Vibro-Meter VM600 IOCN 200-566-000-112
Vibro-Meter VM600 IOCN 200-566-000-112
Vibro-Meter VM600 IOCN 200-566-000-112
Vibro-Meter VM600 IOCN 200-566-000-112
Vibro-Meter VM600 IOCN 200-566-000-112
Vibro-Meter VM600 IOCN 200-566-000-112
· Product image is representative; revision or series may vary. Contact us to request a specific version.

VM600 IOCN 200-566-000-112

CPUM Input and Output Card

Shipping Information

  • For inventory products, we support same day shipping upon payment.
  • For urgent needs, we offer same-day shipping on most items for orders placed before 2:00 PM UTC+8 Simply mention your preferred next-day shipping when place the order, and your order will be prioritized to minimize downtime.
  • For indent items, typical turnaround is 1-3 weeks, depending on parts availability and scarcity.
Customs & Documentation
We prepare clear, order-specific documentation for every international shipment, including the commercial invoice, packing list and available product or compliance documents. Before dispatch, our logistics team confirms the consignee details, declared value, shipping terms and destination requirements with you. Tracking information is provided after shipment, helping your team prepare for import clearance with confidence.
Documents checked before dispatch · Shipment details confirmed · Global tracking provided
Payment
Payment is by bank wire only in RMB/CNY, GBP, EUR or USD. Amikon does not accept credit cards or provide credit terms. Cleared payment is required before shipment unless the written quotation expressly states otherwise.
Product Condition
Factory New These are new and current items that are procured directly from the manufacturer.
New In Sealed Package Parts are new. They have not been used and still have their original package seal intact.
New in Original Package These parts are new. The packages were not originally sealed by their original manufacturer.
Quantity
Mobile *
Country/Region *
E-mail *
Company
Content *
(gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Amikong please read our privacy policy.
  • 20+

    years in automation
  • ISO 9001

    certified quality system
  • 12 months

    amikon warranty
  • 2-hour reply

    from your account manager
  • Success Story

    solutions in action
PRODUCT DESCRIPTION

VM600 IOCN 200-566-000-112 CPUM Input and Output Card

Vibro-Meter VM600 IOCN 200-566-000-112 is the rear input and output card used with the VM600 CPUM. Its part number belongs to the standard Ethernet-redundant IOCN variant described in the manufacturer ordering table.

The IOCN brings CPUM interfaces out to the rear of the rack. Its documented interface options include RJ45 Ethernet and configurable serial paths, with serial routing dependent on the selected jumper configuration.
BEFORE YOU BUY

Confirm the complete VM600 IOCN 200-566-000-112 identity

ACTUAL APPLICATIONS

Application fields for VM600 IOCN 200-566-000-112

These broad application fields reflect the documented function and technical characteristics of VM600 IOCN 200-566-000-112.
  • 01 · POWER

    Thermal and Hydroelectric Power

    Thermal generation and rotating asset reliabilityHydroelectric generation and mechanical condition assessment
  • 02 · OIL & GAS

    Petroleum and Gas Reliability

    Offshore petroleum and natural gas reliabilityOnshore gas treatment and condition oversight
  • 03 · METALS & MINING

    Metallurgy and Mineral Extraction

    Ferrous metallurgy and mechanical condition assessmentMineral extraction and vibration risk management

Technical specifications for VM600 IOCN 200-566-000-112

  • Product Model
    VM600 IOCN 200-566-000-112
  • Spare Model
    200-566-000-112
  • Product Parameters
    CPUM Input and Output Card
  • In stock
    9 units
  • Manufacturer
    Vibro-Meter
  • Mating front card
    VM600 CPUM
  • Redundancy variant
    Standard Ethernet-redundant IOCN
  • Ethernet interface standard
    10/100BASE-TX
  • Ethernet interface count
    2
  • Primary Ethernet data rate
    Up to 100 Mbps
  • Secondary Ethernet data rate
    Up to 10 Mbps
  • Ethernet segment length
    Up to 100 m between devices
  • Ethernet connectors
    Ports 1 and 2: female 8P8C RJ45
  • Rear serial connector
    RS: female 6P6C RJ12 / RJ25
  • Secondary Ethernet protocol
    Modbus TCP
  • Interface routing selection
    Jumpers on the CPUM and IOCN cards
  • Operating temperature
    -20 to +65 °C
  • Storage temperature
    -25 to +80 °C
  • Ambient humidity
    0 to 90% RH, non-condensing
  • Power source
    VM600 rack power supply
View all additional
SYSTEM & REPLACEMENT CHECK

Information needed before ordering

Three direct checks to secure your system integration and minimize ordering risks.

Information

System integration Replacement check Manuals & support
SYSTEM INTEGRATION

Integrate VM600 IOCN 200-566-000-112 within VM600

Vibro-Meter VM600 IOCN 200-566-000-112 is the rear input and output card used with the VM600 CPUM. Its part number belongs to the standard Ethernet-redundant IOCN variant described in the manufacturer ordering table. The IOCN is the rear companion card for the VM600 CPUM.
The manufacturer lists pattern 200-566-000-1Hh as the standard Ethernet-redundant IOCN. The IOCN documentation shows RJ45 Ethernet connections.
The IOCN brings CPUM interfaces out to the rear of the rack. Its documented interface options include RJ45 Ethernet and configurable serial paths, with serial routing dependent on the selected jumper configuration. The IOCN supports documented RS-232 or RS-485 paths according to the applicable configuration.

