422) with the project requirements. Use the applicable terminal assignments, power budget and grounding requirements from the manufacturer documentation.
Configure the supported operating modes for IC695CMM004-BF, then verify the affected signals or communications in the approved controller project. Record configuration changes, diagnostic results and the completed functional checks with the equipment record.

Features:

  • Serial ports: 4 independent isolated
  • Port connectors: RJ45
  • Electrical interfaces: RS232 or RS485/RS422
The IC695CMM004-BF serial communications module requires appropriate configuration before system integration and commissioning.
INTERCHANGEABILITY

Verify IC695CMM004-BF serial communications module

Replace IC695CMM004-BF after comparing the complete label, hardware revision and PACSystems RX3i role with the installed article. Confirm connector allocation and the supported controller configuration before exchanging the module.
Preserve the controller project and relevant channel or communication settings before removing IC695CMM004-BF. Photograph field connections and grounding, identify connected circuits, and isolate the required power supplies according to the manufacturer procedure.
Restore the approved configuration after fitting IC695CMM004-BF. Check module status indications, the affected I/O or network connections and the required operating responses, then retain the replacement identity and final acceptance results.

Features:

  • Serial ports: 4 independent isolated
  • Port connectors: RJ45
  • Electrical interfaces: RS232 or RS485/RS422
The IC695CMM004-BF serial communications module requires replacement verification against the complete installed configuration and current manufacturer documentation.
DOCUMENTATION STATUS

Browse the Manuals, Datasheets, Official Documents, Links

Important Notice: The linked files are Amikong-hosted reference documents. Match their product identity and scope to the supplied assembly, and consult the applicable manufacturer instructions before use. Accessories and additional documents are included only when expressly listed in the quotation.

Features:

  • Verify document identity before procurement or installation
  • Match the complete order to the manufacturer document scope
  • Accessories are supplied only when listed in the quotation
Documentation for the IC695CMM004-BF serial communications module must be checked for document applicability before installation or commissioning.

Important notice

Manuals, software, firmware, cables, calibration data and accessories are included only when listed in the quotation. AMIKON is an independent supplier and is not affiliated with or authorised by the manufacturer.
This content has been produced using multiple sources. Takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
BUYER INFORMATION

Commercial terms without hidden steps

Your written quote confirms the product identity, price, availability, lead time, warranty and shipping terms before payment.
  • 01

    Shipping & delivery

    Dispatch
    Eligible stock: same / next day
    Carriers
    DHL, FedEx or UPS
    Ship from
    Xiamen, China
    Packed size
    3.5 × 13 × 13.6cm
    Shipping weight
    0.20kg
  • 02

    Payment & customs

    Payment
    Bank transfer (T/T)
    Currencies
    USD · EUR · GBP · RMB
    Credit cards
    Not accepted
    HS reference
    8538900000
    Origin
    United States
  • 03

    Warranty & returns

    Warranty
    12 months from AMIKON
    Inspection
    Label, condition and packing checks
    Returns
    Prior RMA authorisation required
    Compatibility
    Confirm before order
    OEM warranty
    Does not apply
Your written quote confirms the product identity, price, availability, lead time, warranty and shipping terms before payment.
  • Part checked

    Full suffix recorded
  • Condition checked

    Label and appearance
  • Packing checked

    Antistatic protection
  • Tracking supplied

    Established couriers
  • Sandy Lin

    Dedicated account manager · 15+ years
FREQUENTLY ASKED QUESTIONS

Questions buyers ask about IC695CMM004-BF

Direct answers about identity, compatibility, stock, warranty, payment and shipping.
  • How are four serial connections allocated on the BF communications module?

    The IC695CMM004 family provides four independent isolated serial ports.
  • Which RS485 wiring modes are supported by the BF article?

    RS485 supports two-wire half-duplex and four-wire full-duplex operation.
  • How is hardware flow control configured for a BF RS232 connection?

    The RS232 port can use RTS/CTS hardware flow control or no flow control.
  • Which serial baud rates can be selected for a BF channel?

    The selectable rates are 1200 through 115200 bps, using the eight documented baud-rate settings.
  • How many CMM004-BF modules may be allocated to one CPU?

    Up to six serial communications modules may be located in the main RX3i CPU backplane.
  • What must be checked before enabling a serial protocol on the BF revision?

    Match the installed firmware and protocol support to the manufacturer release documentation before configuration.
  • Which revision details should accompany an order for the BF serial module?

    Provide the complete IC695CMM004-BF label, firmware, port protocol settings and required quantity.
  • Which BF port features should be recorded during receipt inspection?

    Compare the full IC695CMM004-BF label, revision and four RJ45 ports with the order; inspect the connectors and preserve the identity record.
READY TO VERIFY YOUR PART?

Get a IC695CMM004-BF quote with price, lead time and revision check.

Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, drives and servo motors, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: Amikon Limited sells new and surplus products and develops channels for purchasing such products. Amikon Limited is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because Amikon Limited is not an authorized distributor of this product, the Original Manufacturer's warranty does not apply. Amikon Limited is not an authorized distributor, dealer, or representative of the products displayed on this website. All product names, trademarks, brands, and logos used on this website are the property of their respective owners. The description, explanation, or sale of products with these names, trademarks, brands, and logos is for identification purposes only and is not intended to indicate any association with or authorization from any rights holder.
Product

Product Browsing History