Yokogawa SNT401-13 S1
Yokogawa SNT401-13 S1
Yokogawa SNT401-13 S1
Yokogawa SNT401-13 S1
Yokogawa SNT401-13 S1
Yokogawa SNT401-13 S1
· Product image is representative; revision or series may vary. Contact us to request a specific version.
Ships by Saturday, November 14

SNT401-13 S1

Optical ESB Master Module

Shipping Information

  • For inventory products, we support same day shipping upon payment.
  • For urgent needs, we offer same-day shipping on most items for orders placed before 2:00 PM UTC+8 Simply mention your preferred next-day shipping when place the order, and your order will be prioritized to minimize downtime.
  • For indent items, typical turnaround is 1-3 weeks, depending on parts availability and scarcity.
Customs & Documentation
We prepare clear, order-specific documentation for every international shipment, including the commercial invoice, packing list and available product or compliance documents. Before dispatch, our logistics team confirms the consignee details, declared value, shipping terms and destination requirements with you. Tracking information is provided after shipment, helping your team prepare for import clearance with confidence.
Documents checked before dispatch · Shipment details confirmed · Global tracking provided
Payment
Payment is by bank wire only in RMB/CNY, GBP, EUR or USD. Amikon does not accept credit cards or provide credit terms. Cleared payment is required before shipment unless the written quotation expressly states otherwise.
Product Condition
Factory New These are new and current items that are procured directly from the manufacturer.
New In Sealed Package Parts are new. They have not been used and still have their original package seal intact.
New in Original Package These parts are new. The packages were not originally sealed by their original manufacturer.
Quantity
Mobile *
Country/Region *
E-mail *
Company
Content *
(gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Amikong please read our privacy policy.
  • 20+

    years in automation
  • ISO 9001

    certified quality system
  • 12 months

    amikon warranty
  • 2-hour reply

    from your account manager
  • Success Story

    solutions in action
PRODUCT DESCRIPTION

SNT401-13 S1 Optical ESB Master Module

Yokogawa SNT401-13 S1 is an optical ESB bus repeater master module for ProSafe-RS. It converts the electrical ESB connection from a safety control unit or safety node into an optical link, allowing separated nodes to remain connected through a supported star or chain arrangement. The SNT401 master works with the corresponding SNT501 slave rather than functioning as a general-purpose Ethernet converter.

The SNT401/SNT501 specification lists 0.5 A current consumption and a maximum of two optical stages. Standard total transmission distance is up to 5 km; the 10 km two-stage allowance requires the documented Vnet/IP R1.03 or later arrangement. A duplex pair occupies consecutive slots, with bus 1 in the odd slot and bus 2 in the even slot.
ACTUAL APPLICATIONS

Application fields for SNT401-13 S1

These broad application fields reflect the documented function and technical characteristics of SNT401-13 S1.
  • 01 · OIL & GAS

    Onshore Petroleum and Offshore Natural Gas

    Onshore petroleum and associated natural gasOffshore natural gas and petroleum condensates
  • 02 · CHEMICALS

    Industrial Chemistry and Basic Petrochemical Resources

    Industrial chemistry and basic petrochemical resourcesOrganic chemistry and inorganic chemical resources
  • 03 · POWER GENERATION

    Thermal Power and Renewable Energy

    Conventional thermal power and hydroelectric generationWind energy and renewable electricity generation

Technical specifications for SNT401-13 S1

  • Product Model
    SNT401-13 S1
  • Spare Model
    SNT401-13
  • Product Parameters
    Optical ESB Master Module
  • In stock
    1 unit
  • Manufacturer
    Yokogawa
  • Current consumption
    0.5 A
  • Connection topologies
    Star and chain
  • Maximum optical stages
    2
  • Total optical distance
    Up to 5 km across two stages
  • Minimum SENG revision
    R1.02
  • Minimum SCS revision
    R1.02
  • Duplex bus 1 slot
    Odd-numbered slot
  • Duplex bus 2 slot
    Adjacent even-numbered slot
  • Matched optical slave
    SNT501 with final suffix 3
  • Optical connector
    LC; IEC 61754-20
  • Optical fiber specification
    Quartz single-mode; JIS C 6835 SSMA-9.3/125 or IEC 60793-2-50 B1.1
  • Optical fiber cores
    2 cores
  • Optical wavelength
    1.3 micrometres
  • Permissible optical path loss
    0 to 16 dB
  • Laser safety class
    Class 1; IEC 60825
View all additional

Alternative Names

SNT401-13 S1 ProSafe-RS optical ESB Optical ESB Master Module
SYSTEM & REPLACEMENT CHECK

Information needed before ordering

Three direct checks to secure your system integration and minimize ordering risks.

Information

System integration Replacement check Manuals & support
SYSTEM INTEGRATION

Integrate SNT401-13 S1 within ProSafe-RS optical ESB

Connect the master-side electrical ESB cable to the applicable SEC401, SEC402 or SSB401 interface. The opposite optical endpoint must be the matching SNT501 type; the terminal digit 3 pairing is shown separately from the F pairing in the manufacturer selection table.
Plan the optical path as one or two stages and calculate the total path rather than treating the distance allowance as a per-stage figure. The general SNT401/SNT501 limit is 5 km; the longer two-stage arrangement is conditional on the Vnet/IP revision stated in the specification.
For duplex ESB transport, install the two repeaters in consecutive slots with the prescribed odd/even bus assignment. On SNT10D at 60 to 70 C, observe the two-slot clearance beside the power supply and between repeater sets. SENG and SCS R1.02 are the minimum listed revisions.

