Duplexed Field Control Unit
For Vnet/IP and FIO, for 19-inch Rack Mountable
100–120 V AC power supply
220–240 V AC power supply
Basic type
LFS1500 Control Function for Field Control Station (for Vnet/IP and FIO)
Current Input Module
16, isolated
4 to 20 mA
270 Ω (20 mA) to 350 Ω (4 mA)
±16 µA
230 mA (5 V DC), 540 mA (24 V DC)
Power Supply Module
Power Supply Module
Two modules in case of
dual-redundant configuration.
Power supply to the I/O modules
and supply power to the transmitters
The power supply terminals use M4 screws
Power Supply Module
Input Voltage: 100-120V or 200-240V
Output Voltage: 24V
Output Current :5A
Power Output: Up to 120W
Operating Temperature: -10°C to +55°C
Storage Temperature: -20°C to +70°C
Advanced Valve Positioner
Linear or rotary motion control valve
±0.5% of span (including linkages)
0.3% of span *1
Digital: FOUNDATION fieldbus
Supply voltage: 9 to 32V DC
Supply current: 17 mA (max)
140 to 700 kPa (20 to 100 psi)
0.32 Nm3/h (0.178 SCFM) at 140 kPa (20 psi) of air supply
6.6 Nm3/h (4.1 SCFM) at 140 kPa (20 psi) of air supply
-40 to 85 deg C (-40 to 185 deg F)
Digital Output Module
Number of outputs 16-channel, module isolation
Output voltage 24 V DC
Output voltage drop 1 V maximum
External power supply rating 24 V DC, 3.4 A minimum
Maximum leak current at output off status 1.6 mA
Output format Current source
Minimum load current 35 mA
Load resistance range 120 to 685 Ω
Output response time 30 ms maximum
Optical ESB Bus RepeaterSlave Module
Optical ESB Bus RepeaterSlave Module
Star type connection Chain type connection Available
for both star and chain type connection
Maximum two
Maximum 5 km (total two stages)
In case of Vnet/IP system with the R1.03 or later
the total distance of two stagesis maximum 10 km
Current consumption: 0.5 A
Optical ESB Bus Repeater Slave Module
ESB Bus optical transport function
Star type connection
Chain type connection
Maximum two
Maximum 5 km (total two stages)
Current consumption: 0.5 A
Optical ESB Bus Repeater Module
Function: ESB Bus optical transport function
Connection method: Star type connection
Chain type connection
Available for both star and chain type connection.
Number of connecting stage: Maximum two
Transmission distance: Maximum 5 km (total two stages)
In case of Vnet/IP system with the R1.03 or later,
the total distance of two stagesis maximum 10 km.
Current consumption: 0.5 A
Optical ESB Bus Repeater Module
ESB Bus optical transport function
Connection method:
Star type connection
Chain type connection
Available for both star and chain type connection.
Number of connecting stage: Maximum two
Transmission distance: Maximum 5 km (total two stages)
In case of Vnet/IP system with the R1.03 or later,
the total distance of two stagesis
maximum 10 km.
Current consumption: 0.5 A
Optical ESB Bus Repeater Module
Product No. : SNT401-13
Product Type : Optical ESB Bus Repeater Master Module
1 - with no explosion protection
3 - ISA Standard G3 and temperature (-20 to 70°C)
CU1N - Connector unit for ESB Bus
Copyright Notice © 2004-2024 amikong.com All rights reserved
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.