Invensys 3636T
· Product image is representative; revision or series may vary. Contact us to request a specific version.

3636T

Relay Output Module

Shipping Information

  • For inventory products, we support same day shipping upon payment.
  • For urgent needs, we offer same-day shipping on most items for orders placed before 2:00 PM UTC+8 Simply mention your preferred next-day shipping when place the order, and your order will be prioritized to minimize downtime.
  • For indent items, typical turnaround is 1-3 weeks, depending on parts availability and scarcity.
Customs & Documentation
We prepare clear, order-specific documentation for every international shipment, including the commercial invoice, packing list and available product or compliance documents. Before dispatch, our logistics team confirms the consignee details, declared value, shipping terms and destination requirements with you. Tracking information is provided after shipment, helping your team prepare for import clearance with confidence.
Documents checked before dispatch · Shipment details confirmed · Global tracking provided
Payment
Payment is by bank wire only in RMB/CNY, GBP, EUR or USD. Amikon does not accept credit cards or provide credit terms. Cleared payment is required before shipment unless the written quotation expressly states otherwise.
Product Condition
Factory New These are new and current items that are procured directly from the manufacturer.
New In Sealed Package Parts are new. They have not been used and still have their original package seal intact.
New in Original Package These parts are new. The packages were not originally sealed by their original manufacturer.
Quantity
Mobile *
Country/Region *
E-mail *
Company
Content *
(gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Amikong please read our privacy policy.
  • 20+

    years in automation
  • ISO 9001

    certified quality system
  • 12 months

    amikon warranty
  • 2-hour reply

    from your account manager
  • Success Story

    solutions in action
PRODUCT DESCRIPTION

3636T - Relay Output Module

Triconex 3636T is a non-triplicated Relay Output Module with thirty-two non-commoned, normally open output contacts. Its exact-model point-isolation minimum is 2500 VDC.

Match the connected load to the 155 VAC/VDC voltage ceiling, 2 A current limit and applicable switching-power limits. Reactive and incandescent loads require separate assessment; point indicators are asserted only by the primary module.
ACTUAL APPLICATIONS

Where 3636T provides relay-contact switching

The original relay specification separates voltage, current and load-dependent switching limits. Apply every relevant limit to the engineered circuit.
  • 01 · ISOLATION REVIEW

    Match the exact point-isolation class

    Use the documented 2500 VDC minimum for 3636T when reviewing the system interface. Keep this isolation specification separate from the 155 VAC/VDC maximum switched voltage.
  • 02 · LAMP CIRCUITS

    Check incandescent starting demand

    Assess lamp inrush rather than nominal running current alone. The guide warns that inrush can reach ten to fifteen times the nominal lamp current and directs users to lamp-manufacturer data.
  • 03 · SWITCHING DUTY

    Evaluate relay contact utilization

    Compare the required output cycle rate and operating duty with the documented relay limits. Expected life is specified at maximum rated load and is not an unrestricted service-life guarantee.

Technical specifications for 3636T

  • Product Model
    3636T
  • Product Parameters
    Relay Output Module
  • Manufacturer
    Invensys
  • Output architecture
    Non-triplicated relay outputs
  • Output points
    32, non-commoned
  • Contact arrangement
    Normally open
  • Maximum switched voltage
    155 VAC/VDC
  • Maximum load current
    2 A
  • Resistive switching power
    2000 VA; 150 W maximum
  • Reactive-load derating
    25% of maximum switching power; 37.5 W for DC
  • Maximum output cycle rate
    Less than 30 cycles per second
  • Expected life at maximum rated load
    More than 10,000 cycles
  • Field fuse requirement
    One 2.5 A fast-acting fuse per output
  • Point isolation minimum
    2500 VDC
  • Logic power with all points off
    Less than 10 W
  • Logic power with all points on
    Less than 20 W
  • Module status indicators
    Pass, Fault and Active
  • Point indicator behavior
    Only the primary module asserts point LEDs
View all additional

Alternative Names

3636T Triconex 3636T Tricon Relay 3636T
SYSTEM & REPLACEMENT CHECK

Information needed before ordering

Three direct checks to secure your system integration and minimize ordering risks.

Information

System integration Replacement check Manuals & support
SYSTEM CONFIGURATION

Match relay contacts, protection and switching duty

Triconex 3636T is a non-triplicated Relay Output Module with thirty-two non-commoned, normally open output contacts. Its exact-model point-isolation minimum is 2500 VDC.
Match the connected load to the 155 VAC/VDC voltage ceiling, 2 A current limit and applicable switching-power limits. Reactive and incandescent loads require separate assessment; point indicators are asserted only by the primary module.
Apply voltage, current and power limits together. Review reactive-load derating and lamp inrush; do not use the isolation-test rating as a field operating voltage.

