5 Vdc & watchdog distribution module
Product No. : 10313/1/1
Product Type : Termination Module
5 VDC + Watchdog Distribution Module CC
Max. current on faston pin: 4 A
connector pin: 2 A
Non-redundant IO Termination Assembly
Line monitored digital input
Non line monitored digital input
Line monitored ESD input (on Channel 32)
Analog input 0-20mA or 4-20mA
Digital output (0.5 Amp) configurable line monitoring
Multiple digital output (1 Amp or 2 Amp)
with or without line monitoring
Analog output 0-20mA or 4-20mA
IKB keyboard
KB GUS W/TRKBAL
Integrated into GUS console
workstation docking
Temperature Range:0°C to +50°C operational
Trackball Resolution:High-precision
Legacy RS-232 or proprietary protocols
Horizontal IO bus transfer board
Voltage: 24 V DC (±10%)
Power Consumption: ≤10 W (typical)
Isolation: 1500 V AC
Operating Temperature: -40°C to +70°C (-40°F to +158°F)
Storage Temperature: -50°C to +85°C (-58°F to +185°F)
Humidity: 5–95% RH (non-condensing)
I/O Extender Module
Space requirements:4 TE, 3 HE (= 4 HP, 3U)
current: max. 10 mA (WD1in + WD2in)
Number of outputs:18
power requirements:100 mA
current: + 5V_load of all (18) IO boards
+ WD_load of all (18) IO boards
voltage drop:0.2V < V < 0.8V
Digital Output Module
Output Channels:32
Load Voltage:30 VDC Maximum
Load Current :0.1 A per channel
Galvanic Isolation :1000 VAC RMS for System3
Off-State Voltage:24 V
Off-State Leak Current:100 µA (max)
Turn-On/Turn-Off Time:10 ms (max)
Universal Safety Interface
UNIVERSAL SAFETY INTERFACE
MMEM CC, EUCN
Approvals: CE, TUV, UL, CSA, FM
5 V supply voltage: 5 V DC ± 5%
5 V supply current: max 1.2A
Operating temperature:-5°C - +70°C (+23°F - +158°F)
Storage temperature: -40°C - +85°C (-40°F - +185°F)
Relative humidity: 10 - 95% (non condensing)
Revision C IO Link Cable
Type: IO Link Cable
Part Number: 51202341-102 Revision C
Country of Origin: USA
Cable Length: 1 meter
Shielding: Shielded
HORIZONTAL BACK PLANE PWA
Operating Voltage: 24 V DC
Input Current: 1 A
Output Power: 20 W
Bus Interface: RS-485
Operating Temperature: -20°C to +70°C
Humidity Range: 5% to 95% non-condensing
Certifications: CE, UL, ISO 9001
Digital Output IOTA Redundant
Output Channels:32
Output Type SINK: (Open Drain)
Load Current :0.1 A per channel (Max)
On-State Voltage 0v VDC (load current @:0.1A max
Off-State Voltage:24 V (typ),
Off-State Leak Current:100 µA (max)
Turn-On/Turn-Off Time:10 ms (max)
Digital Input IOTA Redundant
Power supply:24V DC
Rated Current:55mA at 24V
Power Consumption:1.32W at 20mA
Power/DCS to Field:1500 VAC
DCS side connections:
37 pin DSUB connector on CC-UGIA01
Voltage Input:24V DC
Interface to DCS:4 to 20mA with HART
Analog Output IOTA Redundant
Power supply 24V DC
Rated Current 55mA at 24V
Power Consumption 1.32W
Power/DCS to Field 1500 VAC
DCS side connections 37 pin
DSUB connector on CC-UGIA01
Voltage Input 24V DC
Current Input 4 to 20mA with HART,
CC-UGAI01 in sink mode.
Open wire current <150uA
Digital module
Channels: 16 digital channels
Input Type: 24 VDC
Isolation:500 VDC
Update Rate: ≤10 ms
Power Consumption: ≤5 W
Operating Temperature: -40°C to +70°C (-40°F to +158°F).
Humidity: 5–95% non-condensing.
SC S300 SAFETY CONTROLLER SIL3
Input Voltage: 24 VDC (±10%)
Output Voltage: 24 VDC
Current Capacity: Typically up to 5A
Operating Temperature: -40°C to +70°C (-40°F to +158°F).
Humidity: 5–95% non-condensing
SC S300 SAFETY CONTROLLER SIL3
Digital Inputs:24 VDC
Cycle Time: <10 ms
Operating Temperature: -20°C to +60°C (-4°F to +140°F)
Contact Rating: 5A @ 250VAC
Operating Force: 1.8N minimum
Release Force: 0.1N minimum
Pre-travel: 1.5mm maximum
Redundant Net Interface Module
REDUNDANT NET INTERFACE MODULE
CAGE CARD
24 VDC
(PN-14251 / 14251)
ANALOG OUTPUT MODULE
I/O LINK INTERFACE
FIBER OPTIC CONVERTER
9 PORTS
ANALOG OUTPUT MODULE
Enhanced Logic Manager Module
Input Voltage:Typically 24 VDC
Power Consumption:Around 25 W
Operating Temperature Range:Typically -20°C to 60°C
Storage Temperature Range:-40°C to 85°C.
Relative Humidity:5% to 95% non-condensing.
ACTUATOR
MODUTROL IV MOTOR
NON-SPRING RETURN
FOOT MOUNTED
4-20 MA MODULATING CONTROL SIGNAL
160 DEGREE STROKE
15-30 SECONDS TIMING
8.5 NM / 75 LB-IN TORQUE RATING
15 VA
120 VAC
50/60 HZ
memory backup module
C300v5 controller
memory backup module
C300 Memory Backup Assembly
Power Requirements: 24 V DC
Current Draw: 150 mA
Operating Temperature Range: 0°C to 70°C
Open Plant Controller
ComfortPoint™ Open solution
fully programable
BACnet-Building Controller (B-BC)
for AHU, RTU and Central Plant applications
CPO-Studio compatible
CPO-Room Controller
ROOM CONTROLLER
CONTROLPOINT
BACNET
MS/TP
6 ANALOG OUTPUTS
4 RELAYS
4 TRIACS
230 VAC
Actuator Controller
Operating Voltage:24 VAC ± 10%
Power Consumption:15 VA
6 DOs (Triac output, 2 reserved for internal actuator)
Maximum voltage: 24 VAC
Maximum continuous current: 500 mA
Minimum current: 30 mA
3 AOs, 0 -10 Vdc
Resolution: 12-bit

Copyright Notice © 2004-2024 amikong.com All rights reserved
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.