Honeywell 10310/2/1
· Product image is representative; revision or series may vary. Contact us to request a specific version.
Ships by Tuesday, September 29

10310/2/1

earth leakage detector

Shipping Information

  • For inventory products, we support same day shipping upon payment.
  • For urgent needs, we offer same-day shipping on most items for orders placed before 2:00 PM UTC+8 Simply mention your preferred next-day shipping when place the order, and your order will be prioritized to minimize downtime.
  • For indent items, typical turnaround is 1-3 weeks, depending on parts availability and scarcity.
Customs & Documentation
We prepare clear, order-specific documentation for every international shipment, including the commercial invoice, packing list and available product or compliance documents. Before dispatch, our logistics team confirms the consignee details, declared value, shipping terms and destination requirements with you. Tracking information is provided after shipment, helping your team prepare for import clearance with confidence.
Documents checked before dispatch · Shipment details confirmed · Global tracking provided
Payment
Payment is by bank wire only in RMB/CNY, GBP, EUR or USD. Amikon does not accept credit cards or provide credit terms. Cleared payment is required before shipment unless the written quotation expressly states otherwise.
Product Condition
Factory New These are new and current items that are procured directly from the manufacturer.
New In Sealed Package Parts are new. They have not been used and still have their original package seal intact.
New in Original Package These parts are new. The packages were not originally sealed by their original manufacturer.
Quantity
Mobile *
Country/Region *
E-mail *
Company
Content *
(gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Amikong please read our privacy policy.
  • 20+

    years in automation
  • ISO 9001

    certified quality system
  • 12 months

    amikon warranty
  • 2-hour reply

    from your account manager
  • Success Story

    solutions in action
PRODUCT DESCRIPTION

10310/2/1 earth leakage detector

HONEYWELL 10310/2/1 earth leakage detector supports Honeywell Safety Manager systems. The assembly combines the documented electrical, signal and mechanical interfaces for its assigned system position. It processes or transfers the defined operating signals through the configured equipment path. The resulting interface supports repeatable control, protection or measurement performance within the approved installation.
ACTUAL APPLICATIONS

Verified application context for 10310/2/1

Manufacturer documentation supports these equipment applications when the complete system configuration and interfaces are verified.
  • 01 · OIL & GAS

    Emergency shutdown cabinet power distribution

    Safety DC systemsCompressor shutdown relay power panelsPipeline isolation solenoid power circuits
  • 02 · CHEMICAL PROCESSING

    Reactor interlock and trip power panels

    Protective power systemsReactor trip relay supply cabinetsProcess isolation valve trip circuits
  • 03 · POWER GENERATION

    Turbine and boiler protection cabinets

    Plant trip systemsTurbine emergency trip DC busesBoiler burner interlock power panels

Technical specifications for 10310/2/1

  • Product Model
    10310/2/1
  • Product Parameters
    earth leakage detector
  • In stock
    1 unit
  • Manufacturer
    Honeywell
  • Monitored DC Systems
    24, 48, 60 or 110 V DC
  • Module Supply Voltage
    24 V DC, 30 V DC maximum
  • Supply Current
    60 mA maximum
  • Rst24 Input Range
    18 to 70 V DC
  • Rst110 Input Range
    40 to 130 V DC
  • Rst24 Input Current
    1.1 mA at 24 V DC
  • Rst110 Input Current
    2.5 mA at 110 V DC
  • Normal Earth Voltage
    -12 V DC
  • Earth Fault Threshold
    -30 to +125 V DC
  • Earth Current Range
    5.5 mA ±1 mA
  • Alternate Earth Current
    25.0 mA ±5 mA
  • Maximum Output Voltage
    115 V DC
  • Maximum Output Current
    2 A
  • Relay Switched Load
    100 W or 1000 VA
  • Module Keying
    Holes A5 and A11
View all additional

Alternative Names

10310/2/1 HONEYWELL earth leakage detector Honeywell Safety Manager systems earth leakage detector
SYSTEM & REPLACEMENT CHECK

Information needed before ordering

Three direct checks to secure your system integration and minimize ordering risks.

Information

System integration Replacement check Manuals & support
SYSTEM INTEGRATION

Match 10310/2/1 to the installed Honeywell Safety Manager systems

HONEYWELL 10310/2/1 is a earth leakage detector for the Honeywell Safety Manager systems. Its exact article suffix determines the supported interface, signal or communication function and the approved companion equipment.
Engineering should compare rst24 input range (18 to 70 V DC), rst110 input range (40 to 130 V DC) and rst24 input current (1.1 mA at 24 V DC) with the installed system design. Confirm connector keying, addressing and configuration-tool support before connection.
Use the manufacturer documentation for the complete wiring and configuration sequence. Validate communication, signal conversion or control response with the connected equipment, then archive measured results and the final configuration with the asset record.

