Close Menu
Get Parts Quote
Name
Company *
WhatsApp / WeChat (For Faster Quote) *
Email *
Address
City
State / Province / Region
Zipcode
Country
Quantity *
Part Number *
Manufacturer
Preferred Condition
Additional Information
Cancel
In Stock
Fast Shipping Available
General Electric IC695CMU310
General Electric IC695CMU310
General Electric IC695CMU310
General Electric IC695CMU310
General Electric IC695CMU310
General Electric IC695CMU310
· Product image is representative; revision or series may vary. Contact us to request a specific version.
Ships by Thursday, November 12

IC695CMU310

RX3i Max-ON hot-standby redundancy CPU

Shipping Information

  • For inventory products, we support same day shipping upon payment.
  • For urgent needs, we offer same-day shipping on most items for orders placed before 2:00 PM UTC+8 Simply mention your preferred next-day shipping when place the order, and your order will be prioritized to minimize downtime.
  • For indent items, typical turnaround is 1-3 weeks, depending on parts availability and scarcity.
Customs & Documentation
We prepare clear, order-specific documentation for every international shipment, including the commercial invoice, packing list and available product or compliance documents. Before dispatch, our logistics team confirms the consignee details, declared value, shipping terms and destination requirements with you. Tracking information is provided after shipment, helping your team prepare for import clearance with confidence.
Documents checked before dispatch · Shipment details confirmed · Global tracking provided
Payment
Payment is by bank wire only in RMB/CNY, GBP, EUR or USD. Amikon does not accept credit cards or provide credit terms. Cleared payment is required before shipment unless the written quotation expressly states otherwise.
Product Condition
Factory New These are new and current items that are procured directly from the manufacturer.
New In Sealed Package Parts are new. They have not been used and still have their original package seal intact.
New in Original Package These parts are new. The packages were not originally sealed by their original manufacturer.
Quantity
Mobile *
Country/Region *
E-mail *
Company
Content *
(gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Amikong please read our privacy policy.
  • 20+

    years in automation
  • ISO 9001

    certified quality system
  • 12 months

    amikon warranty
  • 2-hour reply

    from your account manager
  • Success Story

    solutions in action
PRODUCT DESCRIPTION

IC695CMU310 RX3i Max-ON hot-standby redundancy CPU

GE IC695CMU310 is a RX3i Max-ON hot-standby redundancy CPU in the GE PACSystems RX3i range. Controller role: Max-ON hot-standby redundancy CPU. Redundancy arrangement: Two RX3i controllers. Data exchange: One or two dedicated Ethernet LANs.

The manufacturer's document records its interface and service limits. Control transfer: Two to three CPU logic scans. User RAM: 10 MB battery-backed. Before installation, compare the complete catalog code, installed connections and controller configuration.
ACTUAL APPLICATIONS

Application context for IC695CMU310

IC695CMU310 serves the documented GE PACSystems RX3i role in the industry areas below. The manufacturer's guide describes controller role as Max-ON hot-standby redundancy CPU and redundancy arrangement as Two RX3i controllers. Verify the installed configuration for the particular application.
  • 01 · POWER GENERATION

    Reserve Power and Grid Continuity

    Reserve Power GenerationGrid Continuity Services
  • 02 · OIL & GAS

    Fuel Transfer and Storage Operations

    Fuel Storage and DistributionIndustrial Energy Supply
  • 03 · DISTRICT ENERGY

    Industrial Boiler and Steam Services

    Industrial Steam GenerationBoiler House Utilities

Technical specifications for IC695CMU310

  • Product Model
    IC695CMU310
  • Product Parameters
    RX3i Max-ON hot-standby redundancy CPU
  • In stock
    1 unit
  • Manufacturer
    General Electric
  • Controller role
    Max-ON hot-standby redundancy CPU
  • Redundancy arrangement
    Two RX3i controllers
  • Data exchange
    One or two dedicated Ethernet LANs
  • Control transfer
    Two to three CPU logic scans
  • User RAM
    10 MB battery-backed
  • User flash
    10 MB non-volatile
  • 3.3 V supply draw
    1.25 A nominal
  • 5 V supply draw
    1.0 A nominal
  • Operating temperature
    0–60 °C
  • Boolean execution
    0.195 ms per 1000 Boolean instructions, typical
  • Serial interfaces
    RS-232 and RS-485
  • Serial protocols
    Modbus RTU Slave, SNP and Serial I/O
  • Program blocks
    Up to 512
  • Maximum program block
    128 KB
  • Clock drift
    2 seconds per day maximum
View all additional

Alternative Names

IC695CMU310 GE PACSystems RX3i RX3i Max-ON hot-standby redundancy CPU IC695CMU310 RX3i Max-ON hot-standby redundancy CPU
SYSTEM & REPLACEMENT CHECK

Information needed before ordering

Three direct checks to secure your system integration and minimize ordering risks.

Information

System integration Replacement check Manuals & support
SYSTEM INTEGRATION

Integrate IC695CMU310 rx3i max-on hot-standby redundancy cpu

The manufacturer source documents IC695CMU310 for GE PACSystems RX3i. It describes controller role as Max-ON hot-standby redundancy CPU. Match the controller assembly, slot or network identity and available power before connection.
Use the documented interface and connection arrangement. Redundancy arrangement is Two RX3i controllers; data exchange is One or two dedicated Ethernet LANs. Check all field conductors, configuration and external supply against the installed project.
At startup, review power and status indications, test every affected channel, port or function in sequence, then record the verified settings and exact installed revision for future maintenance.

