Siemens 3RM1007-1AA04
· Product image is representative; revision or series may vary. Contact us to request a specific version.
Ships by Thursday, November 26

3RM1007-1AA04

Hybrid direct motor starter

Shipping Information

  • For inventory products, we support same day shipping upon payment.
  • For urgent needs, we offer same-day shipping on most items for orders placed before 2:00 PM UTC+8 Simply mention your preferred next-day shipping when place the order, and your order will be prioritized to minimize downtime.
  • For indent items, typical turnaround is 1-3 weeks, depending on parts availability and scarcity.
Customs & Documentation
We prepare clear, order-specific documentation for every international shipment, including the commercial invoice, packing list and available product or compliance documents. Before dispatch, our logistics team confirms the consignee details, declared value, shipping terms and destination requirements with you. Tracking information is provided after shipment, helping your team prepare for import clearance with confidence.
Documents checked before dispatch · Shipment details confirmed · Global tracking provided
Payment
Payment is by bank wire only in RMB/CNY, GBP, EUR or USD. Amikon does not accept credit cards or provide credit terms. Cleared payment is required before shipment unless the written quotation expressly states otherwise.
Product Condition
Factory New These are new and current items that are procured directly from the manufacturer.
New In Sealed Package Parts are new. They have not been used and still have their original package seal intact.
New in Original Package These parts are new. The packages were not originally sealed by their original manufacturer.
Quantity
Mobile *
Country/Region *
E-mail *
Company
Content *
(gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Amikong please read our privacy policy.
  • 20+

    years in automation
  • ISO 9001

    certified quality system
  • 12 months

    amikon warranty
  • 2-hour reply

    from your account manager
  • Success Story

    solutions in action
PRODUCT DESCRIPTION

3RM1007-1AA04 Hybrid direct motor starter

Siemens 3RM1007-1AA04 is a SIRIUS 3RM1 direct-on-line motor starter with hybrid switching and electronic overload protection. Its 1.6-7 A adjustment range covers three-phase motors from 0.55 to 3 kW at 400 V. Screw terminals connect the main and control circuits.

The three-pole main circuit operates at 48-500 V AC, and the control circuit uses 24 V DC. An auxiliary changeover contact and electronic OUT signal provide status outputs. Continuous-current capability decreases above 40 C to 4.6 A at 60 C; short-circuit interruption relies on the coordinated upstream protection.
ACTUAL APPLICATIONS

Application fields for 3RM1007-1AA04

The broad fields for 3RM1007-1AA04 include buildings, logistics, water.
  • 01 · BUILDINGS

    Commercial Buildings and Public Premises

    Commercial Premises and Indoor EnvironmentsPublic Buildings and Municipal Premises
  • 02 · LOGISTICS

    Industrial Warehousing and Freight Distribution

    Industrial Warehousing and Regional FreightCommercial Distribution and Transport Logistics
  • 03 · WATER

    Public Water and Industrial Supply

    Public Water Supply and SanitationIndustrial Water and Municipal Reuse

Technical specifications for 3RM1007-1AA04

  • Product Model
    3RM1007-1AA04
  • Product Parameters
    Hybrid direct motor starter
  • In stock
    1 unit
  • Manufacturer
    Siemens
  • Motor current adjustment
    1.6 to 7 A
  • Motor power at 400 V
    0.55 to 3 kW
  • Main operating voltage
    48 to 500 V AC
  • Control voltage
    24 V DC; 19.2 to 30 V
  • Connection terminals
    Screw terminals
  • Main switching poles
    3, hybrid contacts
  • Starting current capability
    56 A maximum
  • Auxiliary changeover contact
    1 CO
  • Auxiliary AC-15 contact
    3 A maximum at 230 V
  • Auxiliary DC-13 contact
    1 A maximum at 24 V
  • Digital command current
    11 mA for signal 1
  • Electronic OUT signal
    24 V DC, 15 mA
  • Intrinsic short-circuit interruption
    Not provided; external coordination required
  • Rated impulse withstand
    6 kV
  • Current derating at 60 C
    4.6 A
View all additional

Alternative Names

3RM1007-1AA04 SIRIUS 3RM1 Compact Starters Hybrid direct motor starter
SYSTEM & REPLACEMENT CHECK

Information needed before ordering

Three direct checks to secure your system integration and minimize ordering risks.

Information

System integration Replacement check Manuals & support
SYSTEM INTEGRATION

Integrate 3RM1007-1AA04 within SIRIUS 3RM1 Compact Starters

Match the 3RM1 starter to a motor within the 1.6-7 A range and the permissible AC voltage. Use 24 V DC control and retain the screw-terminal construction in the panel wiring design.
Select external short-circuit protection and the required overload setting using the manufacturer coordination data. Include ambient-temperature derating, starting-current demand and ventilation spacing in the feeder design.
Test command inputs, the electronic OUT indication and the auxiliary contact independently. Confirm controlled motor starting and stopping and document the verified overload and fault-feedback behavior.

