Controller Interface
HCiRX Series
5.7” Color TFT LCD
Screen Size 5.6 ”
Resolution 640 x 480
LCD Color TFT 16M Colors
Brightness 450 cd / m2
Touch Type Analog Resistive
Touch Cell 640 x 480
CPU 32 bit RISC
Flash Memory 128MB
8 channel Current Input Module
Input Resistance: 1 MΩ min
16-bit binary value
±0.2% or less
250 μs/channel
ANALOG INPUT: 1~ 5 V
Unsigned Value:0 ~ 16000
16 point Transistor Output Module
OUTPUT MODULE 16POINT
DIGITAL MASTERLOGIC-200
DC 10.2 ~ 26.4V
16 point / 1COM
External connection method 18 point
terminal block connector
Digital Input Module
INPUT MODULE
MASTERLOGIC
DIGITAL
8 POINT
INPUT / 17 MA / 220 VAC
CONFORMAL CODE
POWER SUPPLY MODULE
Redundant CPU
Redundant Power
Redundant I/O cable
Cyclic scan
Time-driven interrupts
InternalMemory interrupts
CPU Module
Max. I/O: 3,072Pts
128KB Program Memory
IEC, Standard
Reiterative operation
fixed cycle operation
constant scan
Ladder Diagram
Redundant Controller
Minimum PowerConsumption
where thereare no expansion IOMs
Power is supplied to the controller
I/O modules through the power input terminals
the controller IOTA and the left endplate, (when used)
The relevant specifications at each
power input terminals are detailed below
CAB Developer
CAB Developer
Application Development Tools
Application Enablers
Enables ODBC driver
ODBC data exchange
Equipment Point Adders to Database Size
100 Equipment Point Adders to Database Size
Application Development Tools
and Application Enablers
Enables ODBC driver
ODBC data exchange
server automation object features
Quad Processor Pack
Two processors running synchronously
Flash memory for system and application program
Flash memory for backup of system and application program
RAM with battery backup (battery located in BKM-0001)
Aredundant communication link with the other Control Processor
RAM for the redundant communication link data
Data comparators for the processors and their memory
Data exchange with its communication modules
PlantCruise 50,000 SCADA Points Redundancy Adder
Server Redundancy
SCADA Points
PlantCruise 50,000 SCADA Points
Redundancy Adder
PlantCruise 100 SCADA Points Adder
PlantCruise 100 SCADA Points Adder
to Database Size
PlantCruise SCADA Point Adder 100 POINT
PlantCruise 100 Process Point Adder
PlantCruise 100 Process Points Adder
to Database Size
Software License
PlantCruise DCS System
Requires PlantCruise Base (CV-DBASE1)
PlantCruise Process points with base
Active Directory/LDAP
PlantCruise (Process Points License)
Up to 50,000
Scan Rate:100ms (configurable)
Alarm Handling:10,000 alarms/sec
Historical Data Storage:1M tags @ 1-sec intervals
Redundancy Switchover:<1 sec
PlantCruise Base Software
SCADA Interfaces
OPC and Data Exchange Options
Version Designation:CV-DBASE1
Type:Process Control System
Architecture:Distributed Client-Server
Deployment:Virtualized/Physical
Real-time Control:100ms scan cycles
I/O Capacity:50,000 points
Alarm Management:10,000 alarms/sec
Historical Storage:1M tags @ 1sec intervals
Redundancy:Hot standby servers
Safety Builder R100.3 software
Model Number:FS-SMSB-ST-120
Software Name:Safety Builder R100.3
Processor:Intel i7 2.8GHz or equivalent
RAM:16GB (32GB recommended)
Storage:500GB SSD
Basic Windows 2000/XP
CONNECTOR CABLE
CONNECTOR CABLE
I/O LINK
30V
20PX28AWG
40-PIN FEMALE CONNECTOR
3 FT LENGTH
CONNECTOR CABLE
CONNECTOR CABLE
I/O LINK
30V
20PX28AWG
40-PIN FEMALE CONNECTOR
4-1/2 FT LENGTH
DeviceNet Master module
Model Number:2MLL-DMEB
Type:DeviceNet Master/Scanner Module
Input Voltage:24V DC (18-36V)
Power Consumption:5.5W (typical)
Network Interface:5-pin screw terminal
Isolation:1500V AC
Surge Protection:±2kV
PROFIBUS-DP REMOTE INTERFACE
PROFIBUS-DP REMOTE INTERFACE
I/O MODULE
Profibus, Remote Interface
DP standard
used on ML200 racks only
Computer Link I/F Module
Model Number:2MLL-CH2B
Type:High-Speed Computer Communication Interface
Input Voltage:24V DC (18-36V)
Power Consumption:3.8W
Isolation :1500V AC )
Port Configuration:2x serial ports
Surge Protection:±2kV
Data Rate:300-115.2kbps
Analog Input and Output Module
Model Number:2MLL-C42B
Type:High-Density Analog I/O Module
Channels:4 AI + 2 AO (Isolated)
Resolution:16-bit (0.0015% of span)
Voltage Ranges:±10V, 0-10V
Current Ranges:0-20mA, 4-20mA
Accuracy:±0.05% of span
Update Rate:10ms/channel
Isolation:1500V ch-ch
Cnet I/F Module
Model:2Mll-c22B / C22B
Operating System:V5.00
Communication Interface:Cnet I/F, RS-232C, 2Ch
Input Voltage:24V DC
Power Consumption:4.8W (typical)
Network Connector:BNC
Isolation:1500V AC
Surge Protection:±2kV

Copyright Notice © 2004-2024 amikong.com All rights reserved
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.