Features:

  • Hot-standby CPU redundancy
  • Two-controller arrangement
  • One or two dedicated Ethernet LANs
The IC695CMU310 rx3i max-on hot-standby redundancy cpu requires appropriate configuration before system integration and commissioning.
INTERCHANGEABILITY

Verify IC695CMU310 rx3i max-on hot-standby redundancy cpu

Verify the full IC695CMU310 marking, including its suffix, before removing the installed unit. A base manual for IC695CMU310 must be read with any applicable revision information and the current hardware configuration.
Preserve the project and photograph wiring, connector assignments, slot position and indicators. Compare the replacement's controller role (Max-ON hot-standby redundancy CPU) and redundancy arrangement (Two RX3i controllers) with the service record.
After the change, restore the approved setup, confirm controller recognition and test affected signals or communications. Record the final nameplate and validation results.

Features:

  • I/O state retention during switchover
  • Hot-standby CPU redundancy
  • One or two dedicated Ethernet LANs
The IC695CMU310 rx3i max-on hot-standby redundancy cpu requires replacement verification against the complete installed configuration and current manufacturer documentation.
DOCUMENTATION STATUS

Browse the Manuals, Datasheets, Official Documents, Links

Important Notice: The linked files are Amikong-hosted reference documents. Match their product identity and scope to the supplied assembly, and consult the applicable manufacturer instructions before use. Accessories and additional documents are included only when expressly listed in the quotation.

Features:

  • Verify document identity before procurement or installation
  • Match the complete order to the manufacturer document scope
  • Accessories are supplied only when listed in the quotation
Documentation for the IC695CMU310 rx3i max-on hot-standby redundancy cpu must be checked for document applicability before installation or commissioning.

Important notice

Manuals, software, firmware, cables, calibration data and accessories are included only when listed in the quotation. AMIKON is an independent supplier and is not affiliated with or authorised by the manufacturer.
This content has been produced using multiple sources. Takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
BUYER INFORMATION

Commercial terms without hidden steps

Your written quote confirms the product identity, price, availability, lead time, warranty and shipping terms before payment.
  • 01

    Shipping & delivery

    Dispatch
    Eligible stock: same / next day
    Carriers
    DHL, FedEx or UPS
    Ship from
    Xiamen, China
    Packed size
    7 × 13.4 × 13.7 cm
    Shipping weight
    0.44 kg
  • 02

    Payment & customs

    Payment
    Bank transfer (T/T)
    Currencies
    USD · EUR · GBP · RMB
    Credit cards
    Not accepted
    HS reference
    8538900000
    Origin
    United States
  • 03

    Warranty & returns

    Warranty
    12 months from AMIKON
    Inspection
    Label, condition and packing checks
    Returns
    Prior RMA authorisation required
    Compatibility
    Confirm before order
    OEM warranty
    Does not apply
Your written quote confirms the product identity, price, availability, lead time, warranty and shipping terms before payment.
  • Part checked

    Full suffix recorded
  • Condition checked

    Label and appearance
  • Packing checked

    Antistatic protection
  • Tracking supplied

    Established couriers
  • Sandy Lin

    Dedicated account manager · 15+ years
FREQUENTLY ASKED QUESTIONS

Questions buyers ask about IC695CMU310

Direct answers about identity, compatibility, stock, warranty, payment and shipping.
  • How should IC695CMU310 be checked before ordering?

    Compare the full catalog and suffix with the installed label, GE PACSystems RX3i assembly and manufacturer document.
  • Can another revision of IC695CMU310 replace IC695CMU310?

    Do not infer interchangeability from the shared base number. Check applicable release notes, firmware and project compatibility.
  • What should engineers record before exchanging IC695CMU310?

    Save the approved project and record the slot, full nameplate, connector or terminal assignments, supply and current diagnostics.
  • How should IC695CMU310 be tested after installation?

    Confirm controller recognition and status, exercise each affected function with a known condition, and archive the measured outcome.
  • Which manual covers IC695CMU310?

    The linked manufacturer document covers base article IC695CMU310. Verify the particular IC695CMU310 suffix against the delivered module.
  • What does a distributor need to quote IC695CMU310?

    Send the complete order code, quantity, condition, delivery country and a legible label photo if revision matching is critical.
  • How should incoming IC695CMU310 be inspected?

    Compare the full label and condition against the quotation; inspect contacts, housing and included accessories before installation.
  • What should be checked if IC695CMU310 is not recognized?

    Confirm the correct slot or network position, supply, bus or firmware compatibility and project configuration before replacing other hardware.
READY TO VERIFY YOUR PART?

Get a IC695CMU310 quote with price, lead time and revision check.

Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, drives and servo motors, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: Amikon Limited sells new and surplus products and develops channels for purchasing such products. Amikon Limited is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because Amikon Limited is not an authorized distributor of this product, the Original Manufacturer's warranty does not apply. Amikon Limited is not an authorized distributor, dealer, or representative of the products displayed on this website. All product names, trademarks, brands, and logos used on this website are the property of their respective owners. The description, explanation, or sale of products with these names, trademarks, brands, and logos is for identification purposes only and is not intended to indicate any association with or authorization from any rights holder.