Close Menu
Get Parts Quote
Name
Company *
WhatsApp / WeChat (For Faster Quote) *
Email *
Address
City
State / Province / Region
Zipcode
Country
Quantity *
Part Number *
Manufacturer
Preferred Condition
Additional Information
Cancel
In Stock
Fast Shipping Available
Schneider Electric LC1D95F7C
Schneider Electric LC1D95F7C
Schneider Electric LC1D95F7C
Schneider Electric LC1D95F7C
Schneider Electric LC1D95F7C
Schneider Electric LC1D95F7C
· Product image is representative; revision or series may vary. Contact us to request a specific version.
Ships by Sunday, October 11

LC1D95F7C

three-pole contactor

Shipping Information

  • For inventory products, we support same day shipping upon payment.
  • For urgent needs, we offer same-day shipping on most items for orders placed before 2:00 PM UTC+8 Simply mention your preferred next-day shipping when place the order, and your order will be prioritized to minimize downtime.
  • For indent items, typical turnaround is 1-3 weeks, depending on parts availability and scarcity.
Customs & Documentation
We prepare clear, order-specific documentation for every international shipment, including the commercial invoice, packing list and available product or compliance documents. Before dispatch, our logistics team confirms the consignee details, declared value, shipping terms and destination requirements with you. Tracking information is provided after shipment, helping your team prepare for import clearance with confidence.
Documents checked before dispatch · Shipment details confirmed · Global tracking provided
Payment
Payment is by bank wire only in RMB/CNY, GBP, EUR or USD. Amikon does not accept credit cards or provide credit terms. Cleared payment is required before shipment unless the written quotation expressly states otherwise.
Product Condition
Factory New These are new and current items that are procured directly from the manufacturer.
New In Sealed Package Parts are new. They have not been used and still have their original package seal intact.
New in Original Package These parts are new. The packages were not originally sealed by their original manufacturer.
Quantity
Mobile *
Country/Region *
E-mail *
Company
Content *
(gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Amikong please read our privacy policy.
  • 20+

    years in automation
  • ISO 9001

    certified quality system
  • 12 months

    amikon warranty
  • 2-hour reply

    from your account manager
  • Success Story

    solutions in action
PRODUCT DESCRIPTION

LC1D95F7C three-pole contactor

Schneider Electric LC1D95F7C is a three-pole contactor in the TeSys Deca contactors. It is used to switch and control the specified electrical load from the automation circuit.

Its documented configuration includes pole configuration of 3P, 3 NO, utilization categories of AC-1, AC-3, AC-3e, AC-4, ac-3 current of 95 A at 440 V, and ac-1 current of 125 A at 690 V. During operation, the three-pole contactor performs its assigned three-pole contactor function through the documented power, signal and communication interfaces.
ACTUAL APPLICATIONS

Application context for LC1D95F7C

Official manufacturer documentation supports these system uses when the complete TeSys Deca contactors configuration is verified.
  • 01 · AUTOMOTIVE

    Motor starter control panels

    Motor Switching SystemsConveyor motor switchingPump starter control
  • 02 · WATER & WASTEWATER

    Pump and blower starters

    Plant Motor SystemsHigh-service pump controlAeration blower switching
  • 03 · FOOD & BEVERAGE

    Packaging and process drives

    Machine Motor SystemsConveyor starter switchingMixer motor control

Technical specifications for LC1D95F7C

  • Product Model
    LC1D95F7C
  • Product Parameters
    three-pole contactor
  • In stock
    1 unit
  • Manufacturer
    Schneider Electric
  • Pole Configuration
    3P, 3 NO
  • Utilization Categories
    AC-1, AC-3, AC-3e, AC-4
  • AC-3 Current
    95 A at 440 V
  • AC-1 Current
    125 A at 690 V
  • Coil Voltage
    110 V AC 50/60 Hz
  • Operational Voltage
    Up to 690 V AC
  • Insulation Voltage
    1000 V
  • Impulse Withstand
    8 kV
  • Mechanical Durability
    4 million cycles
  • Electrical Durability
    1.2 million cycles at 95 A AC-3
  • Power Dissipation
    7.2 W per pole AC-3
  • Protection Degree
    IP20 front face
  • Operating Temperature
    -40 to +70 °C with derating
  • Mounting Support
    Rail or plate
View all additional

Alternative Names

LC1D95F7C TeSys Deca contactors three-pole contactor Schneider Electric three-pole contactor
SYSTEM & REPLACEMENT CHECK

Information needed before ordering

Three direct checks to secure your system integration and minimize ordering risks.

Information

System integration Replacement check Manuals & support
SYSTEM INTEGRATION

Match LC1D95F7C to the installed TeSys Deca contactors

Schneider Electric LC1D95F7C is a three-pole contactor for the TeSys Deca contactors. Its exact article suffix determines the supported interface, signal or communication function and the approved companion equipment.
Engineering should compare ac-1 current (125 A at 690 V), coil voltage (110 V AC 50/60 Hz) and operational voltage (Up to 690 V AC) with the installed system design. Confirm connector keying, addressing and configuration-tool support before connection.
Use the manufacturer documentation for the complete wiring and configuration sequence. Validate communication, signal conversion or control response with the connected equipment, then archive measured results and the final configuration with the asset record.