Features:

  • Motor current adjustment: 1.6 to 7 A
  • Motor power at 400 V: 0.55 to 3 kW
  • SIRIUS 3RM1 Compact Starters
Use 3RM1007-1AA04 only within the documented SIRIUS 3RM1 Compact Starters arrangement and applicable installation instructions.
INTERCHANGEABILITY

Replace 3RM1007-1AA04 within SIRIUS 3RM1 Compact Starters

Record the 3RM1 current setting, main wiring, control supply and status-contact allocation. Identify the external protective device because the starter itself does not interrupt short circuits.
Isolate the feeder and control supply before removing the screw-terminal connections. Inspect terminals and mounting retention, then restore the same conductor assignments and overload setting.
Check command timing and feedback with the motor safely controlled. Verify normal running current against the ambient derating and retain the final feeder settings in the maintenance record.

Features:

  • 3RM1007-1AA04 complete order code
  • Current derating at 60 C: 4.6 A
  • Retain the documented SIRIUS 3RM1 Compact Starters connection arrangement
Use 3RM1007-1AA04 only within the documented SIRIUS 3RM1 Compact Starters arrangement and applicable installation instructions.
DOCUMENTATION STATUS

Browse the Manuals, Datasheets, Official Documents, Links

Important Notice: The linked files are Amikong-hosted reference documents. Match their product identity and scope to the supplied assembly, and consult the applicable manufacturer instructions before use. Accessories and additional documents are included only when expressly listed in the quotation.

Features:

  • Exact-model technical data for 3RM1007-1AA04
  • Document applicability checked against the complete identity
  • Directory links by subcategory and brand
Documentation for 3RM1007-1AA04 must match the installed product identity and supplied configuration.

Important notice

Manuals, software, firmware, cables, calibration data and accessories are included only when listed in the quotation. AMIKON is an independent supplier and is not affiliated with or authorised by the manufacturer.
This content has been produced using multiple sources. Takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
BUYER INFORMATION

Commercial terms without hidden steps

Your written quote confirms the product identity, price, availability, lead time, warranty and shipping terms before payment.
  • 01

    Shipping & delivery

    Dispatch
    Eligible stock: same / next day
    Carriers
    DHL, FedEx or UPS
    Ship from
    Xiamen, China
    Product size
    2.25 x 10.00 x 14.16 cm
    Net weight
    0.32 kg
  • 02

    Payment & customs

    Payment
    Bank transfer (T/T)
    Currencies
    USD · EUR · GBP · RMB
    Credit cards
    Not accepted
    HS reference
    8537109090
    Origin
    Germany
  • 03

    Warranty & returns

    Warranty
    12 months from AMIKON
    Inspection
    Label, condition and packing checks
    Returns
    Prior RMA authorisation required
    Compatibility
    Confirm before order
    OEM warranty
    Does not apply
Your written quote confirms the product identity, price, availability, lead time, warranty and shipping terms before payment.
  • Part checked

    Full suffix recorded
  • Condition checked

    Label and appearance
  • Packing checked

    Antistatic protection
  • Tracking supplied

    Established couriers
  • Sandy Lin

    Dedicated account manager · 15+ years
FREQUENTLY ASKED QUESTIONS

Questions buyers ask about 3RM1007-1AA04

Direct answers about identity, compatibility, stock, warranty, payment and shipping.
  • Does 3RM1007-1AA04 contain a short-circuit breaker?

    No. 3RM1007-1AA04 combines hybrid starting and electronic overload protection but requires the documented external short-circuit coordination.
  • How far ca 3RM1007-1AA04 overload current be adjusted?

    3RM1007-1AA04 covers 1.6-7 A. Match the motor current, starting duty and ambient derating when setting the overload value.
  • Is the 3RM1007-1AA04 control input the same voltage as the main circuit?

    No. 3RM1007-1AA04 uses 24 V DC control with a 19.2-30 V permissible range; the main circuit is rated 48-500 V AC.
  • How much current may 3RM1007-1AA04 carry at 60 C?

    The 3RM1007-1AA04 data sheet derates continuous current to 4.6 A at 60 C, compared with 7 A at 40 C.
  • Which status circuits are available on 3RM1007-1AA04?

    3RM1007-1AA04 provides an electronic OUT signal rated 24 V DC/15 mA and one auxiliary changeover contact with separate AC-15 and DC-13 ratings.
  • What should be checked after a 3RM1007-1AA04 starter exchange?

    Restore the 3RM1007-1AA04 overload setting and terminal assignments, then test command response, status feedback and motor behavior under a safe controlled load.
  • Which terminal style must a 3RM1007-1AA04 spare quotation retain?

    Specify 3RM1007-1AA04 with screw terminals and 24 V DC control. Include the 1.6-7 A adjustment range rather than only the 3RM1 family name.
  • Should distributors quote 3RM1007-1AA04 as a complete protected feeder?

    No. The 3RM1007-1AA04 offer must distinguish the starter from any external short-circuit device, connector or mounting accessory required for the complete feeder.
READY TO VERIFY YOUR PART?

Get a 3RM1007-1AA04 quote with price, lead time and revision check.

Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, drives and servo motors, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: Amikon Limited sells new and surplus products and develops channels for purchasing such products. Amikon Limited is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because Amikon Limited is not an authorized distributor of this product, the Original Manufacturer's warranty does not apply. Amikon Limited is not an authorized distributor, dealer, or representative of the products displayed on this website. All product names, trademarks, brands, and logos used on this website are the property of their respective owners. The description, explanation, or sale of products with these names, trademarks, brands, and logos is for identification purposes only and is not intended to indicate any association with or authorization from any rights holder.