Features:

  • 32 non-commoned relay outputs
  • Normally open contact arrangement
  • 2500 VDC minimum point isolation
The 3636T requires configuration and installation checks before system integration and commissioning.
INTERCHANGEABILITY

Verify the complete replacement identity before commissioning

Preserve the exact 3636T identity and 2500 VDC point-isolation class. Use the manufacturer active-module checks before removing a faulty I/O module.
Match the connected load to the 155 VAC/VDC voltage ceiling, 2 A current limit and applicable switching-power limits. Reactive and incandescent loads require separate assessment; point indicators are asserted only by the primary module.
Retain the validated safety logic and proof-test records. Recommission affected channels under the approved site procedure.

Features:

  • 32 non-commoned relay outputs
  • 2500 VDC minimum point isolation
  • Load-dependent switching limits
The 3636T requires replacement verification of relay contact wiring, protection and load behavior before commissioning.
DOCUMENTATION STATUS

Browse the Manuals, Datasheets, Official Documents, Links

Important Notice: The Manufacturer's Manual download is a manufacturer technical-data extract, not a complete operation manual. The installation guide contains only source-supported checks. Specifications of other configurations shown on source pages must not be applied to this exact order.

Features:

  • Sources: Invensys Tricon v9-v10 Planning and Installation Guide, 9720077-012, February 2009
  • Use complete equipment instructions for installation and commissioning.
  • Accessories are supplied only when listed in the quotation
Documentation for the 3636T is supplied here as a technical-data extract; confirm manual availability in the written quotation.

Important notice

Manuals, software, firmware, cables, calibration data and accessories are included only when listed in the quotation. AMIKON is an independent supplier and is not affiliated with or authorised by the manufacturer.
This content has been produced using multiple sources. Takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
BUYER INFORMATION

Commercial terms without hidden steps

Your written quote confirms the product identity, price, availability, lead time, warranty and shipping terms before payment.
  • 01

    Shipping & delivery

    Dispatch
    Eligible stock: same / next day
    Carriers
    DHL, FedEx or UPS
    Ship from
    Xiamen, China
    Packed size
    2.2 × 40.6 × 39.8 cm
    Shipping weight
    2.42 kg
  • 02

    Payment & customs

    Payment
    Bank transfer (T/T)
    Currencies
    USD · EUR · GBP · RMB
    Credit cards
    Not accepted
    HS reference
    8537101190
    Origin
    USA
  • 03

    Warranty & returns

    Warranty
    12 months from AMIKON
    Inspection
    Label, condition and packing checks
    Returns
    Prior RMA authorisation required
    Compatibility
    Confirm before order
    OEM warranty
    Does not apply
Your written quote confirms the product identity, price, availability, lead time, warranty and shipping terms before payment.
  • Part checked

    Full suffix recorded
  • Condition checked

    Label and appearance
  • Packing checked

    Antistatic protection
  • Tracking supplied

    Established couriers
  • Sandy Lin

    Dedicated account manager · 15+ years
FREQUENTLY ASKED QUESTIONS

Questions buyers ask about 3636T

Direct answers about identity, compatibility, stock, warranty, payment and shipping.
  • What exact isolation distinction separates 3636T from 3636R?

    The table gives 2500 VDC minimum for 3636T and 1500 VDC minimum for 3636R. This does not establish unconditional interchangeability.
  • Can the relay output cycle at thirty times per second or faster?

    The specified maximum cycle rate is less than 30 cycles per second. Use the stated limit when assessing switching duty.
  • Does the contact-life figure promise continuous lifetime operation?

    No. The guide states more than 10,000 cycles at maximum rated load. Actual duty and load characteristics must be assessed separately.
  • Why must lamp starting current be included in the switching calculation?

    Incandescent-lamp inrush may be ten to fifteen times nominal load current. The guide requires using inrush in the switching-power calculation.
  • Where should the duration and amplitude of lamp inrush be obtained?

    The manufacturer directs users to the lamp manufacturer for detailed inrush amplitude and duration, rather than deriving those details from the relay nominal current rating.
  • May the VA and watt limits be treated as the same quantity?

    No. The relay table separately lists 2000 VA and 150 W maximum for resistive switching. Apply the appropriate power limit along with the voltage and current limits.
  • What must be true before withdrawing a faulty I/O module?

    The manufacturer requires an Active replacement or hot spare and the faulty module Active indication off. Do not withdraw it merely because another module is physically present.
  • Can multiple replacement I/O modules be inserted simultaneously?

    No. The general module-replacement rules require one module at a time and waiting for its Active indication before installing the next.
READY TO VERIFY YOUR PART?

Get a 3636T quote with price, lead time and revision check.

Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, drives and servo motors, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: Amikon Limited sells new and surplus products and develops channels for purchasing such products. Amikon Limited is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because Amikon Limited is not an authorized distributor of this product, the Original Manufacturer's warranty does not apply. Amikon Limited is not an authorized distributor, dealer, or representative of the products displayed on this website. All product names, trademarks, brands, and logos used on this website are the property of their respective owners. The description, explanation, or sale of products with these names, trademarks, brands, and logos is for identification purposes only and is not intended to indicate any association with or authorization from any rights holder.
Product

Product Browsing History