Features:

  • Exact identity: 10310/2/1
  • Product class: earth leakage detector
  • Family: Honeywell Safety Manager systems
The HONEYWELL 10310/2/1 requires documented system integration before energising the equipment.
REPLACEMENT CONTROL

Verify the complete 10310/2/1 identity before exchange

Replace 10310/2/1 only after matching the complete article code, earth leakage detector, installed Honeywell Safety Manager systems role and documented hardware or firmware revision. Similar housings and related family numbers do not establish functional interchangeability.
Photograph the nameplate, keyed connectors, terminal numbering, cable routing, shields, earth points and adjacent modules. Export the applicable controller, HMI, drive or network configuration and record addresses, parameters and diagnostic messages before removal.
After fitting the verified article, restore the controlled configuration and check every affected signal or communication path. Review status indications and diagnostic buffers, run the documented functional test at a safe operating point and retain the final acceptance record.

Features:

  • Exact identity: 10310/2/1
  • Product class: earth leakage detector
  • Family check: Honeywell Safety Manager systems
The HONEYWELL 10310/2/1 requires documented replacement verification before energising the equipment.
DOCUMENTATION STATUS

Browse the Manuals, Datasheets, Official Documents, Links

Important Notice: Official documents are provided through manufacturer links. Accessories, manuals, cables, calibration data, software and certificates are included only when listed in the quotation.

Features:

  • Official CA-H200C product references are checked before order
  • Confirm camera and controller compatibility in current manuals
  • Accessories are supplied only when listed in the quotation
Documentation for the KEYENCE CA-H200C cable must be matched to the connected camera and controller; confirm manual availability in the written quotation.

Important notice

Manuals, software, firmware, cables, calibration data and accessories are included only when listed in the quotation. AMIKON is an independent supplier and is not affiliated with or authorised by the manufacturer.
This content has been produced using multiple sources. Takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
BUYER INFORMATION

Commercial terms without hidden steps

Your written quote confirms the product identity, price, availability, lead time, warranty and shipping terms before payment.
  • 01

    Shipping & delivery

    Dispatch
    Eligible stock: same / next day
    Carriers
    DHL, FedEx or UPS
    Ship from
    Xiamen, China
    Packed size
    2.0 × 12.0 × 18.0 cm
    Shipping weight
    0.50 kg
  • 02

    Payment & customs

    Payment
    Bank transfer (T/T)
    Currencies
    USD · EUR · GBP · RMB
    Credit cards
    Not accepted
    HS reference
    85371098
    Origin
    United States
  • 03

    Warranty & returns

    Warranty
    12 months from AMIKON
    Inspection
    Label, condition and packing checks
    Returns
    Prior RMA authorisation required
    Compatibility
    Confirm before order
    OEM warranty
    Does not apply
Your written quote confirms the product identity, price, availability, lead time, warranty and shipping terms before payment.
  • Part checked

    Full suffix recorded
  • Condition checked

    Label and appearance
  • Packing checked

    Antistatic protection
  • Tracking supplied

    Established couriers
  • Sandy Lin

    Dedicated account manager · 15+ years
FREQUENTLY ASKED QUESTIONS

Questions buyers ask about 10310/2/1

Direct answers about identity, compatibility, stock, warranty, payment and shipping.
  • Which identifier should be quoted for 10310/2/1?

    Use the complete 10310/2/1 identifier, earth leakage detector, quantity and clear nameplate photographs.
  • What should be matched before installing 10310/2/1?

    Match the documented ratings, connections, revision and assigned role in Honeywell Safety Manager systems.
  • What should incoming inspection cover for 10310/2/1?

    Inspect the label, housing, connectors, terminals and transport condition before use.
  • Can a related Honeywell Safety Manager systems article replace 10310/2/1?

    Do not assume interchangeability; compare the full identity, ratings, interfaces and configured role.
  • Which records should be captured before removing 10310/2/1?

    Record connector positions, wire labels, cabinet location, adjacent hardware and current diagnostics.
  • Which configuration should be retained for 10310/2/1?

    Archive the applicable controller or monitoring configuration, addresses and diagnostic records.
  • How should 10310/2/1 be commissioned after installation?

    Restore verified wiring and configuration, then test the affected earth leakage detector function under controlled conditions.
  • Which documents should remain with the 10310/2/1 asset record?

    Retain receiving inspection, nameplate images, connection records, test results and final acceptance evidence.
READY TO VERIFY YOUR PART?

Get a 10310/2/1 quote with price, lead time and revision check.

Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, drives and servo motors, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: Amikon Limited sells new and surplus products and develops channels for purchasing such products. Amikon Limited is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because Amikon Limited is not an authorized distributor of this product, the Original Manufacturer's warranty does not apply. Amikon Limited is not an authorized distributor, dealer, or representative of the products displayed on this website. All product names, trademarks, brands, and logos used on this website are the property of their respective owners. The description, explanation, or sale of products with these names, trademarks, brands, and logos is for identification purposes only and is not intended to indicate any association with or authorization from any rights holder.