Features:

  • Exact identity: LC1D95F7C
  • Product class: three-pole contactor
  • Family: TeSys Deca contactors
The Schneider Electric LC1D95F7C requires documented system integration before energising the equipment.
REPLACEMENT CONTROL

Verify the complete LC1D95F7C identity before exchange

Replace LC1D95F7C only after matching the complete article code, three-pole contactor, installed TeSys Deca contactors role and documented hardware or firmware revision. Similar housings and related family numbers do not establish functional interchangeability.
Photograph the nameplate, keyed connectors, terminal numbering, cable routing, shields, earth points and adjacent modules. Export the applicable controller, HMI, drive or network configuration and record addresses, parameters and diagnostic messages before removal.
After fitting the verified article, restore the controlled configuration and check every affected signal or communication path. Review status indications and diagnostic buffers, run the documented functional test at a safe operating point and retain the final acceptance record.

Features:

  • Exact identity: LC1D95F7C
  • Product class: three-pole contactor
  • Family check: TeSys Deca contactors
The Schneider Electric LC1D95F7C requires documented replacement verification before energising the equipment.
DOCUMENTATION STATUS

Browse the Manuals, Datasheets, Official Documents, Links

Important Notice: Official documents are provided through manufacturer links. Accessories, manuals, cables, calibration data, software and certificates are included only when listed in the quotation.

Features:

  • Technical values prepared for LC1D95F7C
  • Schneider Electric TeSys Deca contactors references reviewed
  • Exact Schneider Electric identity required before service
Documentation for Schneider Electric LC1D95F7C must match the installed equipment; confirm document applicability before service.

Important notice

Manuals, software, firmware, cables, calibration data and accessories are included only when listed in the quotation. AMIKON is an independent supplier and is not affiliated with or authorised by the manufacturer.
This content has been produced using multiple sources. Takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
BUYER INFORMATION

Commercial terms without hidden steps

Your written quote confirms the product identity, price, availability, lead time, warranty and shipping terms before payment.
  • 01

    Shipping & delivery

    Dispatch
    Eligible stock: same / next day
    Carriers
    DHL, FedEx or UPS
    Ship from
    Xiamen, China
    Packed size
    8.4 × 12.5 × 12.7cm
    Shipping weight
    1.45 kg
  • 02

    Payment & customs

    Payment
    Bank transfer (T/T)
    Currencies
    USD · EUR · GBP · RMB
    Credit cards
    Not accepted
    HS reference
    8536490090
    Origin
    France
  • 03

    Warranty & returns

    Warranty
    12 months from AMIKON
    Inspection
    Label, condition and packing checks
    Returns
    Prior RMA authorisation required
    Compatibility
    Confirm before order
    OEM warranty
    Does not apply
Your written quote confirms the product identity, price, availability, lead time, warranty and shipping terms before payment.
  • Part checked

    Full suffix recorded
  • Condition checked

    Label and appearance
  • Packing checked

    Antistatic protection
  • Tracking supplied

    Established couriers
  • Sandy Lin

    Dedicated account manager · 15+ years
FREQUENTLY ASKED QUESTIONS

Questions buyers ask about LC1D95F7C

Direct answers about identity, compatibility, stock, warranty, payment and shipping.
  • How do I identify the correct LC1D95F7C?

    Confirm the complete LC1D95F7C nameplate, manufacturer, hardware revision and TeSys Deca contactors system context.
  • What should be checked before replacing LC1D95F7C?

    Compare the documented electrical ratings, signal or network interfaces, firmware and companion equipment for this three-pole contactor.
  • Can a similar TeSys Deca contactors article replace LC1D95F7C?

    Only after the complete article code, channel or port configuration, ratings and engineering configuration are confirmed.
  • What records should be saved before removal?

    Photograph connectors and labels, then save the relevant program, parameters, addresses and diagnostic state.
  • How should LC1D95F7C be inspected on receipt?

    Check the exact label, housing, terminals, keyed connectors and signs of transport or storage damage.
  • Which commissioning checks apply to LC1D95F7C?

    Verify supply and wiring, restore the approved configuration, review diagnostics and perform a controlled functional test.
  • What information is needed for a quotation?

    Provide LC1D95F7C, quantity, clear nameplate photos and the installed TeSys Deca contactors configuration.
  • What service evidence should be retained?

    Keep the connection record, parameter backup, measurements, diagnostic results and final acceptance record.
READY TO VERIFY YOUR PART?

Get a LC1D95F7C quote with price, lead time and revision check.

Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, drives and servo motors, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: Amikon Limited sells new and surplus products and develops channels for purchasing such products. Amikon Limited is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because Amikon Limited is not an authorized distributor of this product, the Original Manufacturer's warranty does not apply. Amikon Limited is not an authorized distributor, dealer, or representative of the products displayed on this website. All product names, trademarks, brands, and logos used on this website are the property of their respective owners. The description, explanation, or sale of products with these names, trademarks, brands, and logos is for identification purposes only and is not intended to indicate any association with or authorization from any rights holder.
Product

Product Browsing History