Features:

  • Ordering family pattern: 200-566-000-1Hh
  • Network redundancy variant: Standard Ethernet-redundant IOCN
  • VM600
Use VM600 IOCN 200-566-000-112 only within the documented VM600 arrangement and applicable installation instructions.
INTERCHANGEABILITY

Replace VM600 IOCN 200-566-000-112 within VM600

Record the complete hardware marking, serial jumper positions, rear cable positions and mating CPUM identity. Check the configured Ethernet paths and confirm that each serial link uses the same interface and routing as before.
The IOCN is a separate rear card. List the CPUM explicitly if both are required. The ordering table defines the corresponding Hh positions as hardware version digits.
After fitting VM600 IOCN 200-566-000-112, compare the restored arrangement with the approved equipment record. Verify the affected functions against the applicable VM600 maintenance documentation before returning the equipment to use.

Features:

  • Ordering family pattern: 200-566-000-1Hh
  • Network redundancy variant: Standard Ethernet-redundant IOCN
  • VM600
Use VM600 IOCN 200-566-000-112 only within the documented VM600 arrangement and applicable installation instructions.
DOCUMENTATION STATUS

Browse the Manuals, Datasheets, Official Documents, Links

Important Notice: The linked files are Amikong-hosted reference documents. Match their product identity and scope to the supplied assembly, and consult the applicable manufacturer instructions before use. Accessories and additional documents are included only when expressly listed in the quotation.

Features:

  • Exact-model technical data for VM600 IOCN 200-566-000-112
  • Document applicability checked against the complete identity
  • Directory links by subcategory and brand
Documentation for VM600 IOCN 200-566-000-112 must match the installed product identity and supplied configuration.

Important notice

Manuals, software, firmware, cables, calibration data and accessories are included only when listed in the quotation. AMIKON is an independent supplier and is not affiliated with or authorised by the manufacturer.
This content has been produced using multiple sources. Takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
BUYER INFORMATION

Commercial terms without hidden steps

Your written quote confirms the product identity, price, availability, lead time, warranty and shipping terms before payment.
  • 01

    Shipping & delivery

    Dispatch
    Confirm with quotation
    Carriers
    DHL, FedEx or UPS
    Ship from
    Xiamen, China
    Product size
    2.00 x 12.40 x 26.10 cm
    Net weight
    0.14 kg
  • 02

    Payment & customs

    Payment
    Bank transfer (T/T)
    Currencies
    USD · EUR · GBP · RMB
    Credit cards
    Not accepted
    HS reference
    9031900090
    Origin
    Switzerland
  • 03

    Warranty & returns

    Warranty
    12 months from AMIKON
    Inspection
    Label, condition and packing checks
    Returns
    Prior RMA authorisation required
    Compatibility
    Confirm before order
    OEM warranty
    Does not apply
Your written quote confirms the product identity, price, availability, lead time, warranty and shipping terms before payment.
  • Part checked

    Full suffix recorded
  • Condition checked

    Label and appearance
  • Packing checked

    Antistatic protection
  • Tracking supplied

    Established couriers
  • Sandy Lin

    Dedicated account manager · 15+ years
FREQUENTLY ASKED QUESTIONS

Questions buyers ask about VM600 IOCN 200-566-000-112

Direct answers about identity, compatibility, stock, warranty, payment and shipping.
  • Which front card works with VM600 IOCN 200-566-000-112?

    The IOCN is the rear companion card for the VM600 CPUM.
  • How does VM600 IOCN 200-566-000-112 identify its Ethernet variant?

    The manufacturer lists pattern 200-566-000-1Hh as the standard Ethernet-redundant IOCN.
  • Which Ethernet connector is documented for VM600 IOCN 200-566-000-112?

    The IOCN documentation shows RJ45 Ethernet connections.
  • Which serial interface can VM600 IOCN 200-566-000-112 expose?

    The IOCN supports documented RS-232 or RS-485 paths according to the applicable configuration.
  • What should be recorded before removing VM600 IOCN 200-566-000-112?

    Record the complete hardware marking, serial jumper positions, rear cable positions and mating CPUM identity.
  • How can maintenance test VM600 IOCN 200-566-000-112 after fitting it?

    Check the configured Ethernet paths and confirm that each serial link uses the same interface and routing as before.
  • Does a quote for VM600 IOCN 200-566-000-112 include the CPUM?

    The IOCN is a separate rear card. List the CPUM explicitly if both are required.
  • What does the trailing 12 represent on VM600 IOCN 200-566-000-112?

    The ordering table defines the corresponding Hh positions as hardware version digits.
READY TO VERIFY YOUR PART?

Get a VM600 IOCN 200-566-000-112 quote with price, lead time and revision check.

Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, drives and servo motors, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: Amikon Limited sells new and surplus products and develops channels for purchasing such products. Amikon Limited is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because Amikon Limited is not an authorized distributor of this product, the Original Manufacturer's warranty does not apply. Amikon Limited is not an authorized distributor, dealer, or representative of the products displayed on this website. All product names, trademarks, brands, and logos used on this website are the property of their respective owners. The description, explanation, or sale of products with these names, trademarks, brands, and logos is for identification purposes only and is not intended to indicate any association with or authorization from any rights holder.
Product

Product Browsing History