Features:

  • Current consumption: 0.5 A
  • Connection topologies: Star and chain
  • ProSafe-RS optical ESB
Use SNT401-13 S1 only within the documented ProSafe-RS optical ESB arrangement and applicable installation instructions.
INTERCHANGEABILITY

Replace SNT401-13 S1 within ProSafe-RS optical ESB

Record the complete SNT401-13 S1 label and the slave endpoint before removal. A master must remain a master, and the optical pairing table must match the installed final suffix; selecting an SNT501 solely because its enclosure looks similar reverses the link role.
Retain the bus 1 and bus 2 slot positions and identify whether the electrical ESB connector unit includes a terminator. The /CU1N and /CU1T arrangements are different accessories. The absence of an option on the order line must not be interpreted as either accessory being supplied.
After replacement, confirm both ESB paths and the actual remote-node status in the approved maintenance procedure. Review the installed SENG/SCS revision, total optical length and high-temperature clearances before accepting the restored redundant arrangement.

Features:

  • SNT401-13 S1 complete suffix
  • Matched optical slave: SNT501 with final suffix 3
  • Master/slave role and installed optical paths retained
Use SNT401-13 S1 only within the documented ProSafe-RS optical ESB arrangement and applicable installation instructions.
DOCUMENTATION STATUS

Browse the Manuals, Datasheets, Official Documents, Links

Important Notice: The linked files are Amikong-hosted reference documents. Match their product identity and scope to the supplied assembly, and consult the applicable manufacturer instructions before use. Accessories and additional documents are included only when expressly listed in the quotation.

Features:

  • Exact-model technical data for SNT401-13 S1
  • Document applicability checked against the complete identity
  • Directory links by subcategory and brand
Documentation for SNT401-13 S1 must match the installed product identity and supplied configuration.

Important notice

Manuals, software, firmware, cables, calibration data and accessories are included only when listed in the quotation. AMIKON is an independent supplier and is not affiliated with or authorised by the manufacturer.
This content has been produced using multiple sources. Takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
BUYER INFORMATION

Commercial terms without hidden steps

Your written quote confirms the product identity, price, availability, lead time, warranty and shipping terms before payment.
  • 01

    Shipping & delivery

    Dispatch
    Eligible stock: same / next day
    Carriers
    DHL, FedEx or UPS
    Ship from
    Xiamen, China
    Product size
    3.28 x 13.00 x 14.25 cm
    Net weight
    0.30 kg
  • 02

    Payment & customs

    Payment
    Bank transfer (T/T)
    Currencies
    USD · EUR · GBP · RMB
    Credit cards
    Not accepted
    HS reference
    8517622990
    Origin
    Japan
  • 03

    Warranty & returns

    Warranty
    12 months from AMIKON
    Inspection
    Label, condition and packing checks
    Returns
    Prior RMA authorisation required
    Compatibility
    Confirm before order
    OEM warranty
    Does not apply
Your written quote confirms the product identity, price, availability, lead time, warranty and shipping terms before payment.
  • Part checked

    Full suffix recorded
  • Condition checked

    Label and appearance
  • Packing checked

    Antistatic protection
  • Tracking supplied

    Established couriers
  • Sandy Lin

    Dedicated account manager · 15+ years
FREQUENTLY ASKED QUESTIONS

Questions buyers ask about SNT401-13 S1

Direct answers about identity, compatibility, stock, warranty, payment and shipping.
  • Does SNT401-13 S1 connect to SEC401 directly?

    SNT401-13 S1 accepts the electrical ESB connection from SEC401 or SEC402 on the safety control unit, or SSB401 on an applicable safety node.
  • Which slave suffix matches SNT401-13 S1?

    The selection table pairs the final 3 version of SNT401-13 S1 with an SNT501 final 3 version; the F pairing is a separate arrangement.
  • Can SNT401-13 S1 span 10 km in any installation?

    No. The SNT401-13 S1 family specification allows 10 km total across two stages only for the stated Vnet/IP R1.03-or-later configuration; the general two-stage limit is 5 km.
  • Where does bus 1 belong when duplicating SNT401-13 S1?

    For a duplex SNT401-13 S1 pair, bus 1 occupies the odd-numbered slot and bus 2 the next even-numbered slot.
  • What is the minimum software revision for SNT401-13 S1?

    The SNT401/SNT501 general specification lists SENG R1.02 and SCS R1.02 as the minimum revisions applicable to SNT401-13 S1.
  • Does SNT401-13 S1 include the ESB terminator?

    The complete option is decisive: /CU1N identifies the connector unit without a terminator, while /CU1T includes the terminator. The bare SNT401-13 S1 designation does not confirm either supplied option.
  • What should a distributor specify when quoting SNT401-13 S1?

    Quote SNT401-13 S1 in full, identify the required connector-unit option and state whether one module or a duplex pair is required. Availability and delivery belong on the written quotation.
  • Which receiving details distinguish a correct SNT401-13 S1 delivery?

    For SNT401-13 S1, compare the full label and style, master role, optical endpoint suffix and separately ordered connector unit against the accepted quotation; inspect the optical ports before installation.
READY TO VERIFY YOUR PART?

Get a SNT401-13 S1 quote with price, lead time and revision check.

Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, drives and servo motors, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: Amikon Limited sells new and surplus products and develops channels for purchasing such products. Amikon Limited is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because Amikon Limited is not an authorized distributor of this product, the Original Manufacturer's warranty does not apply. Amikon Limited is not an authorized distributor, dealer, or representative of the products displayed on this website. All product names, trademarks, brands, and logos used on this website are the property of their respective owners. The description, explanation, or sale of products with these names, trademarks, brands, and logos is for identification purposes only and is not intended to indicate any association with or authorization from any rights holder.